Trane TZEMT400BB32MAA user manual

User manual for the device Trane TZEMT400BB32MAA

Device: Trane TZEMT400BB32MAA
Category: Thermostat
Manufacturer: Trane
Size: 3.02 MB
Added : 1/23/2014
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Trane TZEMT400BB32MAA. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Trane TZEMT400BB32MAA.

For your convenience

If looking through the Trane TZEMT400BB32MAA user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Trane TZEMT400BB32MAA on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Trane TZEMT400BB32MAA to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Trane TZEMT400BB32MAA User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Trane TZEMT400BB32MAA but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Trane TZEMT400BB32MAA. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Thermostat
Model TZEMT400BB32MAA
Installation, System Setup, and
Enrollment Instructions
TM
To use the remote features of this thermostat, a Schlage LiNK account is required. Schlage LiNK™ online setup requires
broadband internet service and router with available port.
For professional installation service, instructions, operation guide, and installation video modules, please visit link.schlage.com
Customer Service: (877) 288-7707
Customer Service hours of operation:
• Monda y-F r ida y 9

Summary of the content on the page No. 2

3 Determine if your system has a 24 VAC common wire which is required to power the thermostat. • If your system is a heat pump, skip to step 4. a. If y our e xisting ther mostat has a ter minal named C , COM, X, or B with a wire connected to it, skip to step 4. b. If your thermostat does not have that terminal, or does not have a wire connected to it, go to step 3a. 3A Connect a 24 VAC common wire to power the thermostat. a. Locate all unused (disconnected) wires from the d. Locate the the

Summary of the content on the page No. 3

4 Label the wires on your existing thermostat to match terminal names. Y G R • Do not use wire colors to chose labels. The terminal name is what is important. a. Locate the wiring labels located in the box with the new thermostat. b. Look at where each wire is connected to the e xisting ther mostat and find the letter shown next to that wire terminal. c. Peel off the matching label and wrap it around each corresponding wire. Important Notes: ! • If you have a short jumper wire between two t

Summary of the content on the page No. 4

6 Identify your System Type from the list below. You will need to check your wire labels to help identify the system type. START HERE IF START HERE IF OR You have a GAS furnace You have an ELECTRIC furnace or air handler Does NOT have Has a W2 or Y2 wire label W2 or Y2 wire label Does NOT have an Has an O or B O or B wire label wire label Gas Furnace Gas Furnace Single Stage Multi Stage W2 label = multi stage heating Y2 label = multi stage cooling Electric Heat Furnace Pump Does NOT have Has a D

Summary of the content on the page No. 5

24C 24RC G 24RH W1 Y1 Y2 W2/O RS1 RS2 RS2 RS1 H1 HC 24C 24RC 24RH G W1 Y1 W2/O Y2 RS1 RS2 RS1 RS2 H1 HC Y2 24C 24RC 24RH G W1 Y1 W2/O Y2 RS1 RS2 RS1 RS2 H1 HC Y2 7 Separate the face of the new thermostat from the wall plate. Tabs Apply pressure at two tabs on top of wall plate to release it. • NOTE: It is not recommended that this Z-wave thermostat be mounted onto metal structures. Metal may affect the radio frequency (RF) communication between the thermostat and the Z-wave signal to the Sc

Summary of the content on the page No. 6

24C 24RC 24RH G W1 Y1 W2/O Y2 RS1 RS2 RS1 RS2 H1 HC 11 Review the wiring table information. a. Refer to: • T ab le 1 - If y ou do NO T ha v e a heat pump • Table 2 - If you have a heat pump b. Select the correct row based upon the thermostat being replaced, and then circle the wire labels you have. c. Connect your wires as shown in the New Thermostat Terminals row. Some wire terminals may Table 1: Gas or Electric not be used (Single Stage or Multistage) Themostat Being Replaced Wire Labels Al

Summary of the content on the page No. 7

24C 24RC G 24RH W1 Y1 Y2 W2/O RS1 RS2 RS1 RS2 H1 HC Y1 Y2 13 If necessary, cut the internal jumper wire (JP1). If only one wire is connected If wires are connected to to either 24RC or 24RH both 24RC and 24RH as shown as shown Do NOT cut JP1 jumper Cut JP1 jumper RC 24RC RC 24RH 24RC RH W1 24RH OR W1 24RC RH 24RH W1 Cutting the JP1 jumper The jumper is located on back of the thermostat face as shown in the illustration to the right. Cut the jumper using small diagonal cutters being careful not

Summary of the content on the page No. 8

System Settings at Thermostat c. Scroll up or down to Set Clock (it is the first option), then Set Time and Date 16 press the Select button. a. Press the MENU button twice. User Settings 11:15 PM Scroll Set Clock up 68 H Filter Service Maint Service 78 78 C Screen Timeout MENU MODE FAN RUN Done Select Scroll down MENU button Select button b. Scroll up or down to User Settings (it is the first option), d. Press or to highlight the data you want to change. 3 4 then press the Select

Summary of the content on the page No. 9

18A Gas Furnace - Multistage Mechanical Settings a. Press the MENU button twice. 11:15 PM b. Press and hold the two inner buttons for 3 seconds to view 76 H Installer Settings. c. Scroll down to System Settings and press the Select button. 75 74 C d. Scroll to Mechanical Settings (it is the first option), then press the MENU MODE FAN RUN Select button. e. Scroll down to 2nd Stage Heat. f. Press the + button to change the setting to Y for Yes. g. If your system also has 2nd stage

Summary of the content on the page No. 10

Perform System Checkout 19 Test Fan Operation 11:15 PM a. Press the FAN button. b. Scroll to ON. 76 H Sys Off c. V er ify that the system f an star ts and mo v es air . Run 75 74 C d. Press the FAN button. AUTO AUTO e. Scroll to AUTO. MENU MODE FAN RUN f. Press the Done button to return to the home screen. Test Cooling Operation (if your system has cooling) a. Press the MODE button. b. Scroll to COOLING. c. Press the Done button to return to the home screen. FAN MODE d. Turn the tem

Summary of the content on the page No. 11

TM Enroll Thermostat into existing Schlage LiNK System 20 Prepare the Schlage Bridge for enrollment. • If you are using a controller that is not a Schlage Bridge, consult the instructions that came with the controller to find out how to enroll a new device. a. Unplug Ethernet and power cables from Schlage Bridge. Blue b. Install a quality 9 v olt batter y . light c. V er ify that b lue light is b linking. If b lue light is solid, batter y is dead. Replace with ne w 9 v olt batter y , if n

Summary of the content on the page No. 12

23 Establish Online Control of the Thermostat. A Schlage LiNK account is required to complete the setup. If you have an active Schlage LiNK account, continue with the steps below. If you need to create a new account, go to www.schlagelink.com and click on “Just Purchased A Schlage LiNK System?” For more information about the Schlage LiNK system, visit www.link.schlage.com. Completing the setup. a. Remove the battery from the Schlage Bridge. b. Plug the Ethernet and power cord back into the Sch


Alternative user manuals
# User manual Category Download
1 Trane 340 User manual Thermostat 111
2 Trane 350 User manual Thermostat 28
3 Trane TAYSTAT 540 User manual Thermostat 27
4 Trane CT30 User manual Thermostat 23
5 Trane LS-90 User manual Thermostat 14
6 Trane DELUXE programable XT302C User manual Thermostat 64
7 Trane RT-SVX19A-E4 User manual Thermostat 27
8 Trane CA8900 User manual Thermostat 2
9 Trane 18-HD64D1-1 User manual Thermostat 23
10 Trane TCONT900AC43UA User manual Thermostat 64
11 Trane taystat 570 User manual Thermostat 30
12 Trane BAS-SVP10A-EN User manual Thermostat 10
13 Trane Building Automation System User manual Thermostat 14
14 Trane BMTK-SVN01D-EN User manual Thermostat 3
15 Trane CT30 User manual Thermostat 8
16 Edelbrock 2116 User manual Thermostat 0
17 A&D MF-50 User manual Thermostat 8
18 A&D ML-50 User manual Thermostat 8
19 A&D MS-70 User manual Thermostat 15
20 Acu-Rite D1523 User manual Thermostat 2