Empire Comfort Systems DV33IN33L user manual

User manual for the device Empire Comfort Systems DV33IN33L

Device: Empire Comfort Systems DV33IN33L
Category: Electric Heater
Manufacturer: Empire Comfort Systems
Size: 3.08 MB
Added : 6/21/2014
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Empire Comfort Systems DV33IN33L. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Empire Comfort Systems DV33IN33L.

For your convenience

If looking through the Empire Comfort Systems DV33IN33L user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Empire Comfort Systems DV33IN33L on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Empire Comfort Systems DV33IN33L to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Empire Comfort Systems DV33IN33L User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Empire Comfort Systems DV33IN33L but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Empire Comfort Systems DV33IN33L. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION INSTRUCTIONS
AND
OWNER’S MANUAL
INNSBROOK FIREPLACE INSERT
DIRECT VENT
GAS FIREPLACE HEATER
MODEL SERIES
DV25IN33L(N,P)-1
DV33IN33L(N,P)-1
DV35IN33L(N,P)-1
GAS-FIRED
UL FILE NO. MH30033
Installer: Leave this manual with the appli-
ance.
Consumer: Retain this manual for future refer-
ence.
WARNING: If the information in these instruc-
tions are not followed exactly, a fire or explosion
may result causing property damage, personal
injury or loss of life.
— Do not store or use gasoli

Summary of the content on the page No. 2

TABLE OF CONTENTS SECTION PAGE Important Safety Information .................................................................................................3 Safety Information for Users of LP Gas .................................................................................4 Introduction ............................................................................................................................5 Specifications ..................................................................

Summary of the content on the page No. 3

IMPORTANT SAFETY INFORMATION Before enclosing the vent pipe assembly, operate the appliance to ensure it is venting properly. DO NOT OPERATE THIS APPLIANCE WITHOUT GLASS FRONT PANEL INSTALLED • Children and adults should be alerted to the hazards • Keep the area around your appliance clear of of high surface temperatures and should stay away combustible materials, gasoline and other flammable to avoid burns or clothing ignition. vapor and liquids. • Young children should be carefully supervise

Summary of the content on the page No. 4

SAFETY INFORMATION FOR USERS OF LP GAS Propane (LP-Gas) is a flammable gas which can cause fires by point with the members of your household. Someday and explosions. In its natural state, propane is odorless and when there may not be a minute to lose, everyone’s safety colorless. You may not know all the following safety precau- will depend on knowing exactly what to do. If, after read- tions which can protect both you and your family from an ing the following information, you feel you still nee

Summary of the content on the page No. 5

INTRODUCTION Instructions to Installer Warning: ANY CHANGE TO THIS FIREPLACE OR ITS 1. Installer must leave instruction manual with owner after CONTROLS CAN BE DANGEROUS. installation. Improper installation or use of the fireplace can cause 2. Installer must have owner fill out and mail warranty card supplied serious injury or death from fire, burns, explosions, or with the fireplace. carbon monoxide poisoning. 3. Installer should show owner how to start and operate the fireplace. Any alteratio

Summary of the content on the page No. 6

SPECIFICATIONS DV25IN33L MODELS LP Nat Remote Control Description Accessories Input Btu/hr Maximum 25,000 25,000 FRBC Millivolt Battery Remote ON/OFF Btu/hr Minimum 17,000 17,000 FRBTC Millivolt Battery Remote T-Stat KWH (Maximum) 7.30 7.30 TMV Millivolt WIRELESS Wall Thermostat (Minimum) 5.00 5.00 TRW Millivolt Reed Switch Wall Thermostat Orifice #53 (0.0596) #42 (0.0935) Air Shutter Opening Full Open 1/8” DV33IN33L MODELS LP Nat Input Btu/hr Maximum 33,000 33,000 Surround Ki

Summary of the content on the page No. 7

FIREPLACE INSERT DIMENSIONS • Whether optional accessories - devices such as a wall switch When planning a fireplace insert installation, it’s necessary to or remote control - are desired. determine: • Electrical supply requirements for blower. • The vent system configuration to be used. • Proper opening size of fireplace required for installation of • Gas supply piping. the fireplace insert. DV FIREPLACE INSERT DIMENSIONS MODEL A B C D E F G H I J K L M N DV25IN 19 3/8” 28 14 1/2” 11 1/8” 25 1/4

Summary of the content on the page No. 8

MANTLE AND TRIM CLEARANCES 12 ” 10 ” COMBUSTIBLE MANTEL/TRIM AREA 23 ” 1 3/4 ” 1 1 ” 8” MINIMUM CLEARANCE T O PERPENDICULAR COMBUSTIBLE SIDE-W ALL (FROM EDGE OF DOOR FRAME) Figure 3 Figure 4 Combustible Material No greeting cards, stockings or ornamentation of any type should be placed on or attached to the fireplace. The flow of heat can ignite combustibles. Page 8 23015-3-0707

Summary of the content on the page No. 9

GAS SUPPLY The gas pipeline can be brought in through the right or left side of Installing the Main Gas Cock the appliance. The insert has a Flexline with shutoff valve located Each appliance should have its own manual gas cock. on the right side when facing the unit. See Figures 5 and 6. Consult A manual main gas cock should be located in the vicinity of the the current National Fuel Gas Code, ANSI Z223.1 CAN/CGA-B149 unit. Where none exists, or where its size or location is not ad- (.1 or .2

Summary of the content on the page No. 10

VENTING AND INSTALLATION 1. Before beginning, remove glass door and log package from 7. To assure top performance, safety and efficiency, inserts must unit. Also check to make sure there is no hidden damage to be installed with an approved flue liner as per CAN/CGA the unit. Take a minute and plan out the gas, venting and elec- B-149 or National Fuel Code ANSI Z223 and these instruc- trical route. It is best to start with the gas line first, followed tions. by the chimney liner and electrical sup

Summary of the content on the page No. 11

VENTING AND INSTALLATION Connecting the Vent Pipe Vent System Approvals Figure 8 shows the vent termination caps and systems approved Caution: Sharp edges. Always use gloves when installing. for use with these models. Approved vent system terminations Install the 3-inch flexible vent pipes down through the chimney. are labeled for identification. 3-inch diameter listed flexible aluminum or stainless steel gas vent is used for both the incoming Attach the pipe-to-cap adaptor to the termination ca

Summary of the content on the page No. 12

VENTING AND INSTALLATION RECT ANGULAR TERMINA TION CAP (DVVK3FV KIT) NOTE: LONG EXTENSIO N TUBE FOR INLET VENT ROUND CONNECTION. TERMINA TION CAP (DVKI KIT) ROUND CO-LINEAR T O CO-AXIAL ADAPT OR VENT CLAMPS RET AINER SCREWS M A Y USE HIGH TEM P BE INST ALLED THROUGH SEALANT ON VENT THE VENT CLAMPS T O CONNECTIONS ENSURE POSITIVE SECUREMENT OF VENTING. INT AKE VENT 10’ MINIMUM 35’ MAXIMUM FLUE EXHAUST VENT OPTIONAL ON/OFF SWITCH LOCA TION VENT CLAMPS OPTIONAL ON/OFF SWITCH LOCA TION USE HIGH TEM

Summary of the content on the page No. 13

VERTICAL TERMINATION Determining Minimum Vent Height Above the Roof. Vertical Through the Roof Applications The Gas Fireplace Insert has been approved for: WARNING: Major U.S. building codes specify minimum a) Vertical installations up to 35 feet in height (top of insert to chimney and/or vent height above the roof top. These minimum cap). heights are necessary in the interest of safety. These specifica- b) Two sets of 45 degree elbow offsets (bends in flexvent) within tions are summarized in

Summary of the content on the page No. 14

ALTERNATE ON/OFF SWITCH INSTALLATION WIRING THE FIREPLACE Note: Electrical wiring must be installed by a licensed electrician. CAUTION: DISCONNECT REMOTE CONTROLS IF YOU ARE AB- SENT FOR EXTENDED TIME PERIODS. THIS WILL PREVENT ACCIDENTAL FIREPLACE OPERATION. Installation of Alternate Surround Panel ON/OFF Switch An ON/OFF switch and wire assembly are provided. They are included in the instruction packet. Do not cut wire or insulation on metal edges. Note: Refer to surround panel installation

Summary of the content on the page No. 15

SURROUND PANEL INSTALLATION INSTALLING THE TRIM SURROUNDS Combustible materials MUST NEVER overlap onto the front face. WARNING: WHEN FINISHING THE FIREPLACE INSERT, NEVER OBSTRUCT OR MODIFY THE AIR INLET/OUTLET LOUVERS ON THE FIREPLACE IN- SERT IN ANY MANNER. NOTE: INST ALL SURROUND P ANELS SO TH A T TH E T OP P ANE L RETURN FLANGE SLIDE’ S OVER TH E T OP FLANG E O N TH E INSER T Figure 15 ENGAGE SID E P ANEL HOOK S W ITH TH E NOTCHE S P ROVIDED O N THE SIDE FLANGE S SURROUND P ANEL ASSEMBL

Summary of the content on the page No. 16

BLOWER ACCESSORY INFORMATION The appliance, when installed must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code. U.S. Installations, follow local codes and the National Electrical Code, ANSI/NFPA No. 70. Should this blower require servicing, the power supply must be disconnected. For rewiring of any replacement components, re- fer to Figures 16 and 17 and the parts list on page 25. B

Summary of the content on the page No. 17

LOG PLACEMENT Before you begin: This fireplace insert is supplied with a set of seven ce- 13. Replace the glass door assembly onto the fireplace insert. ramic fiber logs. Do not handle these logs with your bare hands. Always 14. Secure the glass door with the two spring clamps located under the wear gloves to prevent skin irritation from ceramic fibers. After handling firebox. logs, wash your hands gently with soap and water to remove any traces 15. Re-install the upper and lower louver assemblies b

Summary of the content on the page No. 18

OPERATING INSTRUCTIONS 750 Millivolt System Initial Lighting The standing pilot (750 millivolt system) is a continuous burning Upon completing the gas line or turning the gas valve on after it pilot. The pilot remains ON even when the main burner is OFF. has been in the “OFF” position, a small amount of air will be in the lines. When first lighting the fireplace, it will take a few minutes When you ignite the pilot, the thermopile produces millivolts for the lines to purge themselves of this a

Summary of the content on the page No. 19

STANDING PILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. • If you cannot reach your gas supplier, call the fire depart- When lighting the pilot, follow these instructions exactly. ment. B. Before lighting smell all around the appliance area for gas. C. Use only your hand t

Summary of the content on the page No. 20

STANDING PILOT WIRING For Standing Pilot Ignition Wiring Optional Wall Switch Position the wall switch in the desired position on a wall. Run a Appliance Requirements maximum of 25 feet (7.8m) or less length of 18 A.W.G. minimum wire and connect it to the fireplace valve pigtails. WARNING: DO NOT CONNECT 110-120 VAC TO THE GAS CONTROL VALVE OR THE APPLIANCE WILL MALFUNCTION AND THE VALVE WILL BE DE- WARNING: DO NOT CONNECT THE 110-120 VAC STROYED. TO THE WALL SWITCH OR THE CONTROL VALVE WIL


Alternative user manuals
# User manual Category Download
1 Empire Comfort Systems 2 User manual Electric Heater 0
2 Empire Comfort Systems BF-20-2 User manual Electric Heater 1
3 Empire Comfort Systems 3)(N User manual Electric Heater 0
4 Empire Comfort Systems CIVF-25-2 User manual Electric Heater 0
5 Empire Comfort Systems BF-30-2 User manual Electric Heater 0
6 Empire Comfort Systems BF-10-2 User manual Electric Heater 0
7 Empire Comfort Systems CIVF-25-21 User manual Electric Heater 1
8 Empire Comfort Systems DV25IN33L User manual Electric Heater 0
9 Empire Comfort Systems DVD32FP3 User manual Electric Heater 0
10 Empire Comfort Systems LS-18H-1 User manual Electric Heater 0
11 Empire Comfort Systems DV35IN33L User manual Electric Heater 0
12 Empire Comfort Systems LS-18B2-1 User manual Electric Heater 1
13 Empire Comfort Systems DVP42FP User manual Electric Heater 1
14 Empire Comfort Systems LS-18RS-1 User manual Electric Heater 0
15 Empire Comfort Systems LS-24B2-1 User manual Electric Heater 0
16 A.O. Smith AH - 290 User manual Electric Heater 6
17 A.O. Smith AHD 290 User manual Electric Heater 7
18 A.O. Smith AHDS 290 User manual Electric Heater 0
19 A.O. Smith ST 3000 User manual Electric Heater 5
20 A.O. Smith WATER HEATERS User manual Electric Heater 13