Liebert EMERSON 60 HZ user manual

User manual for the device Liebert EMERSON 60 HZ

Device: Liebert EMERSON 60 HZ
Category: Fan
Manufacturer: Liebert
Size: 2.8 MB
Added : 9/19/2014
Number of pages: 20
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Liebert EMERSON 60 HZ. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Liebert EMERSON 60 HZ.

For your convenience

If looking through the Liebert EMERSON 60 HZ user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Liebert EMERSON 60 HZ on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Liebert EMERSON 60 HZ to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Liebert EMERSON 60 HZ User manual - Online PDF
Advertisement
« Page 1 of 20 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Liebert EMERSON 60 HZ but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Liebert EMERSON 60 HZ. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

HEAT REMOVAL/ENVIRONMENTAL CONTROL
Drycoolers - 60 Hz
GENERAL DATA

Summary of the content on the page No. 2

Summary of the content on the page No. 3

TABLE OF CONTENTS LIEBERT DRYCOOLERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 FEATURES AND BENEFITS OF LIEBERT DRYCOOLERS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 SELECTION PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 PERFORMANCE DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 4

Figures Figure 1 Drycooler model numbers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Figure 2 Capacity correction factor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Figure 3 Pressure drop correction factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Figure 4 Dimensional data—1-4 fan models

Summary of the content on the page No. 5

LIEBERT DRYCOOLERS Liebert drycoolers are designed to be used in conjunction with water cooled refrigeration and air conditioning machines as well as a variety of commercial and industrial applications requiring the rejection of heat from machinery or processes via a cooling fluid. During periods of low ambient temperatures, drycoolers may assist or replace the capacity requirements of mechanical chillers for a “free cooling” effect. Liebert offers a full range of control options as well as e

Summary of the content on the page No. 6

FEATURES AND BENEFITS OF LIEBERT DRYCOOLERS Heat Rejection Module The low-profile direct-drive propeller-fan type drycoolers utilize optimum circuitry to balance the heat rejec- tion of the corresponding load. Constructed of aluminum with a copper-tube aluminum coil, the unit is quiet and corrosion resistant. Low Noise Level All Liebert drycoolers are designed to operate at a minimal noise level. This is accomplished as the result of the Liebert fan blade design combined with a cabinet structu

Summary of the content on the page No. 7

SELECTION PROCEDURE Table 4 shows the performance specifications for The MBH found should be equal to or greater than Liebert drycoolers using a 40% by volume ethylene the “required MBH /ITD.” glycol solution at an average fluid temperature of If the MBH is less than required, repeat from Step 2 115°F with flow rates from 1.5 to 3 GPM/circuit and with a larger model. You may wish to repeat from 3 at standard air (.075 lbs/ft ). Figure 2 and Figure 3 Step 2 with a smaller model for the most

Summary of the content on the page No. 8

PERFORMANCE DATA Table 4 Drycooler performance data MBH/°F Initial Temperature Difference 1.5 GPM/CIR 2.0 GPM/CIR 2.5 GPM/CIR 3.0 GPM/CIR Model GPM No. of Number Range Circuits MBH/ITD PD ft. water MBH/ITD PD ft. water MBH/ITD PD ft. water MBH/ITD PD ft. water Standard Models 033 6-12 4* 1.3 4.2 1.5 6.2 1.6 9.2 1.7 12.8 069 6-12 4 1.8 7.3 2.1 11.4 2.3 17.0 2.4 23.6 12-24 8* 2.3 3.9 2.5 6.0 2.7 8.9 2.8 12.4 092 9-18 6 2.7 7.0 3.0 11.7 3.3 16.7 3.5 23.0 18-36 12' 3.2 3.7 3.5 6.2 3.7 8.7 3.8 12.1 2

Summary of the content on the page No. 9

Table 4 Drycooler performance data (continued) MBH/°F Initial Temperature Difference 1.5 GPM/CIR 2.0 GPM/CIR 2.5 GPM/CIR 3.0 GPM/CIR Model GPM No. of Number Range Circuits MBH/ITD PD ft. water MBH/ITD PD ft. water MBH/ITD PD ft. water MBH/ITD PD ft. water Quiet-Line Models 040 6-12 4 1.4 7.4 1.5 11.4 1.6 17.0 1.7 23.5 12-24 8* 1.6 3.9 1.7 5.9 1.8 8.9 1.8 12.3 057 18-36 12* 2.1 3.6 2.2 6.1 2.3 8.6 2.3 11.9 24-48 16 2.2 3.0 2.3 4.6 2.3 6.2 2.4 8.6 060 12-24 8 2.2 7.1 2.3 11.3 2.4 16.6 2.5 23.0 24-

Summary of the content on the page No. 10

DIMENSIONAL DATA Figure 4 Dimensional data—1-4 fan models L 43-9/16" 70" (962mm) Eyebolts for lifting (1778mm) condenser provided on Height to top 4, 6 & 8 fan models only of fan guard 37-7/8" 43-1/8" (962mm) (1095mm) 18" (457mm) C 43-3/16" Center leg provided on 4 & 8 fan models only (1097mm) Figure 5 Dimensional data—6 & 8 fan models L 87-1/8" 36" (914.4mm) 70" (2213mm) clearance (1778mm) recommended on Height to top all sides for of fan guard proper operation 43-1/8" and component (109

Summary of the content on the page No. 11

Table 5 Drycooler physical data Drycooler #Fans Conn FNPT Model Circuits A B C L & Motors** In/Out Standard Models -033 any 42 - 44 51.5 1 3/4 -069 any 42 - 44 51.5 1 1-1/4 -092 any 42 - 44 51.5 1 1-1/2 -109 any 42 - 44 51.5 1 2 -112 any 42 - 44 51.5 1 2 -139 any 82 - 84 91.5 2 2 -174 any 82 - 84 91.5 2 2 -197 any 82 - 84 91.5 2 2 -225 any 82 - 84 91.5 2 2 -260 any 122 - 124 131.5 3 2 -310 any 122 - 124 131.5 3 2 -350 any 122 - 124 131.5 3 2 -352 any 82 80 164 171.5 4 2 -419 any 82 80 164 171.5

Summary of the content on the page No. 12

ELECTRICAL DATA Table 6 Drycooler electrical data # of Fans 12 3468 Model # 33,69,92,109,112 139,174,197,225 260,310,350 352,419,466,491 620,650,700 790,880,940 Pump Hp ph FLA WSA OPD ph FLA WSA OPD ph FLA WSA OPD ph FLA WSA OPD ph FLA WSA OPD ph FLA WSA OPD 208/230/60 0.75 1 11.6 13.5 20.0 - - - - - - - - - - - - - - - - - - - - 0.75 3 7.0 7.9 15.0 3 10.5 11.4 15.0 3 14.0 14.9 15.0 3 17.5 18.4 20.0 3 24.5 25.4 25.0 3 31.5 32.4 35.0 1.5 3 10.1 11.8 15.0 3 13.6 15.3 20.0 3 17.1 18.8 25.0 3 20.6 2

Summary of the content on the page No. 13

Table 7 Drycooler electrical data—Quietline models # of Fans 12 3468 Model # 40,57,60 80,111,121 158,173,178 205,248 347,356 453,498 Pump Hp ph FLA WSA OPD ph FLA WSA OPD ph FLA WSA OPD ph FLA WSA OPD ph FLA WSA OPD ph FLA WSA OPD 208/230/60 0.75 3 5.3 6.2 15.0 3 7.1 8.0 15.0 3 8.9 9.8 15.0 3 10.7 11.6 15.0 3 14.3 15.2 15.0 3 17.9 18.8 20.0 1.5 3 8.4 10.1 15.0 3 10.2 11.9 15.0 3 12.0 13.7 20.0 3 13.8 15.5 20.0 3 17.4 19.1 25.0 3 21.0 22.7 25.0 2.0 3 9.3 11.2 15.0 3 11.1 13.0 20.0 3 12.9 14.8 20.

Summary of the content on the page No. 14

GUIDE SPECIFICATIONS Standard Features for Direct Casing Quiet-Line Motors Drive Propeller Fan The drycooler casing shall be con- Fan motors shall be 12-pole, Drycoolers structed of bright aluminum 570 rpm, equipped with rain sheet. Casing shall be divided into shields and permanently sealed Furnish and install Liebert Model individual fan sections by full ball bearings. Motors shall ________ Air-Cooled Drycoolers, width baffles. Structural support include built-in overload protec- arrang

Summary of the content on the page No. 15

COMPONENT ASSEMBLY/INSTALLATION Leg Assembly The legs are shipped loose and are to be field mounted as shown with the hardware provided. Secure each leg to drycooler frame at all four points shown using hardware provided Electrical service Inlet Outlet supply by others Models 069-491 Models 620 through 940 have 2 sets of connections on end of unit Figure 7 General arrangement diagram Optional dual pump Fill* system shown Typical rigging Expansion Drycooler coil tank field Drycooler Glyc

Summary of the content on the page No. 16

APPLICATION/INSTALLATION GUIDELINES indoor unit and the drycooler is a Location Guidelines Piping Considerations two wire control interlock which is To ensure an adequate air supply, CAUTION: When using water field-connected when provided. locate drycoolers in a clean air under pressure to test the system area, away from loose dirt and for- for leaks, immediately charge the Glycol/Inhibitor Solution eign matter that may clog the coil. tested system with glycol. Com- The percentage of glycol

Summary of the content on the page No. 17

PUMP PACKAGES & EXPANSION TANK - OPTIONS Figure 8 Pump package Figure 10 Expansion tank See 30-1/4" Note 1 (768.4mm) Pump discharge connections 19" (483mm) Pump suction connections Provided on dual pump package only Expansion Tank- (P/N 1C16717P1) This tank, included in a standard pump package, has an internal volume of 8.8 gal. (33 l) and a maximum pressure of 100 psi (690 kPa). Figure 9 Pump mounting This tank is sized for a typical “open” system with a fluid volume of less than 75 gal.

Summary of the content on the page No. 18

SUPPLEMENTARY APPLICATION DATA Table 9 Room dew point temperatures Table 11 Volume in standard tube Dry bulb Wet bulb Rel. hum. Dew point* Type “L” copper tube °F (°C) °F (°C) % °F (°C) Diameter (in.) Volume 70 57.2 45 41.1 Outside Inside Gal/ft (L/m) 70 58.5 50 50.5 .50 0.430 0.0075 (0.09) 72 58.9 45 50.0 .625 0.545 0.0121 (0.15) 72 60.0 50 52.4 75 61.2 45 52.4 .75 0.666 0.0181 (0.22) 75 62.5 50 55.0 .875 0.785 0.0251 (0.31) * Minimum glycol temperature before condensation will occur 1.125 1.02

Summary of the content on the page No. 19

Summary of the content on the page No. 20

HEAT REMOVAL/ENVIRONMENTAL CONTROL Drycoolers - 60 Hz GENERAL DATA Technical Support The Company Behind the Products United States With over a million installations around the globe, 1050 Dearborn Drive Liebert is the world leader in computer protection P.O. Box 29186 systems. Since its founding in 1965, Liebert has Columbus, OH 43229 developed a complete range of support and protection systems for sensitive electronics: Single-Phase UPS • Environmental systems—close-control air 800-543-2378 co


Alternative user manuals
# User manual Category Download
1 A.O. Smith 160M User manual Fan 5
2 A.O. Smith 200M User manual Fan 2
3 A.O. Smith HW-120M User manual Fan 0
4 Acnodes EPSON PERFECTION 1200S User manual Fan 1
5 Aero Mist 67014 User manual Fan 0
6 Air King 1VN45 User manual Fan 0
7 Air King 4TM61C User manual Fan 0
8 A.O. Smith 225M User manual Fan 1
9 Able Planet 620DuN User manual Fan 7
10 Air King 4YN46C User manual Fan 0
11 Air King 4C796E User manual Fan 0
12 Air King 3C614D User manual Fan 0
13 Air King 4TM65A/9530A User manual Fan 1
14 Air King 9020C User manual Fan 5
15 Air King 4C631P/9016P User manual Fan 0