BMC GTADP-4860-C user manual

User manual for the device BMC GTADP-4860-C

Device: BMC GTADP-4860-C
Category: Heat Pump
Manufacturer: BMC
Size: 2.57 MB
Added : 5/22/2014
Number of pages: 54
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for BMC GTADP-4860-C. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with BMC GTADP-4860-C.

For your convenience

If looking through the BMC GTADP-4860-C user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual BMC GTADP-4860-C on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual BMC GTADP-4860-C to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
BMC GTADP-4860-C User manual - Online PDF
Advertisement
« Page 1 of 54 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual BMC GTADP-4860-C but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to BMC GTADP-4860-C. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

WATER SOURCE HEAT PUMP MODELS:
GTB1-A Blower Section
INSTALLATION
GTA3600UD1AA Coil Section
INSTRUCTIONS
GTA4860UD1AA Coil Section
GTADP-3642-B Coil Section
GTADP-3642-C Coil Section
GTADP-4860-C Coil Section
GTC36S2-ADCX Compressor Section
GTC48S2-ADCX Compressor Section
GTC60S2-ADCX Compressor Section
GTC36S2-ADNX Compressor Section
GTC48S2-ADNX Compressor Section
GTC60S2-ADNX Compressor Section
MIS-2830
Earth Loop Fluid
Temperatures 25° - 110°
Ground Water Temperatures 45° - 75

Summary of the content on the page No. 2

CONTENTS Getting Other Informations and Publications ..............3 Sequence of Operation Blower ............................................................................ 38 General Information Geo-Trio (GT Series) Part / Full Load Cooling .......................................................... 38 Water Source Nomenclature .................................................... 4 Part / Full Load Heating .......................................................... 38 Blower Conversion & Line

Summary of the content on the page No. 3

GETTING OTHER INFORMATION AND PUBLICATIONS These publications can help you install the air FOR MORE INFORMATION, CONTACT conditioner or heat pump. You can usually find these THESE PUBLISHERS: at your local library or purchase them directly from the publisher. Be sure to consult current edition of each ACCA Air Conditioning Contractors of America standard. 1712 New Hampshire Avenue Washington, DC 20009 National Electrical Code .......................ANSI/NFPA 70 Telephone: (202) 48

Summary of the content on the page No. 4

Geo-Trio™ GT Series Geothermal / Water Source Heat Pump Nomenclature “A” Coil Section GT A 3600 UD 1 A A 3600 (3 Ton) Revision Geo-Trio A = E Coated Coils 4860 (4 & 5 Ton) Level Option “A” = Coil Section Series Fossil Fuel “A” Coil Section GT ADP – 3642 – B Geo-Trio B = 17.50" Wide Furnace 3642 (3 Ton) C = 21.00" Wide Furnace 4860 (4 & 5 Ton) ADP = Advanced Distributor Products Blower Section GT B 1 – A Geo-Trio Revision A = 230 Volt 1-Phase Level B = Blower Section Option Compressor Sec

Summary of the content on the page No. 5

TABLE 1 — INDOOR BLOWER PERFORMANCE (RATED CFM)       Mild Climate   Full Load Minimum Air MODEL Rated MAX Continuous Operation Part Load Electric Heat Airflow Filter Face ESP ESP Airflow in Part Load Airflow Airflow Area Ft.2 Cooling GTC36S2 0.15 0.60 600 700 850 1200 1300 2.6 GTC48S2 0.20 0.60 750 875 1075 1500 1600 3.2 GTC60S2 0.20 0.60 900 1050 1300 1800 1800 3.6  Motor will automatically step through the various airflows with thermostatic control  ESP = External Stat

Summary of the content on the page No. 6

TABLE 4 WATER COIL PRESSURE DROP Model GTC36S2 GTC48S2 GTC60S2 GPM PSID Ft. Hd. PSID Ft. Hd. PSID Ft. Hd. 3 0.1 0.23 4 0.5 1.15 0.9 2.08 5 1.2 2.77 1.4 3.23 6 1.7 3.92 2.3 5.31 7 2.3 5.31 3.2 7.38 2 4.61 8 3.1 7.15 4.1 9.46 2.5 5.77 9 4.1 9.46 5.1 11.77 3.2 7.38 10 6.1 14.07 3.9 9.00 11 7.1 16.38 4.7 10.84 12 8.2 18.92 5.5 12.69 13 9.4 21.69 6.4 14.76 14 10.6 24.45 7.3 16.84 15 8.1 18.69 16 9 20.76 17 9.9 22.84 18 Manual 2100-537I Page 6 of 54

Summary of the content on the page No. 7

Manual 2100-537I Page 7 of 54 FIGURE 1A – GTA****UD1AA A-COIL SECTION DIMENSIONS GTA Coil Dimensions If Used Without Cabinet COIL +.125 16.13 HEIGHT -.000 30" COATED DRAIN PAN +.125 2.25 -.000 +.125 28.25 DEPTH -.000 +.125 20.50 WIDTH -.000 SECONDARY DRAIN HOLE PRIMARY DRAIN HOLE MIS-2876 A 22" 27 15/16" 19 15/16" 2 3/16" 1 1/2" CONDENSATE HORIZ. MAIN DRAIN K.O. OVERFLOW WIRES HORIZ. OVERFLOW K.O. 3 1/2" 1 13/16" SUCTION CONNECTION 21 5/8" 17 5/8" LIQUID CONNECTION 15 11/16" 13 5/8" MAIN DR

Summary of the content on the page No. 8

FIGURE 1B – GTADP****-* FOSSIL FUEL ADP COIL SECTION DIMENSIONS FIGURE 1B - GTADP****-* FOSSIL FUEL ADP COIL SECTION DIMENSIONS GTADP-3642-C DIMENSION GTADP-3642-B GTADP-4860-C "A" 17 5/8" 21 1/8" "B" 25 1/2" 27 1/2" "C" 7 1/4" 6 3/4" "D" 2 1/8" 2 1/2" "E" 3 7/8" 4 1/4" "F" 13 7/8" 16 7/8" "G" 15 5/8" 18 5/8" "A" 21 1/4" 3/4" 3/4" 3/4" TYP TYP TYP SUCTION "C" CONNECTION 5 1/4" "B" LIQUID "E" CONNECTION "D" OVERFLOW OVERFLOW MAIN DRAIN MAIN DRAIN 6 1/16" 1 5/8" "F" "G" MIS-311

Summary of the content on the page No. 9

FIGURE 1C – GTB1-A BLOWER SECTION DIMENSIONS 16 3/8" 30" 13 1/4" LOW VOLTAGE ENTRANCE HIGH VOLTAGE K.O. FOR 3 5/8" REMOTE APPLICATIONS ONLY 22" 1 1/4" 24 9/16" 18 13/16" 21" 15 5/8" OPTIONAL SIDE RETURN OPENING ON BOTH SIDES 15" 2 7/8" 3 5/16" 24" MIS-2819 1 1/2" Manual 2100-537I Page 9 of 54

Summary of the content on the page No. 10

Manual 2100-537I Page 10 of 54 FIGURE 1D – GTC**S2-D COMPRESSOR SECTION DIMENSIONS MODEL DIM. A DIM. B GTC36S2 21" 4 1/8" GTC48S2 20" 3 7/8" GTC60S2 18 1/2" 3 3/4" 30" 22 1/16" B WATER OUT 1 15/16" 1 3/4" LOW VOLTAGE WIRE ENTRANCE SUCTION LINE 3" DESUPERHEATER WATER OUT HIGH VOLTAGE UNIT 23 1/16" POWER ENTRANCE A DESUPERHEATER 16 15/16" WATER IN 16 1/16" HIGH VOLTAGE OPTIONAL 12 1/4" LIQUID LINE FLOW CENTER WIRE ENTRANCE 9 5/8" 1 7/8" 8" 6 15/16" WATER IN 4 13/16" 2 1/2" MIS-2820 A

Summary of the content on the page No. 11

Manual 2100-537I Page 11 of 54 FIGURE 1E – ASSEMBLED UPFLOW / COUNTERFLOW APPLICATION DIMENSIONS SECURE SECTIONS TOGETHER TOP DUCT OUTLET FLANGE USING BOLT PART #1012-015 AND WASHER PART #1012-109 MODEL DIM. A 19 13/16" GTC36S2 39 7/16" GTC48S2 40 15/16" GTC60S2 41 15/16" 27 15/16" TOP MAIN DRAIN OUTLET REFRIGERANT OVERFLOW DRAIN OUTLET 3/4" 31 1/4" CONNECTIONS WATER OUT DESUPERHEATER OUTLET 21 5/8" LOW VOLTAGE DESUPERHEATER INLET 61 5/8" WATER IN 59 11/16" LOW VOLTAGE 65 5/8" HIGH 23" 55"

Summary of the content on the page No. 12

Manual 2100-537I Page 12 of 54 FIGURE 1F – HORIZONTAL APPLICATION DIMENSIONS Evaporator and Blower in Horizontal Position Blower (Remote Compressor Section) Section Top View Horiz. Support Bracket NOTE: Requires horizontal 30" GTHZ1 High Voltage drain pan kit 1 Horizontal Entrance 31 " 4 Drain Pan Low Voltage Evaporator 1 Model GTHZ-1 1 " (Req'd) Entrance 4 Section 1 3 " 2 3 1 " Low Voltage 4 3 Entrance 18 " 8" 4 3 43 " 8 7 3 27 " 8 " 24" 21" 4 Main Drain Outlet Overflow Drain 7 19 " Outlet

Summary of the content on the page No. 13

Blower Air Blower Air Manual 2100-537I Page 13 of 54 FIGURE 2A – UPFLOW & COUNTERFLOW DUCTING CONFIGURATIONS Supply Return Upflow Counterflow Position Position Secondary Secondary Drain Drain Main Drain Main Drain 7/8" Line Set Evap. Coil 7/8" Line Set Evap. Coil Cond. Coil Cond. Coil Water Out Water Out 3/8" Line Set 3/8" Line Set Desuper. Desuper. Water Out Water Out Control Panel Control Panel Desuper. Desuper. Water In Water In Cond. Coil Cond. Coil Water In Water In Return Return

Summary of the content on the page No. 14

Blower Air Blower Air < > Manual 2100-537I Page 14 of 54 FIGURE 2B – HORIZONTAL & COUNTERFLOW DUCTING CONFIGURATIONS Supply Return Counterflow Upflow Return Horizontal, Left Discharge Position Position Supply Return Evap. Coil Refrigerant Connections Blower Air Secondary Evap. Coil Secondary Evap. Coil Drain Drain Main Drain Main Drain Blower in Refrigerant Main Drain Shipped Position Connections Return Return Secondary Drain NOTE: Requires horizontal drain pan kit Model GTHZ-1 Blower in S

Summary of the content on the page No. 15

BLOWER LINE POWER CONNECTION BLOWER CONVERSION FROM UPFLOW TO COUNTERFLOW OR HORIZONTAL Power connections for the GTB1-A can be made two RIGHT DISCHARGE different ways. Following the directions on Figure 3 for counterflow and The first is in “stacked” configurations, the blower can horizontal right discharge, the indoor blower must be be plugged into an electrical connection from the bottom removed and turned over in its mounting configuration. of the compressor (GTC**S2 Model Unit). Thi

Summary of the content on the page No. 16

Manual 2100-537I Page 16 of 54 FIGURE 3 – BLOWER CONFIGURATIONS REMOVE (2) SCREWS SECURING BLOWER AND SLIDE BLOWER 2 OUT OF CABINET REMOVE (2) SCREWS FROM FRONT FILL PLATE AND SLIDE 1 BACK FILL PLATE OUT OF CABINET REMOVE BOTH FRONT PANELS 3 4 DISCARD BACK FILL PLATE 5 ROTATE BLOWER AND SLIDE 6 INTO BOTTOM OFFSETS REINSTALL FRONT FILL PLATE REINSTALL (2) SCREWS REINSTALL BOTH SECURING BLOWER TO MIS-2842 A FRONT FILL PLATE FRONT PANELS

Summary of the content on the page No. 17

Manual 2100-537I Page 17 of 54 FIGURE 4 – BLOWER POWER CONNECTIONS MOUNT FIELD SUPPLIED SINGLE GANG ELECTRICAL BOX ALIGNED OVER HIGH VOLTAGE K.O. PLUG BLOWER POWER CONNECTOR INTO POWER PLUG PROTRUDING THROUGH REMOVE SUPPLIED CONDENSER BASE FOR BOTH WIRE HARNESS AND UPFLOW AND COUNTERFLOW STRAIN RELIEF BUSHING STACKED CONFIGURATIONS FROM BLOWER POWER PLUG. ROUTE WIRE HARNESS THROUGH STRAIN RELIEF AND INTO ELECTRICAL BOX TO MAKE FIELD POWER CONNECTION MIS-2843

Summary of the content on the page No. 18

APPLICATION AND LOCATION GENERAL DUAL FUEL HEATING / COOLING Dual fuel is the combination of a fossil fuel furnace, normally The GT Series Geothermal Heat Pumps feature three sections gas or oil, with a heat pump. In milder weather the heat pump (GTA - Air Coil Section, GTB - Blower Section and GTC - uses the available outdoor warmth and will transport that heat Compressor Section) which cover upflow (bottom, right/left- into your house cheaper than burning gas or oil. When it gets side

Summary of the content on the page No. 19

CAUTION NEVER OPERATE MORE THAN 10KW STRIP HEAT WITH GEOTHERMAL HEAT PUMP OPERATIONAL. USE ADDITIONAL KW STRIP HEAT BEYOND 10KW ONLY IN EMERGENCY HEAT MODE. TABLE 5 ELECTRICAL HEAT SPECIFICATIONS Maximum Field Minimum 240 Volts 208 Volts For Use Heater Heater HACR Wire Circuit With Package Package Circuit Size Ampacity KW Amps BTUH KW Amps BTUH Breaker + 8604-080 240/208-60-1 5.0 20.8 17,065 3.75 18.0 12,799 26.0 30 #10 All 8604-081 240/208-60-1 9.8 40.8 33,447 7.35 35.3 25,

Summary of the content on the page No. 20

TABLE 6 FILTER SIZING CHART Airflow CFM Airflow CFM Airflow CFM Filter Nominal Size Surface Area FT2 Filter Type Capability @ 300 Capability @ 500 Capability @ 625 FPM Velocity FPM Velocity FPM Velocity 10" X 20" X 1" 1.39 415 12" X 20" X 1" 1.67 500 14" X 20" X 1" 1.94 580 14" X 25" X 1" 2.43 730 1" Fiberglass 16" X 20" X 1" 2.22 670 Not Recommended Not Recommended Disposable 16" X 25" X 1" 2.78 840 20" X 20" X 1" 2.78 840 20" X 25" X 1" 3.47 1050 24" X 24" X 1" 4.00 1200 10" X 20" X 2"


Alternative user manuals
# User manual Category Download
1 BMC GTADP-3642-B User manual Heat Pump 0
2 BMC GTC48S2-ADCX User manual Heat Pump 0
3 BMC GTC36S2-ADCX User manual Heat Pump 0
4 BMC GTADP-3642-C User manual Heat Pump 0
5 BMC GTC36S2-ADNX User manual Heat Pump 0
6 BMC GTC48S2-ADNX User manual Heat Pump 0
7 BMC GTB1-A User manual Heat Pump 0
8 BMC GTC60S2-ADNX User manual Heat Pump 0
9 BMC GTA3600UD1AA User manual Heat Pump 0
10 BMC GTA4860UD1AA User manual Heat Pump 0
11 BMC GTC60S2-ADCX User manual Heat Pump 0
12 Edelbrock 15005 User manual Heat Pump 0
13 A.O. Smith AH User manual Heat Pump 2
14 ACS 882.00217.00 User manual Heat Pump 1
15 A.O. Smith AHD 290 User manual Heat Pump 3
16 AC International SELF-PRIMING CENTRIFUGAL PUMPS User manual Heat Pump 5