Dayton 3VH37 user manual

User manual for the device Dayton 3VH37

Device: Dayton 3VH37
Category: Electric Heater
Manufacturer: Dayton
Size: 3.72 MB
Added : 8/29/2013
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Dayton 3VH37. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Dayton 3VH37.

For your convenience

If looking through the Dayton 3VH37 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Dayton 3VH37 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Dayton 3VH37 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Dayton 3VH37 User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Dayton 3VH37 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Dayton 3VH37. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

3E132 thru 3E134, 3E460 thru 3E462,
Installation, Operation, Maintenance and Parts Manual
5VD57 thru 5VD66, 3VH34 thru 3VH37

Please read and save these instructions. This heater must be installed and serviced by trained gas installation and service
personnel only! Read carefully before attempting to assemble, install, operate or maintain the product described. Protect
yourself and others by observing all safety information. Failure to comply with instructions

Summary of the content on the page No. 2

3E132 thru 3E134, 3E460 thru 3E462, Dayton Installation, Operation, Maintenance and Parts Manual 5VD57 thru 5VD66, 3VH34 thru 3VH37 ® Dayton High Intensity Heaters 1.0 Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Safety Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Applications . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 3

! Dayton Installation, Operation, Maintenance and Parts Manual Models 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 1.0 Safety ! WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, E serious injury or death. Read and understand, the installation, operating and maintenance N instructions thoroughly before installing or servicing this equipment. Only trained, qualifi

Summary of the content on the page No. 4

! 3E132 thru 3E134, 3E460 thru 3E462, Dayton Installation, Operation, Maintenance and Parts Manual 5VD57 thru 5VD66, 3VH34 thru 3VH37 ® Dayton High Intensity Heaters Clearance to Combustibles ! WARNING ! CAUTION Signs shall be posted specifying the Improperly connected gas lines may result maximum permissible stacking height in in serious injury and death, explosion, E order to maintain clearances to poisonous fumes, toxic gases, N combustibles. asphyxiation. Connect gas lines in G accor

Summary of the content on the page No. 5

Dayton Installation, Operation, Maintenance and Parts Manual Models 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 Chart 1.1 - Clearance to Combustibles in Inches (see Figure 1.1) Model No. BTU/H Gas Type Voltage Sides Back Top Below/Front 3E132 30,000 Natural 120V 30 18 28 72 3E460 30,000 Propane 120V 30 18 28 72 5VD61 30,000 Natural 24V 30 18 28 72 E 5VD62 30,000 Propane 24V 30 18 28 72 N G 3E133 60,000 Natural 120V 3

Summary of the content on the page No. 6

3E132 thru 3E134, 3E460 thru 3E462, Dayton Installation, Operation, Maintenance and Parts Manual 5VD57 thru 5VD66, 3VH34 thru 3VH37 ® Dayton High Intensity Heaters Standards, Certifications and Governmental Regulations The installation of this heater must comply with all applicable local, state and national specifications, regulations and building codes (contact the local building inspector and/or fire marshall for guidance) before installing the heater system. In the absence of local codes, t

Summary of the content on the page No. 7

Dayton Dayton Installation, Operation, Maintenance and Parts Manual Models 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 Figure 1.2 - Heater Dimensions DIM. “C” E N G L I S H DIM. “A” DIM. “B” SIDE VIEW FRONT/REAR Chart 1.2 - Heater Dimensions HEATER WIDTH HEATER DEPTH RAYHEAD(S) WIDTH HANGING MODEL BTU/H DIM “A” DIM “B” DIM “C” WEIGHT ” ” 12 3/4 14 1/4 5” 18 lbs. 30,000 ” ” ” 60,000 19 1/8 15 1/4 11 1/2 27 lbs. ” ” 2

Summary of the content on the page No. 8

3E132 thru 3E134, 3E460 thru 3E462, Dayton Installation, Operation, Maintenance and Parts Manual 5VD57 thru 5VD66, 3VH34 thru 3VH37 ® Dayton High Intensity Heaters Safety Signs and Labels It is important to provide warnings to alert individuals to Safety warning labels must be maintained on the potential hazards and safety actions. ANSI Z83.19a and the infra-red heater. Illustrations of the safety labels, National Fuel Gas Code require you to post a sign “specifying and their locations, ar

Summary of the content on the page No. 9

! Dayton Installation, Operation, Maintenance and Parts Manual Models 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 2.0 Installation ! ! CAUTION WARNING This heater cannot be used in a building with an Read and understand, the uninsulated roof or condensation problems can occur. E installation, operating and N maintenance instructions thoroughly G before installing or servicing this Factory recommended mounting he

Summary of the content on the page No. 10

3E132 thru 3E134, 3E460 thru 3E462, Dayton Installation, Operation, Maintenance and Parts Manual 5VD57 thru 5VD66, 3VH34 thru 3VH37 ® Dayton High Intensity Heaters Chart 2.1 - Recommended Mounting Heights and Distances for “Total Area” Heating Mounting Heights Dim. A Distance Distance Distance Between Between Between 30º Angle 30º Angle Heaters Heater Rows Heater Parabolic Standard BTU/H Input Reflector (ft.) Dim. B (ft.) Dim. C (ft.) and Wall (ft.) Reflector (ft.) E 30,000 12-14 12-15 8-30 1

Summary of the content on the page No. 11

Dayton Installation, Operation, Maintenance and Parts Manual Models 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 Chart 2.2 - Recommended Mounting Heights and Distances for “Spot” Heater Location E N G L I 10’ 12’ 14’ 16’ 18’ 20’ S Cold/Drafty 10’ x 10’ 100 9’ 4’ 10’ H 30,000 Average 12’ x 12’ 144 10’ 12’ 5’ 12’ BTU/H Protected/Insul. 14’ x 14’ 196 12’ 14’ 6’ 14’ Cold/Drafty 16’ x16’ 256 12’ 14’ 6’ 16’ 60,000 Average 1

Summary of the content on the page No. 12

Dayton Dayton ! ! 3E132 thru 3E134, 3E460 thru 3E462, Dayton Installation, Operation, Maintenance and Parts Manual 5VD57 thru 5VD66, 3VH34 thru 3VH37 ® Dayton High Intensity Heaters Heater Mounting ! ! WARNING ! WARNING Failure to maintain minimum clearance Improper suspension of the infra-red to combustibles may result in fire and/ heater may result in collapse and being E or explosion, property damage, serious crushed. Always suspend from a N injury or death. Always maintain permanent p

Summary of the content on the page No. 13

Dayton Dayton Dayton Installation, Operation, Maintenance and Parts Manual Models 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 Figure 2.4 Heater Orientation Manifold control box must be located towards the lower end of the heater (towards the floor). E N G L Spark electrode must be I in lower right corner. S H Angled at Mount Heater Level 20˚ - 35˚ from horizontal FRONT VIEW SIDE VIEW Figure 2.5 • Gas Connection

Summary of the content on the page No. 14

Dayton ! 3E132 thru 3E134, 3E460 thru 3E462, Dayton Installation, Operation, Maintenance and Parts Manual 5VD57 thru 5VD66, 3VH34 thru 3VH37 ® Dayton High Intensity Heaters Ventilation ! ! CAUTION WARNING Improper ventilaton may result in Ventilate enclosed spaces and buildings property damamge, health problems, according to national, state, provincial E carbon monoxide poisoning, injury or and local codes. Failure to provide N death. adequate ventilation may result in G equipment malfu

Summary of the content on the page No. 15

! Dayton Installation, Operation, Maintenance and Parts Manual Models 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 Gas Supply Important! Before connecting the gas supply to the ! WARNING infra-red heater(s): • Check that the gas piping and service has the capacity to handle the load of all heaters being E installed, as well as any other gas appliances being N connected to the supply line. G Improperly connected ga

Summary of the content on the page No. 16

! 3E132 thru 3E134, 3E460 thru 3E462, Dayton Installation, Operation, Maintenance and Parts Manual 5VD57 thru 5VD66, 3VH34 thru 3VH37 ® Dayton High Intensity Heaters ! To connect the gas: This heater must be installed and serviced by trained gas ! installation and service personnel only. WARNING Failure to install, operate or service this The installation of this heater must conform with local appliance in the approved manner may building codes or, in the absence of such codes, the E resul

Summary of the content on the page No. 17

Dayton Installation, Operation, Maintenance and Parts Manual Models 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 Electrical Control systems are initiated by either 120 VAC or ! WARNING 24 VAC. The 120 VAC systems can be used directly from a 120 VAC line. On 24 VAC systems, transformers Electric Shock Hazard. must be used to supply power of sufficient VA rating for Field wiring to the heater must be single or mul

Summary of the content on the page No. 18

3E132 thru 3E134, 3E460 thru 3E462, Dayton Installation, Operation, Maintenance and Parts Manual 5VD57 thru 5VD66, 3VH34 thru 3VH37 ® Dayton High Intensity Heaters Wiring Diagrams Figure 2.9 - 24 V Schematic (5VD57 thru 5VD66) • Direct Spark Ignition E N • VA Draw: 12 G L • Amps: .48 I • Potted Circuit S Board H (sold separately) Figure 2.10 - 120 V Schematic (3E132 thru 3E134, 3E460 thru 3E462, 3VH34 thru 3VH37) • Direct Spark Ignition • VA Draw: 12 • Amps: .10 • Potted Circuit Board

Summary of the content on the page No. 19

! Dayton Installation, Operation, Maintenance and Parts Manual Models 3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37 3.0 Operation Upon satisfactory completion of the electrical supply ! WARNING and purging of the gas supply line to the heater(s), follow the lighting instructions on the heater’s rating Do not atempt to ignite heater by hand. label to put the heater into operation. Failure to comply could result in

Summary of the content on the page No. 20

! 3E132 thru 3E134, 3E460 thru 3E462, Dayton Installation, Operation, Maintenance and Parts Manual 5VD57 thru 5VD66, 3VH34 thru 3VH37 ® Dayton High Intensity Heaters 4.0 Maintenance ! WARNING It is recommended that the following become a standard yearly procedure to obtain maximum operating Use protective glasses when cleaning efficiency and trouble free operation. the heater. E During long periods of non-usage, remove or cover N heater with a polyethylene bag and shut off gas supply. G Di


Alternative user manuals
# User manual Category Download
1 Dayton 2E510C User manual Electric Heater 11
2 Dayton 2E510E User manual Electric Heater 1
3 Dayton 2E511B User manual Electric Heater 5
4 Dayton 2E510A User manual Electric Heater 2
5 Dayton 2E511D User manual Electric Heater 3
6 Dayton 1RVT8 User manual Electric Heater 0
7 Dayton 2E511E User manual Electric Heater 0
8 Dayton 2E511C User manual Electric Heater 0
9 Dayton 2E511A User manual Electric Heater 0
10 Dayton 3.00E+219 User manual Electric Heater 2
11 Dayton 3.00E+134 User manual Electric Heater 1
12 Dayton 3.00E+132 User manual Electric Heater 0
13 Dayton 3E218A User manual Electric Heater 1
14 Dayton 3E218B User manual Electric Heater 1
15 Dayton 3E219D User manual Electric Heater 2
16 A.O. Smith AH - 290 User manual Electric Heater 6
17 A.O. Smith AHD 290 User manual Electric Heater 7
18 A.O. Smith AHDS 290 User manual Electric Heater 0
19 A.O. Smith ST 3000 User manual Electric Heater 5
20 A.O. Smith WATER HEATERS User manual Electric Heater 13