Generac Power Systems OG 2697 user manual

User manual for the device Generac Power Systems OG 2697

Device: Generac Power Systems OG 2697
Category: Fan
Manufacturer: Generac Power Systems
Size: 1.26 MB
Added : 5/13/2014
Number of pages: 20
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Generac Power Systems OG 2697. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Generac Power Systems OG 2697.

For your convenience

If looking through the Generac Power Systems OG 2697 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Generac Power Systems OG 2697 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Generac Power Systems OG 2697 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Generac Power Systems OG 2697 User manual - Online PDF
Advertisement
« Page 1 of 20 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Generac Power Systems OG 2697 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Generac Power Systems OG 2697. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

GenerATor
INSTALLATION
GUIDELINES
Air-Cooled Generators
Distributed Load Center Transfer Switch
OG 2697

Summary of the content on the page No. 2

This booklet and the accompanying video are designed to familiarize you with the installation process for your air-cooled generator. Neither this booklet nor the accompanying video replace or supersede any information contained in any of the written documents shipped with your equipment. This booklet should only be used in conjunction with the Owner’s Manual, Installation Guide and other technical documents shipped with your equipment. Future product updates and/or modifications will be ref

Summary of the content on the page No. 3

This exhaust system must be installed to isolate the electrical system from the utility properly, in strict compliance with applicable distribution system when the generator is codes and standards. operating. Failure to isolate the electrical system by these means will result in damage Keep hands, feet, clothing, etc., away from to the generator and may also result in injury drive belts, fans and other moving or hot or death to utility workers due to backfeed of parts. Never remove an

Summary of the content on the page No. 4

NFPA 0, LIFE SAFETY CODE Grounding the Generator NFPA 0, ST  ANDARD FOR A grounding lug is provided on the generator EMERGENCY AND STANDBY mounting base for the purpose of grounding the POWER SYSTEMS frame and the external electrically conductive NFPA 0, STANDARD TYPES OF parts of this equipment to an approved earth BUILDING CONSTRUCTION ground and/or grounding rods where required by the National Electrical Code. Grounding NOTE: procedures must meet local regulation

Summary of the content on the page No. 5

Do not open or mutilate the battery. Released Servicing of batteries is to be performed or electrolyte can be toxic and harmful to the supervised by personnel knowledgeable of skin and eyes. batteries and the required precautions. Keep unauthorized personnel away from batteries. The battery represents a risk of high short-circuit current. When working on the For recommended batteries, see the battery, always remove watches, rings or Installation Guide. All batteries must be at other meta

Summary of the content on the page No. 6

BEFOrE YOu BEGIN Carefully read and follow all of the procedures and safety precautions detailed in the installation guide. If you do not completely understand any portion of the installation manual, technical manual or other factory-supplied documents, contact an authorized dealer for assistance. Fully comply with all relevant NEC, NFPA and OSHA standards as well as all federal, state and local building and electric codes. As with any generator, this unit must be installed in accordance wit

Summary of the content on the page No. 7

Make sure the lifting equipment you’ll be using has sufficient capacity to safely handle the weight of the generator. Use nylon lifting straps and connect them to the lifting eyes on each corner of the base frame to avoid damaging the enclosure. Set the generator onto the pad so that the gravel bed extends several inches beyond the generator on all sides. Make sure the generator is level within ½ inch. Some locations require the use of a poured concrete mounting pad. If you’re using a

Summary of the content on the page No. 8

Check the engine oil, and if necessary, add enough of the recommended oil to bring the level up to the FULL mark on the dipstick. Be careful not to overfill the crankcase. Converting To LP Vapor The generator was configured for natural gas operation at the factory. Switching over to LP vapor is a simple procedure. On models with the V-Twin engine, simply flip the fuel selection switch from natural gas to LP. On models with a single-cylinder engine, start by making sure the battery is

Summary of the content on the page No. 9

Replace the fuel hose and clamp. Then reconnect the wires to the solenoid. Finally, insert the plastic plug that came with the generator into the hole on the bottom of the air cleaner base. Installing & Connecting Gas Lines Both natural gas and LP vapor are highly volatile substances, so strict adherence to all safety procedures, codes, standards and regulations is essential. Gas line connections should be made by a certified plumber familiar with local codes. Always use

Summary of the content on the page No. 10

When connecting the gas line to the generator, use a short section of UL Listed or AGA- approved flexible fuel line in accordance with local regulations. The purpose of the flexible fuel line is to ensure that vibration from the generator does not cause a gas leak at one of the connection points, so it’s important that the line be installed with as few bends as possible. Never bend the flexible fuel line to avoid using an elbow. Bending the flexible line decreases its ability to abso

Summary of the content on the page No. 11

External Electrical Connections Drill a ¾ inch hole and feed the conduit through the hole. Remove the knockout in the back of the connection box, feed the wires through the back of the box and secure the conduit with the lock nut. Seal the hole with silicone caulk. Don’t forget to caulk the hole inside the house as well. Mount the connection box so that it completely covers the hole in the wall. Connect all wires to the lugs in the connection box (black to black, red to red an

Summary of the content on the page No. 12

Installing The Automatic Transfer Switch Before beginning any installation, make sure power is shut OFF to the main distribution panel and carefully read the Installation Guide that came with your transfer switch. The distributed load center switch must be mounted close enough to the main distribution panel to accommodate the two-foot, pre-wired conduit. Make sure no water or corrosive substances can drip onto the transfer switch enclosure. Always inspect the switch for shipping damage.

Summary of the content on the page No. 13

When three-conductor wiring is used, two 0 volt circuits will often share the same neu tral wire. To avoid overloading the neutral, you should either move BOTH of the circuits that share the neutral or don’t move either of them. When moving two circuits with a shared neutral, they should be connected to adjacent positions (one above the other) in the transfer switch. That will assure that the two hot wires are on separate phases and will maintain their relationship to neutral.

Summary of the content on the page No. 14

Install a -pole breaker in the distribution panel to protect the transfer switch. The required Amp rating of the breaker depends on which transfer switch you’re using, so refer to the Installation Guide before purchasing the breaker. Install the breaker in two adjacent empty slots (one above the other) in the main panel. When all emergency circuits have been moved to the transfer switch, close the main breaker to restore utility power and make sure utility voltage at the transfer swit

Summary of the content on the page No. 15

Locate the transfer handle and insert the metal end into the slot in the main contactor assembly. Pull the handle DOWN to move the main contacts to the standby power (generator) position. NEVEr OPErATE THE TrANSFEr SWITCH MANuALLY WHEN LOADS ArE CONNECTED. Put the generator’s mode switch in MANUAL to start the engine. Allow the engine to warm up, then switch the generator’s main breaker to the ON position. The generator is now supplying electricity to the transfer switch but

Summary of the content on the page No. 16

Use the transfer handle to move the main contacts in the transfer switch to the UP (utility) position. Switch the -pole breaker ON in the distribution panel. Now switch the generator’s main breaker ON and put the mode switch in AUTO. Shut OFF utility power and make sure the generator starts automatically. If everything worked properly, switch the main breaker to ON and make sure that power is automatically transferred back to the utility. 5

Summary of the content on the page No. 17

After the engine has completed its cool down cycle and shut down, shut OFF utility power again. When the generator is supplying power to the transfer switch, move the breakers in the switch to the ON position one at a time until the generator has accepted the entire emergency load. With the generator carrying the entire emergency load, re-check gas pressure to verify that it is at the same level it was before you started the generator. Switch the main breaker ON to restore ut

Summary of the content on the page No. 18

Shut OFF utility power again. The generator should start and the entire emergency load should transfer to the generator. Close the main breaker to restore utility power and allow the engine to cool down and shut itself OFF. Setting The Automatic Exercise Function With the mode switch in AUTO, press the EXERCISER switch. Hold it down for at least 0 seconds and release.  The generator should start within a few seconds. The unit will run for about  minutes before shutting itself

Summary of the content on the page No. 19

Notes 8 

Summary of the content on the page No. 20

Every installation has its own unique set of circumstances and requirements. This booklet provides guidelines for basic installations only and is not intended to cover all applications. If you have any questions or concerns after carefully reading all documentation received with the equipment, contact your local dealer for assistance. Part# 0G697 Printed in USA 08/06 ©006 Generac Power Systems, Inc. All rights reserved.


Alternative user manuals
# User manual Category Download
1 A.O. Smith 160M User manual Fan 5
2 A.O. Smith 200M User manual Fan 2
3 A.O. Smith HW-120M User manual Fan 0
4 Acnodes EPSON PERFECTION 1200S User manual Fan 1
5 Aero Mist 67014 User manual Fan 0
6 Air King 1VN45 User manual Fan 0
7 Air King 4TM61C User manual Fan 0
8 A.O. Smith 225M User manual Fan 1
9 Able Planet 620DuN User manual Fan 7
10 Air King 4YN46C User manual Fan 0
11 Air King 4C796E User manual Fan 0
12 Air King 3C614D User manual Fan 0
13 Air King 4TM65A/9530A User manual Fan 1
14 Air King 9020C User manual Fan 5
15 Air King 4C631P/9016P User manual Fan 0