Desa GVC65PA user manual

User manual for the device Desa GVC65PA

Device: Desa GVC65PA
Category: Electric Heater
Manufacturer: Desa
Size: 0.43 MB
Added : 5/4/2013
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Desa GVC65PA. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Desa GVC65PA.

For your convenience

If looking through the Desa GVC65PA user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Desa GVC65PA on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Desa GVC65PA to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Desa GVC65PA User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Desa GVC65PA but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Desa GVC65PA. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
VENTED PROPANE
GAS HEATERS
OWNER’S OPERATION AND INSTALLATION MANUAL
Models: GVC65PA, GVC50PA, GVC35PA
WARNING: Improper installation,
WARNING: If the information in this manual
is not followed exactly, a fire or explosion
adjustment, alteration, service, or
may result causing property damage, per-
maintenance can cause property
sonal injury, or loss of life.
damage, personal injury or loss of
FOR YOUR SAFETY
life. Refer to this manual for cor-
— Do not store or use gasoline or other
rect inst

Summary of the content on the page No. 2

SECTION PAGE CONTENTS Safety Information......................................................................... 3 Product Identification .................................................................... 5 Local Codes ................................................................................... 6 Unpacking .................................................................................... 6 Product Features ............................................................................ 6

Summary of the content on the page No. 3

SAFETY WARNINGS IMPORTANT: Read this owner’s manual carefully and completely be- INFORMATION fore trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning. DANGER Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the he

Summary of the content on the page No. 4

SAFETY WARNINGS Continued INFORMATION 7. Provide the following minimum heater clearances from combustibles (as viewed from the front of heater): Continued Front: 48 inches Back: 6 inches Top: 53 inches Right Side: 12 inches Left Side: 6 inches 8. Do not run heater • where flammable liquids or vapors are used or stored • under dusty conditions 9. Never place clothing or any flammable objects on the heater or venting system. 10. Heater and venting system surfaces are very hot during operation. Ke

Summary of the content on the page No. 5

Control PRODUCT Knob IDENTIFICATION Ignitor Button Lower Front Access Panel Figure 1 - Vented Propane Gas Heater Draft Hood Outlet for Venting System Control Valve Blower (on models equipped with blower) Figure 2 - Vented Propane Gas Heater, Rear View 5 100748

Summary of the content on the page No. 6

Install and use heater with care. Follow all local codes. In the absence of local LOCAL CODES codes, use the latest edition of the following: • National Fuel Gas Code ANSI Z223.1, also known as NFPA 54 * • National Electrical Code ANSI/NFPA 70 * • National Standard of Canada CAN1-B149 ** *Available from: American National Standards Institute, Inc., 1430 Broadway, New York, NY 10018; or National Fire Protection Association, Inc., Batterymarch Park, Quincy, MA 02269 **Available from: Standards C

Summary of the content on the page No. 7

LOCATING HEATER INSTALLING HEATER WARNING Continued Maintain the minimum clearances shown in Figure 3, below. If you can, provide greater clearances. WARNING Never install the heater • in a mobile home or a recreational vehicle. • where curtains, furniture, clothing, or other flam- mable objects are less than 48 inches from the front, 53 inches from the top, 12 inches from the right side and 6 inches from the left side and back of heater. • directly on carpeting, tile, or other combustible mat

Summary of the content on the page No. 8

VENTING HEATER INSTALLING Note: Venting/chimney materials are not supplied with heater. HEATER Continued WARNING A qualified service person must install the venting system for this heater. If venting system is not properly installed and maintained, the vent safety shut-off system will pre- vent the heater from running. Follow all local codes. WARNING This heater has a vent safety shut-off system. This system shuts off the heater gas supply if you do not vent heater properly or the venting syst

Summary of the content on the page No. 9

VENTING HEATER (continued) INSTALLING WARNING HEATER Do not vent heater in any of the following ways (see Figure 4). Continued The vertical section of vent pipe must Heater must be vented to the out- extend at least two feet above the doors. Never vent heater to another highest point of any roof within ten room or inside a building. feet. Never extend vent pipe horizontally Never extend vent pipe horizontally through a chimney or flue. You must through outside wall and terminate. con

Summary of the content on the page No. 10

VENTING HEATER (continued) INSTALLING Proper Size Vent HEATER To safely vent heater, the vent connector pipe must be the same diameter as the draft Continued hood outlet on the rear of the heater. Pipe that is too small can cause flue gas to spill from the heater. Fasten vent connector to the draft hood outlet with a sheet metal screw. Vent Types Prefabricated or Masonry All-Fuel Chimney - This is a masonry chimney or a residential-type prefabricated chimney. Only use prefabricated chimneys list

Summary of the content on the page No. 11

CONNECTING TO GAS SUPPLY INSTALLING HEATER WARNING Continued A qualified service person must connect heater to gas supply. Follow all local codes. CAUTION Never connect heater directly to the propane supply. This heater requires an external regulator (not sup- plied). Install the external regulator between the heater and propane supply. The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11

Summary of the content on the page No. 12

Installation must include a manual shutoff valve, ground joint union, plugged 1/8" INSTALLING NPT tap and a sediment trap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 7). HEATER Continued Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves. CAUTION Use pipe joint sealant that is resistant to liquid petro- leum (LP) gas. Instal

Summary of the content on the page No. 13

CHECKING GAS CONNECTIONS INSTALLING WARNING HEATER Test all gas piping and connections for leaks after install- Continued ing or servicing. Correct all leaks at once. WARNING Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once. CAUTION Make sure external regulator has been installed be- tween propane supply and heater. See guidelines under Connecting to Gas Supply, page 11. Pressure Testing

Summary of the content on the page No. 14

FRESH AIR FOR WARNING COMBUSTION This heater must have fresh air for proper operation. If not, poor fuel combustion and improper venting of flue AND gases will result. Carbon monoxide poisoning from VENTILATION backed-up flue gases could occur. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home. Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce hea

Summary of the content on the page No. 15

DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION FRESH AIR FOR Example 1: Locating Heater in Unconfined (Open) Area COMBUSTION AND NOTICE An unconfined area has a minimum air volume of 50 VENTILATION cubic feet for each 1000 BTU/Hr input rating of all Continued appliances in the area (cubic feet equals length x width x height of area). Include adjoining rooms only if there are no doors between the rooms or if you add ventila- tion grills between the rooms (see Ventilating Confined Area, page 17).

Summary of the content on the page No. 16

Draft Hood Spillage: This is a hazardous situation. Draft hood spillage re- FRESH AIR FOR leases poisonous carbon monoxide gas into your home. COMBUSTION DANGER AND Carbon monoxide poisoning may lead to death! VENTILATION If draft hood spillage occurs, check for blocked flue connectors, vent pipes, and Continued chimneys. If you find blockage, remove. Test again for spillage. If spillage still occurs or there was no blockage, you need more fresh, outside air in the house. You must provide addit

Summary of the content on the page No. 17

Example 2: Locating Heater in Confined (Closed) Area FRESH AIR FOR COMBUSTION NOTICE A confined area has an air volume of less than 50 cubic AND feet for each 1000 BTU/Hr input rating of all appliances VENTILATION in the area (cubic feet equals length x width x height of Continued area). Include adjoining rooms only if there are no doors between the rooms. If you install this heater in a confined area, you must provide additional fresh air. Ventilating Confined Area This fresh air would come fro

Summary of the content on the page No. 18

OPERATING WARNING Heater and venting system surfaces are very hot during HEATER operation. Keep children and adults away from hot sur- faces to avoid burns and clothing ignition. Carefully super- vise young children when they are in the same room as heater. Heater will remain hot for a time after shut down. Let surface cool before touching. NOTICE If operating heater for the first time, a slight odor will occur. This odor will go away after a few hours of operation. FOR YOUR SAFETY READ BEFORE

Summary of the content on the page No. 19

5. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the OPERATING floor. If you smell gas, STOP! Follow “B” in the safety information at the top of page 18. If you don’t smell gas, go to the next step. HEATER 6. Remove lower front access panel on heater. Continued 7. Turn control knob clockwise to the PILOT position. Fully depress Clockwise control knob for five seconds. Note: You may be running this heater for the first time after hooking up to gas supply. If so,

Summary of the content on the page No. 20

MANUAL LIGHTING PROCEDURE OPERATING HEATER 1. Remove lower front access panel on heater. Continued 2. Locate pilot. Pilot is attached to the front of burner. 3. Follow steps 1 through 7 under Lighting Instructions, pages 18 and 19. 4. With control knob depressed, strike match. Hold match to pilot until pilot lights. 5. Follow steps 9 through 13 under Lighting Instructions, page 19. BLOWER OPERATION (For Models with Blower) WARNING This heater has a three-prong, grounded electrical plug. This pl


Alternative user manuals
# User manual Category Download
1 Desa 000 BTU SPC-30R User manual Electric Heater 0
2 Desa 000 Btu/hr Models User manual Electric Heater 0
3 Desa 000-12 User manual Electric Heater 0
4 Desa 100 User manual Electric Heater 0
5 Desa 104504-02 User manual Electric Heater 0
6 Desa 000-15 User manual Electric Heater 0
7 Desa 000-30 User manual Electric Heater 0
8 Desa 050 BTU User manual Electric Heater 0
9 Desa 105801-09 User manual Electric Heater 0
10 Desa 105838-02 User manual Electric Heater 0
11 Desa 10 User manual Electric Heater 0
12 Desa 101811-01C.pdf User manual Electric Heater 0
13 Desa 000-24 User manual Electric Heater 0
14 Desa 104506-02 User manual Electric Heater 0
15 Desa 106040-02 User manual Electric Heater 0
16 A.O. Smith AH - 290 User manual Electric Heater 6
17 A.O. Smith AHD 290 User manual Electric Heater 7
18 A.O. Smith AHDS 290 User manual Electric Heater 0
19 A.O. Smith ST 3000 User manual Electric Heater 5
20 A.O. Smith WATER HEATERS User manual Electric Heater 13