Mr. Heater MH35LP user manual

User manual for the device Mr. Heater MH35LP

Device: Mr. Heater MH35LP
Category: Electric Heater
Manufacturer: Mr. Heater
Size: 0.21 MB
Added : 3/11/2013
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Mr. Heater MH35LP. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Mr. Heater MH35LP.

For your convenience

If looking through the Mr. Heater MH35LP user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Mr. Heater MH35LP on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Mr. Heater MH35LP to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Mr. Heater MH35LP User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Mr. Heater MH35LP but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Mr. Heater MH35LP. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

MODEL
MODEL
START SN#0253700 -
OPERATING INSTRUCTIONS AND OWNER’S MANUAL
READ INSTRUCTIONS CAREFULLY: Read and
MR. HEATER HEATSTAR
follow all instructions. Place instructions in a
safe place for future reference. Do not allow
HS35LP
anyone who has not read these instructions to
MH35LP
assemble, light, adjust or operate the heater.
GAS-FIRED INFRA-RED
PORTABLE CONSTRUCTION HEATER
DO NOT LEAVE HEATER UNATTENDED OR IN OPERATION WHILE SLEEPING
CYLINDER NOT INCLUDED
GENERAL HAZARD WARNING:
FAILURE TO

Summary of the content on the page No. 2

SPECIFICATIONS VENTILATION MODEL NO. ...............35LP 35LP WARNING GAS TYPE ................LP-Gas MAX. INLET THIS APPLIANCE IS UNVENTED AND MUST BE PRESSURE. ......... 27.5” W.C. USED ONLY IN A WELL VENTILATED AREA. MIN. INLET PRESSURE.......... 27.5” W.C. The flow of combustion and ventilation air must not be MANIFOLD obstructed. DO NOT use in a tightly enclosed area. Any PRESSURE .......... 25.5” W.C. combustion process requires and consumes oxygen, and may produce carbon monoxide. This he

Summary of the content on the page No. 3

The minimum ambient temperature rating for this heater is 20 GENERAL INFORMATION degrees F. A. Your portable gas-fired infra-red heater comes fully This heater incorporates a “Tip Over” switch which automatically assembled and is tested at the factory for proper gas and shuts off the burner in the event of tipping. Ensure that this input as stated on the nameplate. switch is in the vertical position and is secured with the screws B. Each heater is equipped with a 100% safety shutoff, push provid

Summary of the content on the page No. 4

The connection of Model 35LP to an LP-Gas cylinder must be made CAUTION in a well ventilated area using the regulator and hose assembly supplied with the appliance. DO NOT attempt to adjust this DO NOT PLACE CLOTHING OR regulator. It has been preset at the factory to provide safe and OTHER COMBUSTIBLE MATERIALS proper operation of the appliance. Use a 7/8” open end wrench to ON THIS APPLIANCE. connect the POL fitting (supplied with the LP regulator) to the LP- DO NOT operate this heater if any p

Summary of the content on the page No. 5

Shut-down instructions: TROUBLESHOOTING INFORMATION: (Model 35LP) To turn the heater OFF: 1. Close the LP-Gas supply cylinder valve. If burner lights, but goes out when button is released. 2. Observe the burner until flame is extinguished. CHECK • Loose wires on tipover switch. (see Fig. 4) 3. Listen for closure of the safety valve. • Loose lead wire and repair wires if necessary. 4. IMPORTANT: DO NOT re-open the LP-Gas supply cylinder valve before the safety valve closes. • Loose thermocouple a

Summary of the content on the page No. 6

Tip Over Switch 1 Magnetic Portion of Control 4 Thermocouple 5 Tip Over Switch Adaptor Leads Leads Control Junction Block Adaptor Kit 6 Heater Bottom Figure 4 REPLACEMENT PARTS LIST Tip-Over Switch Arrangement REF. # ....... ITEM# DESCRIPTION NOTE: The purpose of the tip-over Switch is to stop the flow of gas 1 .............. 23525 ......... CONT M-N SS PORT 3/8MPXI/4MP when heater is accidentally knocked over. When and if the heater is knocked over, simply stand heater up. 2 .............. 2352

Summary of the content on the page No. 7

Gas-Fired Infra-Red Portable Construction Heater • Model #35LP 13 15 3 2 9 4 16 5 12 8 10 11 1 14 6 7 IF SERVICE IS REQUIRED PLEASE DO NOT RETURN THIS APPLIANCE TO YOUR STORE For information regarding service, please call our Toll-Free Number: 1-800-251-0001. Our office hours are 8:30 AM to 5:00 PM, Eastern Time Zone, Monday through Friday Please include the model number, date of purchase and description of problem in all communication. Enerco Group, Inc. | Gas-Fired Infra-Red Portable

Summary of the content on the page No. 8

MODEL MODEL OPERATING INSTRUCTIONS AND OWNER’S MANUAL READ INSTRUCTIONS CAREFULLY: Read and MR. HEATER HEATSTAR follow all instructions. Place instructions in a safe place for future reference. Do not allow HS35LP anyone who has not read these instructions to MH35LP assemble, light, adjust or operate the heater. WARNING: USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE DIRECT FROM THE FACTORY AND MUST BE INSTALLED

Summary of the content on the page No. 9

MANUEL DE L'UTILISATEUR ET INSTRUCTIONS D'UTILISATION REMARQUE : lisez et suivez les instructions d'utilisation. Rangez le manuel de l'utilisateur dans un endroit sûr aux MR. HEATER HEATSTAR fins de référence ultérieure. NE LAISSEZ PERSONNE qui o n'a pas lu le manuel de l'utilisateur tenter de monter, de o N de modèles N de modèles mettre en marche, de régler ou de faire fonctionner MH35LP HS35LP l'appareil de chauffage. MISE EN GARDE UTILISEZ SEULEMENT LES PIÈCES DE REMPLACEMENT DU FABRICANT. L

Summary of the content on the page No. 10

Enerco Group, Inc. • appareil de chauffage portatif à infrarouge fonctionnant au gaz • Modèle no 35LP 13 15 3 2 9 16 4 5 12 8 10 1 11 14 6 7 SERVICE À LA CLIENTÈLE N'ENVOYEZ PAS LE PRÉSENT APPAREIL DE CHAUFFAGE À VOTRE MAGASIN Pour obtenir de plus amples informations sur le service à la clientèle, veuillez composer notre numéro sans frais : (800) 251-0001. Nos heures d'ouverture sont de 8 h 30 à 17 h , heure de l'Est, du lundi au vendredi Veuillez fournir le numéro du modèle, la date d'achat et

Summary of the content on the page No. 11

Interrupteur de bascule 1 Partie magnétique de la pièce de contrôle 4 Thermocouple 5 Fils de l'interrupteur de bascule Fils de l'adaptateur Pièce de contrôle Joint d'adaptateur 6 Partie inférieure du brûleur Figure 4 LISTE DES PIÈCES DE REMPLACEMENT Interrupteur de bascule o o N RÉF. .... N Article DESCRIPTION REMARQUE : L'interrupteur de bascule sert à bloquer 1 .............. 23525 ......... VALVE DE CONTRÔLE, ARRÊT automatiquement l'alimentation en gaz si l'appareil bascule ou est

Summary of the content on the page No. 12

Instructions d'arrêt DÉPANNAGE (Modèle 35LP) Pour éteindre l'appareil de chauffage : Le brûleur s'allume, mais s'éteint lorsque le bouton est relâché. 1. Fermez la valve d'alimentation de la bonbonne de gaz. VÉRIFIEZ SI : 2. Observez le brûleur jusqu'à ce que la flamme s'éteigne. • Les fils branchés à l'interrupteur de bascule sont 3. Soyez attentif au bruit provoqué par la fermeture de la bien fixés. (voir fig. 4) valve de sécurité. • Tous les fils sont bien fixés. • Le thermocouple est bien fi

Summary of the content on the page No. 13

Le branchement du modèle MH35LP/HS35LP à une bonbonne de gaz AVERTISSEMENT propane liquéfié doit être effectué dans un endroit bien aéré à l'aide de la tuyauterie et l'ensemble de régulation fournis avec l'appareil. NE DÉPOSEZ PAS DE VÊTEMENT OU N'ESSAYEZ PAS de régler ce régulateur. Celui-ci a été réglé en usine AUTRE MATÉRIAU COMBUSTIBLE SUR afin d'assurer un fonctionnement adéquat et sécuritaire de l'appareil. L'APPAREIL DE CHAUFFAGE. Utilisez une clé à fourche 7/8 po pour bancher la pièce de

Summary of the content on the page No. 14

La température minimale ambiante pour utiliser le présent appareil est INFORMATIONS GÉNÉRALES de 20 degrés Fahrenheit (-6 degrés Celsius). A. Votre appareil de chauffage portatif Enerco/MR. HEATER est livré L'appareil est muni d'un interrupteur « de bascule » qui coupe entièrement assemblé. Il a été testé en usine avec la pression automatiquement l'alimentation en gaz si l'appareil bascule. Assurez- d'admission et le type de gaz appropriés, comme indiqué sur la vous que cet interrupteur est en p

Summary of the content on the page No. 15

SPÉCIFICATIONS VENTILATION O MODÈLE N . ......... MH35LP HS35LP TYPE DE GAZ............Gaz propane liquéfié MISE EN GARDE PRESSION D'ADMISSION LE PRÉSENT APPAREIL N'EST PAS VENTILÉ ET MAXIMALE.............27.5 pouces d'eau (in. w.c.) DOIT ÊTRE UTILISÉ SEULEMENT DANS UN PRESSION D'ADMISSION ENDROIT BIEN AÉRÉ. MINIMALE..............27.5 pouces d'eau (in. w.c.) PRESSION La circulation d'air et le flux de combustion ne doivent pas être D'ADMISSION.........25.5 pouces d'eau (in. w.c.) ralentis. N'UTI

Summary of the content on the page No. 16

START SN#0253700 - MANUEL DE L'UTILISATEUR ET INSTRUCTIONS D'UTILISATION REMARQUE : lisez et suivez les instructions d'utilisation. Rangez le manuel de l'utilisateur dans un endroit sûr aux MR. HEATER HEATSTAR fins de référence ultérieure. NE LAISSEZ PERSONNE qui o n'a pas lu le manuel de l'utilisateur tenter de monter, de o N de modèles N de modèles mettre en marche, de régler ou de faire fonctionner MH35LP HS35LP l'appareil de chauffage. APPAREIL DE CHAUFFAGE PORTATIF À INFRAROUGE FONCTIONNANT


Alternative user manuals
# User manual Category Download
1 Mr. Heater MH35LP Operating instructions Space heaters 0
2 Mr. Heater HS55FAV User manual Electric Heater 2
3 Mr. Heater HS35LP User manual Electric Heater 0
4 Mr. Heater Gas-Fired Infra-Red Portable Heater MH45T User manual Electric Heater 2
5 Mr. Heater MH12 User manual Electric Heater 2
6 Mr. Heater HS85FAV User manual Electric Heater 0
7 Mr. Heater HS125FAV User manual Electric Heater 0
8 Mr. Heater MH12CS User manual Electric Heater 0
9 Mr. Heater MH12C User manual Electric Heater 2
10 Mr. Heater MH125FAV User manual Electric Heater 1
11 Mr. Heater MH85FAV User manual Electric Heater 0
12 Mr. Heater MH35LPTS User manual Electric Heater 0
13 Mr. Heater MH55FAV User manual Electric Heater 0
14 Mr. Heater MH9BX User manual Electric Heater 7
15 Mr. Heater TS125FAV User manual Electric Heater 0
16 A.O. Smith AH - 290 User manual Electric Heater 6
17 A.O. Smith AHD 290 User manual Electric Heater 7
18 A.O. Smith AHDS 290 User manual Electric Heater 0
19 A.O. Smith ST 3000 User manual Electric Heater 5
20 A.O. Smith WATER HEATERS User manual Electric Heater 13