Graco VISCON HP 309524L user manual

User manual for the device Graco VISCON HP 309524L

Device: Graco VISCON HP 309524L
Category: Electric Heater
Manufacturer: Graco
Size: 1.2 MB
Added : 6/8/2014
Number of pages: 30
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Graco VISCON HP 309524L. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Graco VISCON HP 309524L.

For your convenience

If looking through the Graco VISCON HP 309524L user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Graco VISCON HP 309524L on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Graco VISCON HP 309524L to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Graco VISCON HP 309524L User manual - Online PDF
Advertisement
« Page 1 of 30 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Graco VISCON HP 309524L but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Graco VISCON HP 309524L. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Instructions
High Pressure Fluid Heater
VISCON HP
309524L
Used for variable heating of fluids.
7250 psi (50 MPa, 500 bar) Maximum Working Pressure
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
See page 2 for model numbers, descriptions, and
approvals information.
See page 3 for Table of Contents.
TI12338A
Hazardous Location Heater shown

Summary of the content on the page No. 2

Models Models Hazardous Location Heaters Part No. Series VAC (50/60 Hz single phase) / Watts / Amps Approvals 245848 A 120 / 2300 / 19.2 II 2 G 245863 A 240 / 4000 / 16.7 Approved Exd II T2 482°F (250°C) 245864 A 480 / 4000 / 8.30 Certificate No. ISSeP 07ATEX034X Approved to EN 60079-0:2006 (IEC 60079-0:2004) and EN 60079-1:2007 (IEC 60079-1:2007) for Hazardous Locations, Temp Code T2 482°F (250°C). See Technical Data, page 28, for additional information. CSA Certified and FM Approved as fl

Summary of the content on the page No. 3

Contents Contents Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Manual Conventions . . . . . . . . . . . . . . . . . . . . . . . . 3 Hazardous Location Heaters . . . . . . . . . . . . . . . 22 Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Non-Hazardous Location Heaters . . . . . . . . . . . 24 Installation . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 4

Warning WARNING SKIN INJECTION HAZARD High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment. � Do not point the gun at anyone or at any part of the body. � Do not put your hand or fingers over the gun fluid nozzle. � Do not stop or deflect leaks with your hand, body, glove, or rag. � Do not “blow back” fluid; this is not an air spray system. � F

Summary of the content on the page No. 5

Warning WARNING EQUIPMENT MISUSE HAZARD Misuse can cause serious injury or death. � For professional use only. � Use equipment only for its intended purpose. Call your Graco distributor for information. � Read manuals, warnings, tags, and labels before operating equipment. Follow instructions. � Check equipment daily. Repair or replace worn or damaged parts immediately. � Do not alter or modify equipment. Use only Graco parts and accessories. � Do not exceed the maximum working pressure or temp

Summary of the content on the page No. 6

Installation Installation Typical Installation Drawing The typical installation drawing is only a guide. Your Graco distributor can assist in designing your system. Z Q F G H J Y A B C D E K X P N V R L M T U W S 05486-524 Key: A Bleed-type Master Air Valve JPower Cable S Back Pressure Valve B Air Filter K Heater T Fluid Shutoff Valve C Air Regulator and Gauge L Fluid Filter U Director Valve D Air Line Lubricator M Drain Valve VDrain Back Tube E Pump Runaway Valve N Fluid Pressure Regulator W S

Summary of the content on the page No. 7

Installation I Selecting Tubing WARNING Fluid loses some heat through the tubing or hose between the heater and spray gun. Locate heater close to the spray area to minimize heat loss through plumb- Read warnings, pages 4-5. ing. � Select system components that meet temper- The chart in FIG. 2 shows a heat loss curve for 3 com- ature and pressure ratings listed in Technical mon types of tubing. Data, page 28. The heater’s normal output range is adjustable from 84-220°F Chart Notes: (29-104°

Summary of the content on the page No. 8

Installation Mounting Heater � The heater has a surface temperature of T2 6 in. 152.4 mm (482°F, 250°C). Follow temperature code when locating heater. See Technical Data, 5 in. page 28, for more temperature code informa- 127 mm tion. � Heater controls must be easily accessible. 6 � The mounting surface must be able to support 5 the weight of the heater and fluid, and any YY stress caused during operation. CC BB Wall Mounting Need wall bracket 192585 or 183982. See Acces- 05442 sories, pag

Summary of the content on the page No. 9

Installation Cart Mounting WARNING (FIG. 5) You need to have 2 each of cart mounting bar To avoid rupturing a component, which can cause seri- 183485 and clamp 183484. See Accessories, ous injury, including amputation; read warnings, page page 26, to order. 4, and follow the instructions below. 1. Place clamps (AA) around the cart vertical post 2. Provide a means for adequately handling fluid (DD) and secure to the heater mounting bars (ZZ) expansion caused by heat. Options include: with

Summary of the content on the page No. 10

Installation Hazardous Location Installation Electrical Connections Requirements 1. The heater connection must be made using one of WARNING the following options: a. Cable entries of a certified flameproof model. Read warnings, page 4. Install heater in compliance b. Threaded metal conduits. with all applicable codes and regulations. If this option is used, a stopping box with CAUTION compound filling of a certified flameproof model must be placed at the entry of the To help prevent dam

Summary of the content on the page No. 11

Installation Wall Mounted Wiring Cart Mounted Wiring Mount a 2-pole, explosion-proof electric switch (H) near Connect a plug that meets the electrical codes for your the heater. See FIG. 7. The switch must meet the electri- location. See FIG. 8. cal codes for your location. Also use the correct cable and plug. H 4 4 9 1 4 9 2 4 9 1 4 9 2 4 3 4 8 1 3 Power terminal Ground terminal 3 4 8 2 4 Neutral terminal or 2nd Tighten all terminal nuts to power terminal 30 in-lb (3.4 N�m) 05547-524 1 3 Pow

Summary of the content on the page No. 12

Installation To find your fluid’s Under-Boil temperature: Determining Proper Fluid 1. Pour a small sample into a heat-proof container. Temperature 2. Measure and record the fluid temperature and vis- cosity using a No. 2 Zahn cup. CAUTION 3. Heat water in a large container to 200°F (93°C). Operating the heater at its highest setting, over 180°F Place the sample in the water. (82°C), for long periods of time decreases the heater life and can cause fluid to dry out; which can clog the 4. At

Summary of the content on the page No. 13

Installation 60 Typical high-solid paint 50 Typical enamel paint 40 nU 1 30 Typical spray viscosities nU 2 20 10 o C 15 25 35 45 55 65 o (60) (80) (100) (120) (140) ( F) Temperature FIG. 10: Effect of Temperature on Viscosity The chart in FIG. 10 shows the effect of temperature in Once the fluid is reduced to about 34 on the chart, vis- reducing two fluids to a sprayable viscosity, between 20 cosity reduction begins to level off and temperature will and 34 seconds using a No. 2 Zahn cup. not s

Summary of the content on the page No. 14

Operation Operation Pressure Relief Procedure Initial Flushing WARNING WARNING Read warnings, page 4. Read warnings, page 4. Follow Pressure Relief Procedure when you stop The heater was tested with lightweight oil, which needs spraying, and before cleaning, checking, or servicing to be flushed out before using the equipment. Ensure equipment. main power is off and heater is cool before flushing. Use a compatible solvent, and follow flushing instructions in 1. Engage the gun safety lock. yo

Summary of the content on the page No. 15

Operation Setting Heater Control Adjusting for Spraying (Refer to FIG. 11) CAUTION 1. Set the heater control knob (33) to a trial setpoint of 4 or 5. Operating the heater at its highest setting, over 180°F (82°C), for long periods of time decreases the heater 2. Start the pump and circulate fluid through the sys- life and can cause fluid to dry out; which can clog the tem at very low pressure, about 10-12 oz/min heater and result in a poor finish. (0.30-0.35 liter/min). 1. Adjust pump press

Summary of the content on the page No. 16

Maintenance Maintenance Unclogging Fluid Passages WARNING (FIG. 13) 1. Drain the heater. Read warnings, pages 4 and 5. Make sure the main power is off and heater is cool before doing mainte- 2. Remove the heater block (3) from the heater hous- nance. ing. See Heater Block, page 20. 3. Pour a high strength, compatible solvent into the Flushing heater tube to soften the clog. Clogged fluid passages are difficult to clean and reduce 4. Flush out the clog. heating efficiency, flow rate, and pres

Summary of the content on the page No. 17

Troubleshooting Troubleshooting Problem Cause Solution Heater will not heat. No current. Check circuit and fuses. Check continuity of primary thermo- stat (24), backup thermostat (10), and thermal limit sensor (15). Check continuity of thermostat (10) and heater block (3) terminals - Page 18. Burned out heater block (3). Replace block - Page 20. Blown heat limiter (15). Check continuity of primary thermo- stat (24) and backup thermostat (10). Replace thermostats if necessary when replacing

Summary of the content on the page No. 18

Repair Repair WARNING CAUTION To avoid damaging capillary tube (GG), which can cause heater malfunction, do not kink or nick the tube. Read warnings, pages 4-5. Make sure the main power To avoid shorting out the heater, do not allow capillary is off and heater is cool before repairing. tube to contact the block terminal (3A). Follow step 10, below. Hazardous Location Heaters: See FIG. 15 & 17 10. Liberally apply thermal lubricant (part no. 110009) to Non-hazardous Location Heaters: See FIG

Summary of the content on the page No. 19

Repair HH 3B REF. 10 REF. 19 2 6 L1 5 9A 18 19 GG 3A 9B 16 63 FF 15 3 62 24 15 27 25 35 52 L2 GND 63 1 53 26 HH Wiring Diagram TI12339 62 28 1 10 16 1 3A EE 54 55 1 Apply thermal lubricant 51 2 50 Torque to 89 in-lb (10 N�m) 48 20 3 Torque nuts (62) to 10-12 in-lb (1.1-1.3 N�m) TI12335C FIG. 15: Thermostat Repair – Hazardous Location Heaters 3B 52 2 REF. 19 HH REF. 10 18 GND 3A 47 L1 16 15 FF GG 19 63 24 3 62 26 15 28 27 35 9B 9A L2 1 Wiring Diagram 25 16 HH 62 63 1 1 10 Apply thermal lubricant

Summary of the content on the page No. 20

Repair Thermal Limit Sensor Heater Block 1. Follow Pressure Relief Procedure, page 14. CAUTION 2. Remove housing cover (18). To avoid damaging the capillary tube (GG), which can cause heater malfunction, do not kink or nick the tube. 3. Hazardous Location Heater only: Remove electrical junction box cover (4). To avoid shorting out the heater, do not allow the cap- illary tube to contact the block terminal (3A). 4. Hazardous Location Heater only: In the junction box (1B), disconnect the mai


Alternative user manuals
# User manual Category Download
1 A.O. Smith AH - 290 User manual Electric Heater 6
2 A.O. Smith AHD 290 User manual Electric Heater 7
3 A.O. Smith AHDS 290 User manual Electric Heater 0
4 A.O. Smith ST 3000 User manual Electric Heater 5
5 A.O. Smith WATER HEATERS User manual Electric Heater 13
6 A.O. Smith ST 1500 User manual Electric Heater 1
7 ACCO Brands H212 User manual Electric Heater 4
8 ACCO Brands H312 User manual Electric Heater 28
9 Adams Sun Heat Low Intensity Infra-Red Heater User manual Electric Heater 1
10 Addonics Technologies RAID TOWER IX RT93DAHXML User manual Electric Heater 1
11 Addonics Technologies RAID TOWER IX RT93DAHX User manual Electric Heater 1
12 AEG WSP 6010 User manual Electric Heater 85
13 AEG WSP 4010 User manual Electric Heater 56
14 Acroprint ES700 User manual Electric Heater 0
15 AEG WSP 5010 User manual Electric Heater 72