White Rodgers 37-7248A user manual

User manual for the device White Rodgers 37-7248A

Device: White Rodgers 37-7248A
Category: Thermostat
Manufacturer: White Rodgers
Size: 3.56 MB
Added : 6/3/2013
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for White Rodgers 37-7248A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with White Rodgers 37-7248A.

For your convenience

If looking through the White Rodgers 37-7248A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual White Rodgers 37-7248A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual White Rodgers 37-7248A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
White Rodgers 37-7248A User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual White Rodgers 37-7248A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to White Rodgers 37-7248A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Blue Single 1/1 Stage Thermostat with
Automatic Heat/Cool Changeover Option
Single Stage or Heat Pump
Installation and Operating Instructions for Model:
Save these instructions for future use!
Model Programming Choices
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING THIS
1F80-0471 5/2 Day 5/1/1 Day Non-Programmable
CONTROL COULD CAUSE PERSONAL INJURY AND/OR
1F86-0471 Non-Programmable
PROPERTY DAMAGE.
APPLICATIONS
1F80-0471 Thermostat
THERMOSTAT APPLI

Summary of the content on the page No. 2

INSTALLATION Batteries WARNING ! 2 "AA" alkaline batteries are included in the thermostat. To in- stall the batteries, pull the battery door as shown by the arrow Thermostat installation and all components of the and lift open. Using the polarity indicated inside the battery control system shall conform to Class II circuits per door, insert the batteries. To close the battery door, swing the the NEC code. door down while pulling in the direction of arrow. Once fully down, snap the door ba

Summary of the content on the page No. 3

THERMOSTAT QUICK REFERENCE Figure 3 – Home Screen Display Home Screen Description Room Time Temperature Setting Day of Week Temperature Displays the power level of the 2 "AA" batteries: indicates good power level. Temperature Up/Down indicates batteries at about half power. “Change ” indicates batteries are low and should be HOLD Button replaced with 2 new premium brand “AA” Alkaline batteries. SYSTEM Indicator SYSTEM FAN Button Indicator FAN MENU/SCHEDULE/RUN Button Button

Summary of the content on the page No. 4

INSTALLER/CONFIGURATION MENU To enter the Configuration Menu, SYSTEM must be set to HEAT, COOL, Em or AUTO. Press the Menu button for at least 5 seconds. The display will show item #1 in the table below. Press Menu button to advance to the next menu item. Press or to change an item option. Shaded items are not available on 1F86. INSTALLER/CONFIGURATION MENU Menu Displayed Press or to Screen SS HP Comments (Factory Default) select from listed options Number 01   (OFF) Lk L Sele

Summary of the content on the page No. 5

INSTALLER/CONFIGURATION MENU 4) Program Options 1F80 only – This control can be configured 11) Select Compressor Lockout CL OFF or ON – Selecting for 5/2 day or 5/1/1 day programming or non-programming CL ON will cause the thermostat to wait 5 minutes between mode. The default setting is P2, indicating 5/2 day program- cooling cycles. This is intended to help protect the compres- ming. The programs per week can be toggled to P3 or P0 sor from short cycling. Some newer compressors already b

Summary of the content on the page No. 6

OPERATING YOUR THERMOSTAT IMPORTANT! Choose the Fan Setting (Auto or On) Manual Operation (Bypassing the Program) Set the FAN Switch to Auto or On. Programmable Thermostats Fan Auto is the most commonly selected setting and runs the Press or and the HOLD button and adjust the tem- fan only when the heating or cooling system is on. perature wherever you like. This will override the program. The Fan On runs the fan continuously for increased air circulation HOLD feature bypasses the program and

Summary of the content on the page No. 7

PROGRAMMING (For Programmable Model Only) Energy Saving Factory Pre-Program The 1F80-0471 thermostats are programmed with the energy saving settings shown in the table below for all days of the week. If this program suits your needs, simply set the thermostat clock and press the RUN button. The table below shows the factory set heating and cooling schedule for all days of the week. Wake Up Leave For Work Return Home Go To Bed (Period 1) (Period 2) (Period 3) (Period 4) Heating 6:00 AM 70°F 8:0

Summary of the content on the page No. 8

TROUBLESHOOTING Reset Operation Note: When thermostat is reset, installer configuration menu settings and programming will reset to factory settings. If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, you can reset the thermostat by removing the wires from terminals R and C (do not short them together) and removing batteries for 2 minutes. After resetting the thermostat, replace the wires and batteries. If the thermostat has been reset and

Summary of the content on the page No. 9

Termostato Blue Single 1/1 Stage con opción de conmutación calor/frío automática Una sola etapa o bomba de calor Instrucciones de instalación y uso para el modelo: ¡Conserve estas instrucciones para consultarlas en cualquier momento! Modelo Opciones de programación EL NO LEER Y SEGUIR CON CUIDADO TODAS LAS INSTRUCCIONES ANTES DE INSTALAR O UTILI- 1F80-0471 5/2 días 5/1/1 días No programable ZAR ESTE CONTROL PODRÍA CAUSAR LESIONES 1F86-0471 No programable PERSONALES Y/O DAÑOS MATERIALE

Summary of the content on the page No. 10

INSTALACIÓN abajo, vuelva a engancharla en su lugar. Para cambiar las pilas, ¡ADVERTENCIA! ! coloque el sistema en OFF y siga las instrucciones anteriores. La instalación del termostato y de todos los componentes del Figura 1 – Puerta del compartimiento de las pilas abierta sistema de control debe ajustarse a las normas del código NEC para los circuitos Clase II. pilas alcalinas “AA” Retire el termostato viejo Un termostato de calor/frío estándar consta de tres partes básicas: 1. La cubierta

Summary of the content on the page No. 11

GUÍA DE REFERENCIA RÁPIDA DEL TERMOSTATO Figura 3 – Pantalla principal Descripción de la pantalla principal Temperatura Hora ambiente Temperatura Día de la semana de ajuste Muestra el nivel de carga de las 2 pilas "AA": indica buen nivel de carga. indica que a las pilas les queda Subir/Bajar temperatura aproximadamente la mitad de la carga. “Change ” (Cambiar ) indica que la carga de las pilas es Botón HOLD baja y que deben cambiarse por 2 pilas alcalinas “AA”

Summary of the content on the page No. 12

MENÚ INSTALADOR/DE CONFIGURACIÓN Con el termostato en Heat, Cool o Auto, en operación normal, presione el botón Menu durante 5 segundos como mínimo. La pantalla mostrará la opción 1 tal como se describe en la siguiente tabla. Presione Menu para pasar a la siguiente opción del menu. Presione o para cambiar la opción. Los elementos sombreados no están disponibles en el modelo 1F86. INSTALLER/CONFIGURATION MENU Número de Presione o para Pantalla la Pantalla Observaciones SS HP selecc

Summary of the content on the page No. 13

MENÚ INSTALADOR/DE CONFIGURACIÓN 4) Opciones de programa (sólo modelo 1F80) – Este control puede 11) Selección de bloqueo del compresor (CL) OFF (desactivado) u configurarse para los modos de programación de 5/2 días o 5/1/1 ON (activado) – Si se selecciona CL ON, el termostato esperará días, o para el modo no programable. El ajuste predeterminado es 5 minutos entre ciclos de enfriamiento para evitar que el compresor P2, que corresponde a la opción de programación de 5/2 días. Los realice

Summary of the content on the page No. 14

CÓMO USAR EL TERMOSTATO ¡IMPORTANTE! Elija la configuración del ventilador (Auto/On) Operación manual (omisión del programa) Coloque el interruptor FAN en Auto (automático) u On (activado). Modo programable Auto es la configuración más comúnmente seleccionada y hace Presione o y el botón HOLD y ajuste la temperatura funcionar el ventilador únicamente cuando el sistema de calefacción cuando lo desee. De esta manera omitirá la ejecución del programa. o enfriamiento está encendido. La función H

Summary of the content on the page No. 15

PROGRAMACIÓN (sólo para el modelo programable) Pre-programación de ahorro de energía de fábrica Los termostatos 1F80-0471 están programados con los ajustes de ahorro de energía indicados en la siguiente tabla para todos los días de la semana. Si este programa es adecuado para sus necesidades, simplemente ajuste el reloj del termostato y presione el botón RUN. La siguiente tabla muestra la programación de calefacción y enfriamiento ajustada de fábrica para todos los días de la semana. Al desp

Summary of the content on the page No. 16

SOLUCIÓN DE PROBLEMAS Operación de reajuste Nota: una vez reajustado el termostato, la configuración del menú instalador/de configuración y la programación volverán a los ajustes de fábrica. Si un pico de voltaje o una descarga estática pone en blanco la pantalla o hace que el termostato funcione de manera errática, puede reajustar el termostato retirando los cables de las terminales R y C (no los cortocircuite) y retirando las pilas durante 2 minutos. Después de reajustar el termostato, vue


Alternative user manuals
# User manual Category Download
1 White Rodgers 1.00E+78 User manual Thermostat 49
2 White Rodgers 150 User manual Thermostat 20
3 White Rodgers 1A66 User manual Thermostat 9
4 White Rodgers 1A66W User manual Thermostat 3
5 White Rodgers 1A10 User manual Thermostat 4
6 White Rodgers 1A11-2 User manual Thermostat 7
7 White Rodgers 179 User manual Thermostat 2
8 White Rodgers 1A65 User manual Thermostat 9
9 White Rodgers 1C21 User manual Thermostat 7
10 White Rodgers 1C26 User manual Thermostat 16
11 White Rodgers 1C30(W) User manual Thermostat 3
12 White Rodgers 1A65W User manual Thermostat 3
13 White Rodgers 1D30(W) User manual Thermostat 6
14 White Rodgers 1E30(W) User manual Thermostat 12
15 White Rodgers 1E50N-303 User manual Thermostat 1
16 Edelbrock 2116 User manual Thermostat 0
17 A&D MF-50 User manual Thermostat 8
18 A&D ML-50 User manual Thermostat 8
19 A&D MS-70 User manual Thermostat 15
20 Acu-Rite D1523 User manual Thermostat 2