Carrier AIRSTREAM 42BVC user manual

User manual for the device Carrier AIRSTREAM 42BVC

Device: Carrier AIRSTREAM 42BVC
Category: Fan
Manufacturer: Carrier
Size: 2.13 MB
Added : 7/23/2014
Number of pages: 40
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Carrier AIRSTREAM 42BVC. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Carrier AIRSTREAM 42BVC.

For your convenience

If looking through the Carrier AIRSTREAM 42BVC user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Carrier AIRSTREAM 42BVC on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Carrier AIRSTREAM 42BVC to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Carrier AIRSTREAM 42BVC User manual - Online PDF
Advertisement
« Page 1 of 40 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Carrier AIRSTREAM 42BVC but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Carrier AIRSTREAM 42BVC. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

AIRSTREAM™
Product
42BHC,BVC
Data
System Fan Coils
600 to4000Cfm
Carrier’s versatile belted fan coil units
satisfy design requirements:
 A selection of 8 sizes covers
capacities from 600 to 4000 cfm
1
 Choice of motors, from / to 5 hp,
4
eliminates oversizing
 Wide range of coil options for 2-pipe
or 4-pipe systems
 Optional DX coils with expansion
valve and distributor
 Single and three-phase electric
heat (1.0 to 40 kW)
Features/Benefits
The 42BHC, BVC belt drive
42BHC UNIT
fan coil unit

Summary of the content on the page No. 2

provided on the top and bottom of each One-inch matte surface, fiberglass Fan wheels are designed to corner of the unit One-in. duct collars thermal/acoustical insulation lines the provide low operating costs on discharge and on return are fur- fan coil cabinets to prevent sweating The forward-curved, centrifugal, nished standard. These integral duct and to muffle sound transmission. double-inlet fans are statically and collars cut installation time and labor dynamically balanced at the f

Summary of the content on the page No. 3

Model number nomenclature 42BH C 08 L 42BH — Vertical Belt Drive Fan Coil Unit Coil — Rows 42BV — Vertical Belt Drive Fan Coil Unit B — 4, 2-Pipe 6, 2-Pipe L — H — 4/1, Same End Conn. C — Design K — 4/2, Same End Conn. N — 6/1, Same End Conn. Q — 6/2, Same End Conn. R — 8, 2-Pipe 1 — 4 With Electric Heat 2 — 6 With Electric Heat Size — Nominal Cfm 3 — 8 With Electric Heat 06 — 600 — 08 800 10 — 1000 12 — 1200 16 — 1600 20 — 2000 30 — 3000 40 — 4000 NOTE: Refer to current 42 Se

Summary of the content on the page No. 4

Options and accessories 42BHC, BVC OPTIONS AND ACCESSORIES electric heater data table for availability per unit) with single-stage or multiple-stage, single power source. ITEM OPTION* ACCESSORY† Voltages: Automatic Air Vents X Controls X  115 v, 208 v, 230 v and 277 v single-phase 60 Hz Electric Heat X  208 v, 230 v and 480 v three-phase 60 Hz Filters X Electric heat is available with the following staging options Heating/Cooling Coils X (3-phase staging is balanced). Insulation X Mixing Boxes

Summary of the content on the page No. 5

Thermostats — Three thermostats are available for field  programmable operating range, dead band, digital dis- installation: play, temperature set-back Honeywell T834C manual changeover, single-stage heat THERMOSTAT FUNCTIONS thermostat features: THERMOSTATS  off-cool-heat system switch SYSTEM FUNCTION CHANGEOVER Honeywell Honeywell Sunne  on-auto fan mode switch T834C T8500 T170 2Pipe HW-Heat Only ACO — XX  single-stage electric heat 2 Pipe CW-Cool Only ACO — XX  outside air signal MCO ——

Summary of the content on the page No. 6

Base unit dimensions 42BHC FAN COIL BASE UNIT (NO CONTROLS) DIMENSIONS (in.) UNIT Supply Duct Return Duct Mounting Holes 42BHC Fan Size Depth Width Height AB C D E F J K 3 11 1 1 9 7 1 1 7 3 1 06 9x 4 36 /16 28 /16 18 /2 7 /8 10 /16 13 /8 1 /8 24 /16 16 /16 27 /16 35 /4 3 11 1 9 9 7 1 1 7 3 1 08 9x 6 36 /16 28 /16 18 /2 8 /16 10 /16 13 /8 1 /8 24 /16 16 /16 27 /16 35 /4 3 1 1 1 11 7 1 1 3 3 13 10 10 x 4 37 /4 37 /16 20 /4 7 /2 11 /16 13 /8 1 /8 33 /16 18 /16 36 /16 36 /16 3 1 1 15 11 7 1 1 3 3 1

Summary of the content on the page No. 7

42BHC FAN COIL WITH MOTOR CONTROL OPTION DIMENSIONS (in.) UNIT Supply Duct Return Duct Mounting Holes 42BHC Fan Size Depth Width Height AB C D E F J K 3 11 1 1 9 7 1 1 7 3 1 06 9x 4 36 / 28 / 18 / 7 / 10 / 13 / 1 / 24 / 16 / 27 / 35 / 16 16 2 8 16 8 8 16 16 16 4 3 11 1 9 9 7 1 1 7 3 1 08 9x 6 36 / 28 / 18 / 8 / 10 / 13 / 1 / 24 / 16 / 27 / 35 / 16 16 2 16 16 8 8 16 16 16 4 3 1 1 1 11 7 1 1 3 3 13 10 10 x 4 37 / 37 / 20 / 7 / 11 / 13 / 1 / 33 / 18 / 36 / 36 / 4 16 4 2 16 8 8 16 16 16 16 3 1 1 15

Summary of the content on the page No. 8

Base unit dimensions (cont) 42BHC FAN COIL WITH ELECTRIC HEAT OPTION DIMENSIONS (in.) UNIT Supply Duct Return Duct Mounting Holes 42BHC Fan Size Depth Width Height AB C D E F J K 3 11 1 1 9 7 1 1 7 3 1 06 9x 4 36 / 28 / 18 / 7 / 10 / 13 / 1 / 24 / 16 / 27 / 35 / 16 16 2 8 16 8 8 16 16 16 4 3 11 1 9 9 7 1 1 7 3 1 08 9x 6 36 / 28 / 18 / 8 / 10 / 13 / 1 / 24 / 16 / 27 / 35 / 16 16 2 16 16 8 8 16 16 16 4 3 1 1 1 11 7 1 1 3 3 13 10 10 x 4 37 / 37 / 20 / 7 / 11 / 13 / 1 / 33 / 18 / 36 / 36 / 4 16 4 2

Summary of the content on the page No. 9

42BVC FAN COIL BASE UNIT (NO CONTROLS) DIMENSIONS (in.) UNIT Supply Duct Return Duct 42BVC Fan Size Depth Width Height AB C E F 1 1 1 9 3 1 7 06 9x 4 20 28 / 36 / 7 / 10 / 3 / 24 / 16 / 16 2 8 16 4 16 16 1 1 9 9 3 1 7 08 9x 6 20 28 / 36 / 8 / 10 / 3 / 24 / 16 / 16 2 16 16 4 16 16 1 3 1 11 1 1 3 10 10 x 4 22 37 / 39 / 7 / 11 / 5 / 33 / 18 / 16 8 2 16 2 16 16 1 3 15 11 1 1 3 12 10 x 7 22 37 / 39 / 9 / 11 / 5 / 33 / 18 / 16 8 16 16 2 16 16 1 3 5 11 7 1 3 16 11 x 10 22 47 / 39 / 13 / 12 / 16 / 43 /

Summary of the content on the page No. 10

Base unit dimensions (cont) 42BVC FAN COIL WITH MOTOR CONTROL OPTION DIMENSIONS (in.) UNIT Supply Duct Return Duct 42BVC Fan Size Depth Width Height AB C E F 1 1 1 9 3 1 7 06 9x 4 20 28 / 36 / 7 / 10 / 3 / 24 / 16 / 16 2 8 16 4 16 16 1 1 9 9 3 1 7 08 9x 6 20 28 / 36 / 8 / 10 / 3 / 24 / 16 / 16 2 16 16 4 16 16 1 3 1 11 1 1 3 10 10 x 4 22 37 / 39 / 7 / 11 / 5 / 33 / 18 / 16 8 2 16 2 16 16 1 3 15 11 1 1 3 12 10 x 7 22 37 / 39 / 9 / 11 / 5 / 33 / 18 / 16 8 16 16 2 16 16 1 3 5 11 7 1 3 16 11 x 10 22

Summary of the content on the page No. 11

42BVC FAN COIL WITH ELECTRIC HEAT OPTION DIMENSIONS (in.) UNIT Supply Duct Return Duct 42BVC Fan Size Depth Width Height AB C E F 1 1 1 9 3 1 7 06 9x 4 20 28 / 36 / 7 / 10 / 3 / 24 / 16 / 16 2 8 16 4 16 16 1 1 9 9 3 1 7 08 9x 6 20 28 / 36 / 8 / 10 / 3 / 24 / 16 / 16 2 16 16 4 16 16 1 3 1 11 1 1 3 10 10 x 4 22 37 / 39 / 7 / 11 / 5 / 33 / 18 / 16 8 2 16 2 16 16 1 3 15 11 1 1 3 12 10 x 7 22 37 / 39 / 9 / 11 / 5 / 33 / 18 / 16 8 16 16 2 16 16 1 3 5 11 7 1 3 16 11 x 10 22 47 / 39 / 13 / 12 / 16 / 43

Summary of the content on the page No. 12

Base unit dimensions (cont) 42BHC UNIT CORNER WEIGHTS (lb) 1 2 2 4 1 3 3 4 RIGHT HAND UNIT LEFT HAND UNIT RIGHT-HAND UNITS LEFT-HAND UNITS UNIT TOTAL CONFIGURATION 42BHC WEIGHT 12341234 No Heat 50 55 47 51 55 50 51 47 203 06 With Heat 50 58 59 67 58 50 67 59 234 No Heat 51 55 47 52 55 51 52 47 205 08 With Heat 50 59 59 68 59 50 68 59 236 No Heat 63 71 55 63 71 63 63 55 253 10 With Heat 62 76 68 81 76 62 81 68 287 No Heat 64 72 56 64 72 64 64 56 256 12 With Heat 63 76 68 82 76 63 82 68 290 No Hea

Summary of the content on the page No. 13

42BVC UNIT CORNER WEIGHTS (lb) 2 1 2 1 3 4 4 3 1 2 2 1 3 4 3 4 LEFT HAND UNIT RIGHT HAND UNIT RIGHT-HAND UNITS LEFT-HAND UNITS UNIT TOTAL CONFIGURATION 42BVC WEIGHT 12341234 No Heat 52 54 51 43 54 52 43 51 200 06 With Heat 58 65 61 47 65 58 47 61 231 No Heat 53 55 51 43 55 53 43 51 202 08 With Heat 58 66 62 47 66 58 47 62 233 No Heat 63 69 61 50 69 63 50 31 243 10 With Heat 69 81 72 54 81 69 54 72 277 No Heat 64 70 62 51 70 64 51 62 247 12 With Heat 70 82 73 55 82 70 55 73 281 No Heat 74 85 72 5

Summary of the content on the page No. 14

Accessory dimensions MIXING BOX B B W W 2 2 TOP VIEWS A 4 1 2.4 3 A 2.4 H H 2.4 A 3 2.4 1 A 4 C C BOTTOM/REAR INLET TOP/REAR INLET RIGHT HAND SIDE VIEWS NOTE: All dimensions in inches. DIMENSIONS (in.) 42BHC,BVC UNIT SIZE HW A B C 06 18.5 28 6 24 11 08 18.5 28 6 24 11 10 20.25 37 8 33 13 12 20.25 37 8 33 13 16 20.25 47 8 43 13 20 22.75 48 8 44 13 30 31.0 481044 15 40 31.0 481044 15 14

Summary of the content on the page No. 15

MIXING BOX RAILS 1 A 3 1 W D FRONT VIEW SIDE VIEW NOTE: All dimensions in inches. DIMENSIONS (in.) DIMENSIONS (in.) UNIT UNIT WD A WD A 42BHC06 28 51.6 16.1 42BVC06 28 35.5 16.1 42BHC08 28 51.6 16.1 42BVC08 28 35.5 16.1 42BHC10 37 55.2 18.1 42BVC10 37 39.5 18.1 42BHC12 37 55.2 18.1 42BVC12 37 39.5 18.1 42BHC16 47 55.4 18.1 42BVC16 47 39.5 18.1 42BHC20 48 57.8 18.1 42BVC20 48 41.5 18.1 42BHC30 48 59.8 20.1 42BVC30 48 47.5 20.1 42BHC40 62 63.0 20.1 42BVC40 62 47.5 20.1 15

Summary of the content on the page No. 16

Accessory dimensions (cont) VALVE PACKAGES Basic — Basic valve package includes 2 or 3-way Deluxe — Deluxe valve package includes a circuit valves with balancing valves and 2 ball valvs. setter and a strainer in addition to the components listed under basic valve package. F B A E D D C C A E B F NOTE: All dimensions in inches. PIPING CLOSE CONTROL VALVE SIZE AB CD E F Cv PACKAGE OFF 1 / in. 12.45 2.285 — — 15.25 7.41 3.5 25 psig 2 3 2-way / in. 12.71 3.156 — — 17.71 7.936 5 20 psig 4 1 in. 14.88

Summary of the content on the page No. 17

PIPING CONNECTION LOCATION DIAGRAM* CWR HWR D CWS C HWS B A Drain 2(51) 1-5/8(41) 0 RH Tell-Tale LH Tell-Tale LEGEND Use the table on the next page to determine the location of the piping connections. For example, on a size 20 unit with 4 rows and a right CWR — Cold Water Return hand connection, the location of the chilled water supply line is deter- CWS — Cold Water Supply 4 mined by G (6 in.) and B (7 / in.). 5 HWR — Hot Water Return HWS — Hot Water Supply LH — Left Hand RH — Right Hand SO — S

Summary of the content on the page No. 18

Accessory dimensions (cont) COIL ROWS DIMENSIONS (in.) 42BHC,BVC HEAT OPTIONS UNIT SIZE Cool Heat A B CDE F GH 0— —— — 1 1 15 4 13 /2 15 /2 77 5 /16 13 13 9 9 23 /16 15 /16 7 /16 7 /16 1 3 06/08 0— 6 /8 12 /4 — — — 1 1 3 3 1 6 13 /2 15 /2 9 /16 9 /16 8 /8 13 13 3 3 23 /16 15 /16 9 /4 9 /4 1 80 — — — — 10 /4 0— —— — 1 1 15 4 15 /8 17 /8 77 5 /16 7 7 9 9 25 /16 17 /16 7 /16 7 /16 3 3 10/12 0— 7 /4 14 /8 — — — 1 1 3 3 1 6 15 /8 17 /8 9 /16 9 /16 8 /8 27 7 3 3 25 /61 17 /16 9 /4 9 /4 1 80 — — — — 10

Summary of the content on the page No. 19

Application data Basic definitions UNIT HAND Unit hand — When facing the supply air outlet from the front of the unit (air blowing in your face), your right hand will be the right hand side of the unit and your left hand the left hand side of the unit. PIPING COMPONENTS CV FACTOR RATING* SYMBOL/SKETCH DESCRIPTION 1 3 /2 /4 PSI F MANUAL AIR VENT: Threaded brass needle valve with screwdriver slot for adjustment. Application — Body brazed into high point of heat- N/A N/A 400 100 ing and cooling coi

Summary of the content on the page No. 20

Application data (cont) PIPING COMPONENTS (cont) CV FACTOR RATING* SYMBOL/SKETCH DESCRIPTION 1 3 /2 /4 PSI F BALANCE VALVE: Variable water flow manual bal- ancing valve with screwdriver slot adjustment screw. Application — Often used in conjunctionwithtest 3.0 8.9 150 200 port fittings for water flow balancing. Balance by temperature differential or coil pressure drop (check specifications for service fittings required if balancing by pressure drop). May be used in 3-way valve bypass line to per


Alternative user manuals
# User manual Category Download
1 Carrier 13 50XP User manual Fan 3
2 Carrier 38AD024 User manual Fan 10
3 Carrier 38AB084 User manual Fan 7
4 Carrier 38AD028 User manual Fan 8
5 Carrier 38AB064 User manual Fan 7
6 Carrier 38AB054 User manual Fan 0
7 Carrier 38AD044 User manual Fan 1
8 Carrier 30GT015-035 User manual Fan 8
9 Carrier 38AD034 User manual Fan 5
10 Carrier 50JB034 User manual Fan 1
11 Carrier 50JB048 User manual Fan 1
12 Carrier 38AKS014-024 User manual Fan 23
13 Carrier 50JB044 User manual Fan 1
14 Carrier 50JB038 User manual Fan 1
15 Carrier AIR COOLED CONDENSING UNIT 38EH User manual Fan 0
16 A.O. Smith 160M User manual Fan 5
17 A.O. Smith 200M User manual Fan 2
18 A.O. Smith HW-120M User manual Fan 0
19 Acnodes EPSON PERFECTION 1200S User manual Fan 1
20 Aero Mist 67014 User manual Fan 0