Ariston GL 6+ user manual

User manual for the device Ariston GL 6+

Device: Ariston GL 6+
Category: Fan
Manufacturer: Ariston
Size: 0.16 MB
Added : 1/15/2014
Number of pages: 11
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Ariston GL 6+. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Ariston GL 6+.

For your convenience

If looking through the Ariston GL 6+ user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Ariston GL 6+ on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Ariston GL 6+ to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Ariston GL 6+ User manual - Online PDF
Advertisement
« Page 1 of 11 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Ariston GL 6+ but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Ariston GL 6+. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Mini Tank water heater
Electric undersink
Water heaters
GL 2.5 - GL 4 - GL 6+

Summary of the content on the page No. 2

IMPORTANT SAFETY INSTRUCTIONS When using electrical appliances, safety precautions to reduce the risk of fire, electric WARNING shock or injury to persons should be followed, including: 1. READ ALL INSTRUCTIONS BEFORE USING THIS WATER HEATER. 2. This water heater must be grounded. 3. Install or locate this water heater only in accordance with the provided installation instructions. 4. Use this water heater only for its intended use as described in this manual. 5. Contact a qualified electrician

Summary of the content on the page No. 3

Temperature & pressure FIG. 1/1 Hot water outlet relief valve, 3/4 NPT male 1/2 NPT male Cold water inlet 1/2 NPT male Temperature & pressure relief valve discharge 3/4 NPT female line to drain tapping for relief valve COMPONENT PARTS OF GL 2.5 - GL 4 FIG. 1/2 Temperature & pressure COMPONENT PARTS OF GL 6+ relief valve, 3/4 NPT male (Horizontal installation) Hot water outlet 3/4 NPT male 3/4 NPT male plug 3/4 NPT female tapping for Temperature & relief valve pressure relief valve discharge line

Summary of the content on the page No. 4

DIMENSIONS FOR GL 2.5 - GL 4 FIG. 2/1 14” 12 1/4” 10 1/4” 3 3/4” 6” 7 1/2” GL 2.5 1/2 NPT MALE 3 1/2” 3” 2 1/2” GL 4 FIG. 2/2 DIMENSIONS FOR GL 6+ (HORIZONTAL INSTALLATION) 14 1/2” 8 1/2” 4 1/2” 17 1/2” FIG. 2/3 DIMENSIONS FOR GL 6+ (VERTICAL INSTALLATION) 14 1/2” 11 1/2” 8 1/2” 3/4 NPT MALE 4 1/2” 2 1/2” 17 1/2” 5 14” 1” 5 1/2” 6 1/2” 17 1/2” 1” 17 1/2” 3/4 NPT MALE 3” 11 1/2”

Summary of the content on the page No. 5

General remarks CAUTION The manufacturer cannot be responsible for the damages caused by improper installation or by failure to follow instructions in this pamphlet. Comply with the installation instructions before completing electric connection. CAUTION The thermostat has been pre-set at the factory between 41°C (105° F) and 45° C (113° F). CAUTION Hydrogen gas can be produced in a hot water system served by this heater that has not been used for a long period of time (generally 2 weeks or more

Summary of the content on the page No. 6

Heater can sit on floor. Floor Mounting Pipe Connect the cold water inlet pipe to the inlet nipple (marked with a blue ring) and the hot connections water outlet pipe to the outlet nipple (marked with a red ring). To reduce the risk of excessive pressures and temperatures in this water heater, install CAUTION the supplied temperature and pressure protective equipment required by local codes but not less than a combination temperature and pressure relief valve certified by a nationally recognize

Summary of the content on the page No. 7

Maintenance instructions Note: Do not attempt to repair this water heater yourself. Call a service person for assistance. Always turn off the power supply to the heater prior to servicing or draining the heater. PERIODIC MAINTENANCE AND PARTS REPLACEMENT Note: For most of these operations, the water will have to be drained from the heater. For all of these operations the power supply needs to be shut off and the front cover removed. Remove cover plate V (fig. 3/4) using a thin screw-driver opera

Summary of the content on the page No. 8

Changing 1. Turn off power supply and drain the heater (see previous section). 2. Remove the heating element (see section on Removing the Heating Element). the heating 3. Install new element with gasket, making sure the gasket and element are positioned element correctly. Tighten the retaining nuts and make the wire connections. 4. Refill tank with water before restoring power. 1. Turn off power supply. Changing 2. Disconnect the 2 push/pull type wires on thermostat. the 3. Loosen the two brass

Summary of the content on the page No. 9

FIG. 3/1 N G FIG. 3/2 G FIG. 3/3 Z F X Y T B FIG. 3/4 FIG. 3/5 C V W F D 10

Summary of the content on the page No. 10

ARISTON • LIMITED 6 YEARS WARRANTY COVERAGE supplied with potable water. ARISTON, THROUGH ITS U.S. DISTRIBUTOR CONTROLLEDENERGYCORP., (hereinafter 5. The OWNER and not the Manufacturer or his CEC) guarantees this water heater to the representative shall be liable for and shall pay Owner (hereinafter “Owner”) of the water heater for all field charges for labor or other expenses at the original installation location against incurred in the removal and/or repair of the defects in material and workm

Summary of the content on the page No. 11

MTS MAKES USE OF RECYCLED PAPER COMMON SENSE HEAT & HOT WATER TECHNOLOGY Merloni TermoSanitari SpA Controlled Energy Corp. Viale Aristide Merloni, 45 340 Mad River Park 60044 Fabriano (AN) Waitsfield, VT 05673 Tel. 0732.6011 800-642-3111 Telefax. 0732.602331 802-496-4436 Telex 560160 Fax 802 496-6924 http://www.mtsgroup.net www.controlledenergy.com 29.1.60.542.1.01 0900 Litograf s.r.l.


Alternative user manuals
# User manual Category Download
1 Ariston GL 2.5 User manual Fan 1
2 Ariston GL 4 User manual Fan 5
3 Ariston Heaters User manual Fan 3
4 A.O. Smith 160M User manual Fan 5
5 A.O. Smith 200M User manual Fan 2
6 A.O. Smith HW-120M User manual Fan 0
7 Acnodes EPSON PERFECTION 1200S User manual Fan 1
8 Aero Mist 67014 User manual Fan 0
9 Air King 1VN45 User manual Fan 0
10 Air King 4TM61C User manual Fan 0
11 A.O. Smith 225M User manual Fan 1
12 Able Planet 620DuN User manual Fan 7
13 Air King 4YN46C User manual Fan 0
14 Air King 4C796E User manual Fan 0
15 Air King 3C614D User manual Fan 0