England's Stove Works 60-TRULP user manual

User manual for the device England's Stove Works 60-TRULP

Device: England's Stove Works 60-TRULP
Category: Fan
Manufacturer: England's Stove Works
Size: 0.2 MB
Added : 5/4/2013
Number of pages: 13
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for England's Stove Works 60-TRULP. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with England's Stove Works 60-TRULP.

For your convenience

If looking through the England's Stove Works 60-TRULP user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual England's Stove Works 60-TRULP on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual England's Stove Works 60-TRULP to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
England's Stove Works 60-TRULP User manual - Online PDF
Advertisement
« Page 1 of 13 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual England's Stove Works 60-TRULP but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to England's Stove Works 60-TRULP. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

UNVENTED ROOM HEATER
MODELS: 26-GULP 26-GUNG
60-SHULP 60-SHUNG
60-TRULP 60-TRUNG
26-GUHLP 26-GUHNG
60-SHUHLP 60-SHUHNG
60-TRUHLP 60-TRUHNG

NOTE: IF YOU HAVE A PROBLEM WITH THIS UNIT DO NOT RETURN IT TO THE
DEALER. CONTACT ENGLAND’S CUSTOMER SERVICE: 1-800-245-6489.

INSTALLATION AND OPERATING INSTRUCTIONS

England’s Stove Works highly recommends the use of smoke detectors and

Carbon Monoxide detectors with any hearth product, including this

Summary of the content on the page No. 2

A letter from our Technical Support department: Thank you for purchasing this fine product from England’s Stove Works! England's Stove Works was started, and is still owned by, a family that believes strongly in a "Do It Yourself" spirit – that’s one reason you found this product at your favorite “Do It Yourself” store. We intentionally design and build our stoves so that any homeowner can maintain his or her unit with basic tools, and we're always more than happy to show you how t

Summary of the content on the page No. 3

INSTALLATION INSTRUCTIONS 1. Minimum inlet gas supply pressure must be 5.5” w.c. for natural gas and 11” w.c. for propane (LP) gas for the purpose of adjustment. Maximum gas supply pressure must not exceed 10.5” w.c. with natural gas, or 14” w.c. with propane (LP) gas. Use the correct gas type for your appliance — check the tag for gas type and do not convert from one to the other. If you are using propane the tank must be located outdoors. Warning: Connecting directly to an unregulated

Summary of the content on the page No. 4

GAS RATINGS TYPE OF GAS → NATURAL L.P./PROPANE MAX. INPUT 34,500 BTU/HR 30,000 BTU/HR MIN. INPUT 20,000 BTU/HR 20,000 BTU/HR MANIFOLD PRESSURE 3.5” W.C. 10” W.C. M/FOLD PRESSURE LOW 1.0/3.5” W.C. 4.5/10.0” W.C. MIN. INLET PRESSURE 5.0” W.C. 11.0” W.C. MIN. SUPPLY PRESSURE 5.5” W.C. 11” W.C. MAX. SUPPLY PRESSURE 10.5” W.C. 14” W.C. ORIFICE SIZE #34 #51 MINIMUM CLEARANCES TO COMBUSTIBLES T

Summary of the content on the page No. 5

This heater is equipped with a PILOT LIGHT (OXYGEN DEPLETION SENSOR) SAFETY SYSTEM designed to turn off the unit if there is not sufficient fresh air available. If the appliance keeps shutting off, have it serviced. DO NOT TAMPER WITH THE PILOT LIGHT (ODS) SAFETY SYSTEM! Keep the burner and control compartment clean. CARBON MONOXIDE POISONING MAY LEAD TO DEATH Early signs of carbon monoxide poisoning resemble the flu, with headache, dizziness and/or nausea; if you h

Summary of the content on the page No. 6

WARNING: IF THE AREA IN WHICH THE HEATER MAY BE OPERATED IS SMALLER THAN THAT DEFINED AS AN UNCONFINED SPACE, PROVIDE ADEQUATE COMBUSTION AND VENTILATION AIR BY ONE OF THE METHODS DESCRIBED IN THE NATIONAL FUEL GAS CODE, ANSI Z223.1 (SECTION 5.3). “The National Fuel Gas Code defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 BTU per hour (4.8 m3 per KW) of the aggregate input rating of all appliances installed in that space and an unconfined spac

Summary of the content on the page No. 7

FOR YOUR SAFETY - READ BEFORE OPERATING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. This unit has a piezo ignition pilot. When lighting the pilot, follow these instructions exactly. A. BEFORE LIGHTING, smell around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS 1. Do not try to

Summary of the content on the page No. 8

MAIN BURNER IGNITION 1) Upon lighting, release knob and turn 3) Set thermostat to desired setting. 4) To turn off the gas to the main burner further counterclockwise ← to “ON” position (both pilot and gas flow). only, turn gas control clockwise → to 2) Turn on all electric power to appliance. pilot. TO TURN GAS OFF TO APPLIANCE 1) Set thermostat to the lowest setting. 5) Press down slightly and continue turning 2) Turn off all electric power to the clockwise → from pilot position to “OFF

Summary of the content on the page No. 9

PARTS LIST Model 26-GUNG/26-GULP and 26-GUHNG/26-GUHLP Model 60-SHUNG/60-SHULP and 60-SHUHNG/60-SHUHLP Model 60-TRUNG/60-TRULP and 60-TRUHNG/60-TRUHLP Exploded View No. Part No.* Part Name* 1 GUV-3211 Screen 2 GUV-3033 Valve Door Cover 3 GUV-3053 Burner Tube Supply Line NOTE: The following Valve/Burner assemblies are for GU, SHU and TRU models 4 GUV-30LP Gas Valve & Burner Assembly – LP GUV-30NG Gas Valve & Burner Assem

Summary of the content on the page No. 10

TROUBLE SHOOTING GUIDE ITEMS IN THIS GUIDE MARKED WITH AN ASTERISK (*) SHOULD ONLY BE PERFORMED BY A LICENSED GAS FITTER OR EQUIVALENT. WARNING CAUTION Turn off and let the unit cool before servicing. Never use a wire, needle, or similar Only a qualified service person should object to clean the ODS pilot. service or repair this unit. This can damage the pilot. PROBLEM POSSIBLE CAUSE SOLUTION When ignitor is presse

Summary of the content on the page No. 11

PROBLEM POSSIBLE CAUSE SOLUTION Pilot will not stay lit. Altitude is above 4000 ft.; ODS sensor requirement for air not satisfied. → Altitude is too high. Defective thermopile. → *Replace thermopile. Pilot orifice may be clogged. → *Clean out pilot orifice. Defective valve magnet. → *Replace valve. “ODS” pilot lights, but flame dies when control knob is released. Control knob not fully pressed in. → Press in knob completely. Co

Summary of the content on the page No. 12

WARRANTY INFORMATION ♦KEEP THIS WARRANTY ♦ Model #__________________________________ Serial #__________________________________ Date Purchased ___________________________ Manufacture Date _________________________ Purchased From (Dealer) ____________________ NOTE: Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard

Summary of the content on the page No. 13

WARRANTY REGISTRATION for England’s Stove Works Purchased by (Name) ______________________________________________ Address _________________________________________________________ City ________________________ State __________ Zip _________________ Telephone _______________________________________________________ Email Address ___________________________________________________ DEALER INFORMATION Purchased From (Dealer) ___________________________________________ Addre


Alternative user manuals
# User manual Category Download
1 England's Stove Works 60-SHUHLP User manual Fan 0
2 England's Stove Works 26-GUHNG User manual Fan 0
3 England's Stove Works 60-SHULP User manual Fan 0
4 England's Stove Works 60-TRUHNG User manual Fan 0
5 England's Stove Works 26-GUNG User manual Fan 0
6 England's Stove Works 60-SHUNG User manual Fan 0
7 England's Stove Works 60-TRUHLP User manual Fan 0
8 England's Stove Works 60-SHUHNG User manual Fan 0
9 England's Stove Works 26-GULP User manual Fan 0
10 England's Stove Works 60-TRUNG User manual Fan 0
11 England's Stove Works 26-GUHLP User manual Fan 0
12 A.O. Smith 160M User manual Fan 5
13 A.O. Smith 200M User manual Fan 2
14 A.O. Smith HW-120M User manual Fan 0
15 Acnodes EPSON PERFECTION 1200S User manual Fan 1
16 Aero Mist 67014 User manual Fan 0