Emerson CF901GES00 user manual

User manual for the device Emerson CF901GES00

Device: Emerson CF901GES00
Category: Fan
Manufacturer: Emerson
Size: 0.3 MB
Added : 4/25/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson CF901GES00. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson CF901GES00.

For your convenience

If looking through the Emerson CF901GES00 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson CF901GES00 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson CF901GES00 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson CF901GES00 User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson CF901GES00 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson CF901GES00. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

READ AND SAVE THESE INSTRUCTIONS

PRIMA
Ceiling Fan Owner's Manual
Model Numbers
CF901BS00 CF901ORB00
CF901CK00 CF901VNB00
CF901GES00
Net Weight: 20.3 Lbs.
Part No. F40BP74460000 Form No. BP7446
U.L. Model No.: CF901

Summary of the content on the page No. 2

! WARNING WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel. 3. Be careful of

Summary of the content on the page No. 3

This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan Installed Wire Length Wire Size A.W.G. Tools Needed for Assembly Up to 50 ft. 14 One Phillips head screwdriver One stepladder 50-100 ft. 12 One 1/4” blade screwdriver One wire stripper MATERIALS ! WARNING Wiring outlet box and box connectors must be of Before assembly your ceiling fan, refer to section type required by the local code. The minimum wire on proper method of wir

Summary of the content on the page No. 4

Electrical Requirements Your new ceiling fan will require a grounded electrical ! WARNING supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and Turning off wall switch is not sufficient. To avoid capable of withstanding a load of at least 50 pounds. possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and ! Local codes and the ceiling fan must be properly WARNING

Summary of the content on the page No. 5

How to Put Your Ceiling Fan Together (continued) 3. Make sure the grommet is properly installed in the coupling cover, then slide the coupling cover on the DOWNROD SETSCREW PIN downrod until it rests on the motor housing. Place HANGER the ceiling cover over the downrod. Be sure that BALL the ceiling cover and the coupling cover are both CEILING oriented correctly (Figure 3). COVER 4. Reinstall the hanger ball (Figure 3) on the downrod as follows. Route the three 80” motor leads through COUPLING

Summary of the content on the page No. 6

How to Put Your Ceiling Fan Together (continued) 11. Engage the connector of the switch housing assembly with the motor connector (Figure 7). The two connectors are keyed and color-coded and must be mated correctly (color-to-color) before they can be engaged. Make sure the connector latch closes properly. ! WARNING SWITCH HOUSING CONNECTOR To reduce the risk of personal injury, do not bend the MOTOR CONNECTOR blade flange when installing the blade flanges, balancing the blades or cleaning the fa

Summary of the content on the page No. 7

How to Hang Your Ceiling Fan CEILING ! WARNING The fan must be hung with at least 7' of clearance from floor to blades (Figure 9). AT LEAST 7' ! WARNING FLOOR The outlet box and joist must be securely mounted and Figure 9 capable of supporting at least 50 lbs. Use only a U.L. outlet box listed as “Acceptable for Fan Support of 22.7 kg. (50 lbs.) or less”. NOTE: CEILING COVER OUTLET OMITTED FOR CLARITY. ! WARNING BOX To reduce the risk of fire, electrical shock, or personal injury, mount fan to o

Summary of the content on the page No. 8

How to Wire Your Ceiling Fan If you feel that you do not have enough electrical BLUE wiring knowledge or experience, have your fan BLACK FAN WIRE YELLOW FAN FAN WIRE GROUND installed by a licensed electrician. WIRE WIRE LISTED ! WARNING WHITE SUPPLY WIRE (NEUTRAL) CONNECTOR (3) To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. NOTE: If you are not sure if the outlet box is grounded, contact a licensed electrician for advice, GREEN WIRE

Summary of the content on the page No. 9

4 3 2 1 0 4 3 2 1 0 Wall Control Installation The fan speed control is designed to operate only one ceiling fan, and not an accessory light kit. This wall control is rated for 1.2 amps at 120 volts. To avoid erratic speeds and possible damage to your ceiling fan, use this control only with the fan pull chain switch set to its high speed setting. NOTE: The “0” position is OFF. The four fan speeds are selected by sliding the bar to the other four speed positions (“1”, “2”, “3” and “4”). WALL 1. Be

Summary of the content on the page No. 10

Operation of Reverse Switch All fans are shipped from the factory with the reversing switch positioned to circulate air downward. If airflow is desired in the opposite direction, turn your SLIDE REVERSE SWITCH fan off and wait for the blades to stop turning, then RIGHT OR LEFT TO slide the reversing switch to the opposite position, and CHANGE BLADE DIRECTION turn fan on again. The fan blades will turn in the opposite direction and reverse the airflow (Figure 17). • Warm weather - (Counterclockw

Summary of the content on the page No. 11

Maintenance IMPORTANT CARE INSTRUCTIONS Abrasive cleaning agents are not required and should for your Ceiling Fan be avoided to prevent damage to finish. Periodic cleaning of your new ceiling fan is the only ! WARNING maintenance that is needed. When cleaning, use only a soft brush or lint free cloth Do not use water when cleaning your ceiling fan. It to avoid scratching the finish. could damage the motor or the blades and create the possibility of an electrical shock. Trouble Shooting WARNING:

Summary of the content on the page No. 12

Repair Parts 2 1 3 13 11 14 4 10 12 15 4 20 3 5 2 1 6 0 7 18 16 17 9 19 8 U.L. Model No.: CF901 12

Summary of the content on the page No. 13

Repair Parts Listing Key Model Numbers No. Description CF901BS00 CF901CK00 CF901GES00 CF901ORB00 CF901VNB00 * Hanger Ball Assembly, 761655-17 761655-23 761655-35 761655-32 761655-89 Consisting of: 1 Hanger Bracket — — — — — 2 Hanger Ball — — — — — 3 Downrod (4.5”) — — — — — * Parts Bag Containing: 764111-1 764111-1 764111 764111 764111 4 Wire Connector (3) — — — — — 5 Pin, Clevis (1) — — — — — 6 Clip, Hairpin (1) — — — — — 7 Screw, Washer Head, #10-24 x 7mm (16) — — — — — 8 Screw, Pan Head, 1/4-

Summary of the content on the page No. 14

Notes 14 U.L. Model No.: CF901

Summary of the content on the page No. 15

LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered. What The Period Of Coverage Is: As it applies to the motor, this warranty will last for the lifetime of your ceiling fan. All other components and accessories are covered by this warranty for one year from the date you purchased your

Summary of the content on the page No. 16

Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 Part No. F40BP74460000 Printed in China 12/11 Form No. BP7446 U.L. Model No.: CF901


Alternative user manuals
# User manual Category Download
1 Emerson BP7251 User manual Fan 0
2 Emerson CF2000PW02 User manual Fan 0
3 Emerson CF2000BC02 User manual Fan 0
4 Emerson CF2000WW02 User manual Fan 0
5 Emerson CF2000PB02 User manual Fan 0
6 Emerson CF2000AW02 User manual Fan 0
7 Emerson CF2000AB02 User manual Fan 0
8 Emerson CF24000SCK00 User manual Fan 0
9 Emerson CF2000WB02 User manual Fan 0
10 Emerson CF2400AB00 User manual Fan 0
11 Emerson CF2400BC00 User manual Fan 0
12 Emerson CF2400ORB00 User manual Fan 0
13 Emerson CF2400BZH00 User manual Fan 0
14 Emerson CF2400PW00 User manual Fan 0
15 Emerson CF2455BS00 User manual Fan 0
16 A.O. Smith 160M User manual Fan 5
17 A.O. Smith 200M User manual Fan 2
18 A.O. Smith HW-120M User manual Fan 0
19 Acnodes EPSON PERFECTION 1200S User manual Fan 1
20 Aero Mist 67014 User manual Fan 0