Desa CCL3018P user manual

User manual for the device Desa CCL3018P

Device: Desa CCL3018P
Category: Electric Heater
Manufacturer: Desa
Size: 5.51 MB
Added : 11/15/2013
Number of pages: 44
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Desa CCL3018P. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Desa CCL3018P.

For your convenience

If looking through the Desa CCL3018P user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Desa CCL3018P on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Desa CCL3018P to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Desa CCL3018P User manual - Online PDF
Advertisement
« Page 1 of 44 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Desa CCL3018P but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Desa CCL3018P. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

UNVENTED (VENT-FREE) PROPANE/LP
GAS LOG HEATER
OWNER’S OPERATION AND INSTALLATION
MANUAL
For more information, visit www.desatech.com For more information, visit www.desatech.com
18", 24", and 30"
18", 24", and 30" Variable
Thermostatically-Controlled
Manually-Controlled Models
Models
CGD3018P CCL3924P
CGD3924PT CGD3930PT
CGD3924P CRL2718P
CGD3018PT CCL3018PT
CGD3930P CRL3124P
CCL3924PT CCL3930PTA
CCL3018P
(Smoky Mountain Oak Model Shown)
BILTMORE SPLIT OAK, SEASONAL OAK
AND SMOKY MOUNTAIN OAK L

Summary of the content on the page No. 2

TABLE OF CONTENTS SAFETY INFORMATION 2 TABLE OF CONTENTS SAFETY INFORMATION ............................................................ 2 OPTIONAL POSITIONING OF THERMOSTAT PRODUCT IDENTIFICATION ..................................................... 3 SENSING BULB................................................................... 27 LOCAL CODES ........................................................................... 4 REPLACEMENT PARTS ....................................................

Summary of the content on the page No. 3

SAFETY INFORMATION 3 PRODUCT IDENTIFICATION 3 SAFETY INFORMATION Continued 1. This appliance is only for use with the type of gas indicated on 14. Do not use heater if any part has been exposed to or under wa- the rating plate. This appliance is not convertible for use with ter. Immediately call a qualified service technician to inspect other gases. the room heater and to replace any part of the control system and any gas control which has been under water. 2. Do not place propane/LP supply tank

Summary of the content on the page No. 4

LOCAL CODES 4 UNPACKING PRODUCT FEATURES AIR FOR COMBUSTION AND VENTILATION Providing Adequate Ventilation LOCAL CODES AIR FOR COMBUSTION AND Install and use heater with care. Follow all local codes. In the absence VENTILATION of local codes, use the latest edition of The National Fuel Gas Code, ANSI Z223.1/NFPA 54*. WARNING: This heater shall not be installed in a *Available from: confined space or unusually tight construction unless American National Standards Institute, Inc. provisions are p

Summary of the content on the page No. 5

AIR FOR COMBUSTION AND VENTILATION 5 Providing Adequate Ventilation (Cont.) 5 Determining Fresh-Air Flow for Heater Location AIR FOR COMBUSTION AND VENTILATION Continued c. caulking or sealants are applied to areas such as 3. Add the Btu/Hr of all fuel burning appliances in the space. joints around window and door frames, between sole Vent-free heater _____________ Btu/Hr plates and floors, between wall-ceiling joints, between Gas water heater* _____________ Btu/Hr wall panels, at penetrations f

Summary of the content on the page No. 6

AIR FOR COMBUSTION AND VENTILATION Ventilation Air 6 AIR FOR COMBUSTION AND VENTILATION Continued VENTILATION AIR 12" Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. Ventilation When ventilating to an adjoining unconfined space, you must Ventilation Grills Grills provide two permanent openings: one within 12" of the ceiling and Into Adjoining Room, Into Adjoining Or Option 2 one within 12" of the floor on the wall connecting the two spaces Ro

Summary of the content on the page No. 7

INSTALLATION 7 Check Gas Type 7 Installation and Clearances for Vent-Free Operation INSTALLATION NOTICE: This heater is intended for use as supple- CAUTION: This heater creates warm air currents. mental heat. Use this heater along with your primary These currents move heat to wall surfaces next to heating system. Do not install this heater as your heater. Installing heater next to vinyl or cloth wall primary heat source. If you have a central heating coverings or operating heater where impuriti

Summary of the content on the page No. 8

INSTALLATION Installation and Clearances for Vent-Free Operation (Cont.) 8 INSTALLATION Continued If Using Mantel Minimum Clearances For Side Combustible Mate- rial, Side Wall, and Ceiling You must have noncombustible material(s) above the fireplace opening. Noncombustible materials (such as slate, marble, tile, etc.) A. Clearances from the side of the fireplace cabinet to any com- bustible material and wall should follow diagram in Figure 5. must be at least 1/2 inch thick. With sheet metal, yo

Summary of the content on the page No. 9

INSTALLATION 9 Mantel Clearances 9 Floor Clearances INSTALLATION Continued Mantel Shelf MANTEL CLEARANCES 12" Underside of 10" Mantel Shelf In addition to meeting noncombustible material clearances, you 8" must also meet required clearances between fireplace opening and 6" mantel shelf. If you do not meet the clearances in Figure 7, you will 1 2 /2" All minimum need a hood. distances are in inches Minimum Non- Determining Minimum Mantel Clearance Combustible Log Set Material All Models 8" 12"

Summary of the content on the page No. 10

INSTALLATION Installing Damper Clamp Accessory for Vented Operation 10 Installing Heater Base Assembly INSTALLATION Continued INSTALLING HEATER BASE ASSEMBLY INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION CAUTION: Do not remove the data plates attached Note: When used as a vented heater, appliance must be installed to the heater base assembly. The data plates contain only in a solid-fuel burning fireplace with a working flue and important warranty and safety information. constructed of

Summary of the content on the page No. 11

INSTALLATION 11 Installing Heater Base Assembly (Cont.) 11 Connecting to Gas Supply INSTALLATION Continued 7. Mark screw locations through holes in mounting brackets (see CONNECTING TO GAS SUPPLY Figure 13 and 14). If installing in a brick-bottom fireplace, mark screw locations in mortar joint of bricks. WARNING: This appliance requires a 1/2" NPT 8. Remove heater base from fireplace. (National Pipe Thread) inlet connection to the pres- 9. Drill holes at marked locations using 3/16" drill bit.

Summary of the content on the page No. 12

INSTALLATION Connecting to Gas Supply (Cont.) 12 Checking Gas Connections INSTALLATION Continued WARNING: Use pipe joint sealant that is resistant CAUTION: Use only new, black iron or steel pipe. to liquid petroleum (LP) gas. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diam- We recommend that you install a sediment trap in supply line as eter or greater to allow proper gas volume to heater. If shown in Figure 16. Locate sediment trap

Summary of the content on the page No. 13

INSTALLATION 13 Checking Gas Connections (Cont.) 13 Installing Logs INSTALLATION Continued Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) INSTALLING LOGS 1. Close equipment shutoff valve (see Figure 17). CAUTION: After installation and periodically there- 2. Pressurize supply piping system by either using compressed after, check to ensure that no flame comes in contact air or opening propane/LP supply tank valve. with any log. With the heater set to high, check to see 3. Check all join

Summary of the content on the page No. 14

3 INSTALLATION Installing Logs (Cont.) 14 INSTALLATION Continued Notches 2. Place the base of the middle log (#2) in the U-shaped slots of the Crossover Log (#4) grate base in front of the back log. The cutout on the right of the middle log should fit over the burner (see Figure 20). Make sure the front of the middle log is resting on the tabs of the grate base and the cutout area is centered over the burner “U” bend. 3. Locate the recesses on the back of the front log (#3). Fit these recesses b

Summary of the content on the page No. 15

INSTALLATION 15 Installing Logs (Cont.) 15 INSTALLATION Continued 2. Locate pins on the bottom of back log (#2). Slide these pins into 5. With knot to right side, place smaller log piece (#5) over the the holes in the grate base behind the burner (see Figure 24). pin on the left side of the middle log. The smaller log will rest on front log against the "knot" on the left. See Figure 27. 3. Place crossover log (#3) onto the pin (right) on middle log (#1) and into the recess of the back log (#2).

Summary of the content on the page No. 16

INSTALLATION Installing Logs (Cont.) 16 INSTALLATION Continued Dual Burner Biltmore Split Oak Models WARNING: Failure to position the parts in accor- Middle Log (#2) dance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. CAUTION: After installation and periodically there- after, check to ensure that no flame comes in contact Burner with any log. With the heater set to HI, check to see if flames contact any

Summary of the content on the page No. 17

6 7 INSTALLATION 17 Installing Logs (Cont.) 17 INSTALLATION Continued 5. For CCL3924PT and CCL3930PTA Only: Locate pin and hole on the bottom of crossover log (#5). Slide the pin into the hole located in crossover log (#4). Slide the hole onto the pin on front log (#1). See Figure 32. For CCL3018P and CCL3018PT Only: Locate holes on the bot- tom of crossover log (#5). Slide the holes over the left pins on middle log (#2) and front log (#1). See Figure 33. 6. Locate holes on the bottom of crossov

Summary of the content on the page No. 18

INSTALLATION Installing Logs (Cont.) 18 INSTALLATION Continued Single Burner Seasonal Oak Models Front Log WARNING: Failure to position the parts in accor- dance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. The Seasonal Oak Log Set is a reversible log set. This means that the two bottom logs may be turned to face either direction. The top log, however, must remain in the same position. Do not modify log

Summary of the content on the page No. 19

OPERATING HEATER (Manually Controlled Models) 19 For Your Safety Read Before Lighting 19 Lighting Instructions OPERATING HEATER Manually-Controlled Models Note: Home owners generally prefer to operate their heater FOR YOUR SAFETY with the chimney damper closed. This will put all the heat into READ BEFORE LIGHTING the room. However, there may be times you will desire the full flames of the HI heat setting but will find the heat output WARNING: If you do not follow these instructions excessive. Y

Summary of the content on the page No. 20

OPERATING HEATER (Manually Controlled Models Lighting Instructions (Cont.) 20 Variable Control Operation To Turn Off Gas To Appliance Manual Lighting Procedure OPERATING HEATER (Thermostatically-Controlled Models) For Your Safety Read Before Lighting OPERATING HEATER Continued 6. With control knob pressed in, press and release ignitor but- MANUAL LIGHTING PROCEDURE ton. This will light pilot. The pilot is attached to the burner. If needed, keep pressing ignitor button until pilot lights. 1. Fol


Alternative user manuals
# User manual Category Download
1 Desa 000 BTU SPC-30R User manual Electric Heater 0
2 Desa 000 Btu/hr Models User manual Electric Heater 0
3 Desa 000-12 User manual Electric Heater 0
4 Desa 100 User manual Electric Heater 0
5 Desa 104504-02 User manual Electric Heater 0
6 Desa 000-15 User manual Electric Heater 0
7 Desa 000-30 User manual Electric Heater 0
8 Desa 050 BTU User manual Electric Heater 0
9 Desa 105801-09 User manual Electric Heater 0
10 Desa 105838-02 User manual Electric Heater 0
11 Desa 10 User manual Electric Heater 0
12 Desa 101811-01C.pdf User manual Electric Heater 0
13 Desa 000-24 User manual Electric Heater 0
14 Desa 104506-02 User manual Electric Heater 0
15 Desa 106040-02 User manual Electric Heater 0
16 A.O. Smith AH - 290 User manual Electric Heater 6
17 A.O. Smith AHD 290 User manual Electric Heater 7
18 A.O. Smith AHDS 290 User manual Electric Heater 0
19 A.O. Smith ST 3000 User manual Electric Heater 5
20 A.O. Smith WATER HEATERS User manual Electric Heater 13