Desa CBT30PT user manual

User manual for the device Desa CBT30PT

Device: Desa CBT30PT
Category: Electric Heater
Manufacturer: Desa
Size: 1.59 MB
Added : 11/15/2013
Number of pages: 32
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Desa CBT30PT. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Desa CBT30PT.

For your convenience

If looking through the Desa CBT30PT user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Desa CBT30PT on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Desa CBT30PT to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Desa CBT30PT User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Desa CBT30PT but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Desa CBT30PT. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

UNVENTED (VENT-FREE) BLUE FLAME GAS HEATER
SAFETY INFORMATION AND INSTALLATION MANUAL
CBN20, CBP20, SBN20, SBP20, CBN20T, CBP20T,
CBN30T, CBP30T, CBT20NT, CBT20PT, CBT30NT, CBT30PT,
CBN20TK, CBP20TK
WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing
property damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMEL

Summary of the content on the page No. 2

WARNING: Improper installation, adjustment, altera- tion, service, or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi- tional information consult a qualified installer, service agency, or the gas supplier. WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provi- sions for adequate combustion and ventilation air must be provided. Refer to

Summary of the content on the page No. 3

SAFETY INFORMATION Due to high temperatures, the appliance should be located out IMPORTANT: Read this owner’s of traffic and away from furniture manual carefully and completely and draperies. before trying to assemble, op- erate, or service this heater. Do not place clothing or other Improper use of this heater can flammable material on or near cause serious injury or death the appliance. Never place any from burns, fire, explosion, objects on the heater. electrical shock, and carbon

Summary of the content on the page No. 4

SAFETY INFORMATION UNPACKING Continued 1. Remove heater from carton. 2. Remove all protective packaging applied to 4. This heater shall not be installed in a bedroom heater for shipment. or bathroom. 3. Check heater for any shipping damage. If 5. This heater needs fresh, outside air ventilation heater is damaged, promptly return to dealer to run properly. This heater has an Oxygen where you bought heater. Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if PRO

Summary of the content on the page No. 5

Unusually tight construction is defined as AIR FOR COMBUSTION construction where: AND VENTILATION a. walls and ceilings exposed to the out- side atmosphere have a continuous WARNING: This heater shall water vapor retarder with a rating of not be installed in a confined -11 2 one perm (6x10 kg per pa-sec-m ) or space or unusually tight con- less with openings gasketed or sealed struction unless provisions are and b. weather stripping has been added on provided for adequate combus- openabl

Summary of the content on the page No. 6

4. Compare the maximum Btu/Hr the space can AIR FOR COMBUSTION support with the actual amount of Btu/Hr used. AND VENTILATION _______________Btu/Hr (maximum the space Continued can support) _______________Btu/Hr (actual amount of DETERMINING FRESH-AIR FLOW Btu/Hr used) FOR HEATER LOCATION Example: Determining if You Have a Confined or 51,200 Btu/Hr (maximum the space can support) Unconfined Space 60,000 Btu/Hr (actual amount of Btu/Hr used) Use this work sheet to determine if yo

Summary of the content on the page No. 7

AIR FOR COMBUSTION Ventilated Outlet Attic AND VENTILATION Air Continued Outlet Air To Attic VENTILATION AIR Ventilation Air From Inside Building To This fresh air would come from an adjoining un- Crawl Space confined space. When ventilating to an adjoining Inlet Air unconfined space, you must provide two perma- Ventilated nent openings: one within 12” of the ceiling and Inlet Air Crawl Space one within 12” of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). Y

Summary of the content on the page No. 8

INSTALLATION Continued WARNING: Never install the heater INSTALLATION ITEMS • in a bedroom or bathroom Before installing heater, make sure you have the • in a recreational vehicle items listed below. • where curtains, furniture, • for propane/LP gas, external regulator (supplied clothing, or other flammable by installer) objects are less than 36 inches • piping (check local codes) from the front, top, or sides of • sealant (resistant to propane/LP gas) • equipment shutoff valve * the heat

Summary of the content on the page No. 9

INSTALLATION Continued THERMOSTAT SENSING BULB The thermostat sensing bulb is below the heater. 1. Place clamp on thermostat sensing bulb as shown in Figure 5. Clamp is provided in hardware package. 2. Snap clamp into upper mounting hole as shown in Figure 5. Mounting hole is located on lower left edge on back of heater. Make sure the thermostat sensing bulb is pointing up. Figure 7 - Removing Front Panel Of Thermostat Heater Sensing Bulb Methods For Attaching Mounting Bracket To Wall C

Summary of the content on the page No. 10

Attaching To Wall Anchor Method INSTALLATION For attaching mounting bracket to hollow walls Continued (wall areas between studs) or solid walls (concrete 2. Mark screw locations on wall (see Figure 8). or masonry) Note: Only mark last hole on each end of 1. Drill holes at marked locations using 5/16" mounting bracket. Insert mounting screws drill bit. For solid walls (concrete or masonry), through these holes only. drill at least 1" deep. 3. Remove tape and mounting bracket from 2. Fold

Summary of the content on the page No. 11

MOUNTING HEATER TO FLOOR INSTALLATION (OPTIONAL) Continued Mounting Base Feet to Heater Installing Bottom Mounting Screws 1. Lay heater cabinet on its back on a table 1. Locate two bottom mounting holes. These with the heater bottom overhanging the table holes are near bottom on back panel of heater edge. (see Figure 12). 2. Align holes in base foot with mounting holes 2. Mark screw locations on wall. on bottom of cabinet (see Figure 13). 3. Remove heater from mounting bracket. 3. Secure

Summary of the content on the page No. 12

INSTALLATION Propane/LP Continued Supply Tank External CONNECTING TO GAS SUPPLY Regulator WARNING: This appliance requires a 3/8" NPT (National Pipe Thread) inlet connection to Vent the pressure regulator. Pointing Down WARNING: A qualified ser- vice person must connect heater Figure 14 - External Regulator With to gas supply. Follow all local Vent Pointing Down codes. Typical Inlet Pipe Diameters 20,000 Btu/Hr Models - 3/8" or greater WARNING: For natural 30,000 Btu/Hr Models - 1/2

Summary of the content on the page No. 13

INSTALLATION Continued CAUTION: For propane/LP gas, make sure external regula- Note: Burner bracket tor has been installed between not shown for clarity Heater propane/LP supply and heater. Pressure Cabinet See guidelines under Connect- Regulator ing to Gas Supply, page 12. 3/8" NPT Pipe Nipple PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Tee Joint Test Pressures In Excess Of 1/2 PSIG Ground Joint Reducer (3.5 kPa) Union Bushing to 1. Disconnect appliance with its appliance main 1/8" NP

Summary of the content on the page No. 14

INSTALLATION OPERATING HEATER Continued FOR YOUR SAFETY READ BEFORE LIGHTING PRESSURE TESTING HEATER GAS CONNECTIONS 1. Open equipment shutoff valve (see Figure 16, WARNING: If you do not fol- page 13). low these instructions exactly, 2. For natural gas open main gas valve located a fire or explosion may result on or near gas meter. For propane/LP gas open causing property damage, per- propane/LP supply tank valve. sonal injury or loss of life. 3. Make sure control knob of heater is in t

Summary of the content on the page No. 15

Thermocouple OPERATING HEATER Continued Ignitor Electrode 5. Turn control knob counterclockwise Pilot Burner to the PILOT position. Press in control knob for five (5) seconds (see Figure 19). Note: You may be running this heater for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system. • If control knob does not pop up when released, contact a qualified service person Fig

Summary of the content on the page No. 16

BURNER FLAME PATTERN OPERATING HEATER Continued WARNING: If yellow tipping MANUAL LIGHTING occurs, your heater could pro- PROCEDURE duce increased levels of carbon 1. Remove front panel (see Figure 7, page 9). monoxide. 2. Follow steps 1 through 5 under Lighting Instructions, page 14. NOTICE: Do not mistake orange 3. With control knob pressed in, strike match. flames with yellow tipping. Dirt Hold match to pilot until pilot lights. or other fine particles enter the 4. Keep control knob p

Summary of the content on the page No. 17

3. Blow air through the ports/slots and holes in CLEANING AND the burner. MAINTENANCE 4. Never insert objects into the pilot tube. Clean the pilot assembly also. A yellow tip on the WARNING: Turn off heater pilot flame indicates dust and dirt in the pilot as- and let cool before cleaning. sembly. There is a small pilot air inlet about two inches from where the pilot flame comes out of the pilot assembly (see Figure 25). With the unit CAUTION: You must keep off, lightly blow air through t

Summary of the content on the page No. 18

SPECIFICATIONS CBN20/CBN20T CBN30T CBT20NT CBT30NT SBN20 Btu (Variable) 10,000/20,000 15,000/30,000 10,000/20,000 15,000/30,000 Type Gas --------------------------------Natural Only--------------------------------- Ignition Piezo Piezo Electronic Electronic Pressure Regulator Setting 3" W.C. 3" W.C. 3" W.C. 3"W.C. Inlet Gas Pressure (in. of water) Maximum 10.5" 10.5" 10.5" 10.5" Minimum 4" 4" 4" 4" Dimensions, Inches (H x W x D) Heater (With knobs & grill) 26.25x18.25x7 26.25x25.75x7 26.

Summary of the content on the page No. 19

TROUBLESHOOTING WARNING: Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignitor button is pressed, 1. Ignitor electrode positioned 1. Replace pilot assembly there is no spark at ODS/pilot wrong 2. Ignito

Summary of the content on the page No. 20

TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY ODS/pilot lights but flame 1. Control knob not fully pressed in 1. Press in control knob fully goes out when control knob is 2. Control knob not pressed in 2. After ODS/pilot lights, keep con- released long enough trol knob pressed in 30 seconds 3. Safety interlock system has 3. Wait one minute for safety in- been triggered terlock system to reset. Repeat ignition operation 4. Equipment shutoff valve not 4. Fully open equipment sh


Alternative user manuals
# User manual Category Download
1 Desa 000 BTU SPC-30R User manual Electric Heater 0
2 Desa 000 Btu/hr Models User manual Electric Heater 0
3 Desa 000-12 User manual Electric Heater 0
4 Desa 100 User manual Electric Heater 0
5 Desa 104504-02 User manual Electric Heater 0
6 Desa 000-15 User manual Electric Heater 0
7 Desa 000-30 User manual Electric Heater 0
8 Desa 050 BTU User manual Electric Heater 0
9 Desa 105801-09 User manual Electric Heater 0
10 Desa 105838-02 User manual Electric Heater 0
11 Desa 10 User manual Electric Heater 0
12 Desa 101811-01C.pdf User manual Electric Heater 0
13 Desa 000-24 User manual Electric Heater 0
14 Desa 104506-02 User manual Electric Heater 0
15 Desa 106040-02 User manual Electric Heater 0
16 A.O. Smith AH - 290 User manual Electric Heater 6
17 A.O. Smith AHD 290 User manual Electric Heater 7
18 A.O. Smith AHDS 290 User manual Electric Heater 0
19 A.O. Smith ST 3000 User manual Electric Heater 5
20 A.O. Smith WATER HEATERS User manual Electric Heater 13