Summary of the content on the page No. 1
400-115-051-B (Honeywell TH115-AF-GA_GB) 5 x 3.125 EFS.book Page 1 Monday, April 12, 2010 3:10 PM
Owner’s Guide
Guide du propriétaire
Guía para el usuario
TH115-AF-GA / TH115-AF-GB
Programmable thermostat
Thermostat programmable
Termostato programable
400-115-051-B
Summary of the content on the page No. 2
400-115-051-B (Honeywell TH115-AF-GA_GB) 5 x 3.125 EFS.book Page 2 Monday, April 12, 2010 3:10 PM Need Help? We are here to help. Call 1-800-831-2823. Besoin d’aide? Nous sommes là. Composez le 1 800 831-2823. ¿Asistencia? Estamos aquí para ayudarlo. Llame al 1 800 831-2823.
Summary of the content on the page No. 3
400-115-051-B (Honeywell TH115-AF-GA_GB) 5 x 3.125 EFS.book Page 1 Monday, April 12, 2010 3:10 PM TH115-AF-GA / TH115-AF-GB Table of contents Overview Before you start..................................................2 Default schedule ..............................................14 About your thermostat........................................3 Modifying the schedule ....................................15 Controls..............................................................4 Display .......
Summary of the content on the page No. 4
400-115-051-B (Honeywell TH115-AF-GA_GB) 5 x 3.125 EFS.book Page 2 Monday, April 12, 2010 3:10 PM Owner’s Guide Before you start Read the entire document CAUTION: • Installation must be carried out by a certified electrician and must comply with national and local electrical codes. • Use this thermostat for resistive loads only. • Do NOT install the thermostat in an area where it can be exposed to water or rain. • To prevent severe shock or electrocution, always turn the power Off at the serv
Summary of the content on the page No. 5
400-115-051-B (Honeywell TH115-AF-GA_GB) 5 x 3.125 EFS.book Page 3 Monday, April 12, 2010 3:10 PM TH115-AF-GA / TH115-AF-GB About your thermostat The TH115 programmable thermostat has three temperature control modes: A mode: controls the ambient air temperature F mode: controls the floor temperature using an external temperature sensor AF mode: controls the ambient air temperature maintains the floor temperature within desired limits using an external temperature sensor See page 9 on how
Summary of the content on the page No. 6
400-115-051-B (Honeywell TH115-AF-GA_GB) 5 x 3.125 EFS.book Page 4 Monday, April 12, 2010 3:10 PM Owner’s Guide Controls * On/Off switch TEST light/button for ground fault protection (see page 18) Day button Preset temperature buttons Hour button (see page 13) Minutes button Program button ** Backlight button Program clear button ** Temperature adjustment buttons Mode selection / program exit * Place at Off to cut power to the heater (e.g., in the summer). This will not affect the time and
Summary of the content on the page No. 7
400-115-051-B (Honeywell TH115-AF-GA_GB) 5 x 3.125 EFS.book Page 5 Monday, April 12, 2010 3:10 PM TH115-AF-GA / TH115-AF-GB Display Time Day Appears when the setpoint temperature is displayed* Temperature* Operation mode icon Preset temperature icon (see page 13) (see pages 16 & 17) Temperature control mode Number of flames varies (see pages 3 & 9) according to heating intensity Ground fault indicator (see page 18) Period (see page 14) * The thermostat normally displays the actual (measured)
Summary of the content on the page No. 8
400-115-051-B (Honeywell TH115-AF-GA_GB) 5 x 3.125 EFS.book Page 6 Monday, April 12, 2010 3:10 PM Owner’s Guide Installing the thermostat Faceplate Turn the heating system off at the main electrical panel. Loosen the bottom screw and remove the thermostat faceplate from its wallplate. (The screw cannot be completely removed.) Connect the thermostat to the load and to the power supply (see page 7). Connect the floor sensor (see page 8). If you wish to connect a remote control device
Summary of the content on the page No. 9
400-115-051-B (Honeywell TH115-AF-GA_GB) 5 x 3.125 EFS.book Page 7 Monday, April 12, 2010 3:10 PM TH115-AF-GA / TH115-AF-GB Wiring diagram NOTE: Connect the wires using the provided solderless connectors for copper wires. Power Power supply 120 V supply 240 V Black Black Red Red Red White Black Black Black Black Black Black Red White Load Load Red Red 7 ENGLISH
Summary of the content on the page No. 10
400-115-051-B (Honeywell TH115-AF-GA_GB) 5 x 3.125 EFS.book Page 8 Monday, April 12, 2010 3:10 PM Owner’s Guide Connecting the floor sensor / remote control Insert the floor sensor cable through one of the two openings on the wallplate and connect the sensor wires to terminals 1 and 2 (no polarity). • The sensor cable must not come in contact with the electrical wires and must be routed outside the electrical box and follow the wall down to the floor. • Position the sensor cable such that
Summary of the content on the page No. 11
400-115-051-B (Honeywell TH115-AF-GA_GB) 5 x 3.125 EFS.book Page 9 Monday, April 12, 2010 3:10 PM TH115-AF-GA / TH115-AF-GB Set the configuration switches Configuration switches are on the back of the faceplate. # Configurations Up Down 1 Display format °F / 12 h °C / 24 h 1 2 Enable Disable Early Start 2 3 FAF Temperature control mode 1. Early Start is used in Automatic mode only. When Early Start is enabled (on), the thermostat determines when to start heating so the Comfort temperature is
Summary of the content on the page No. 12
400-115-051-B (Honeywell TH115-AF-GA_GB) 5 x 3.125 EFS.book Page 10 Monday, April 12, 2010 3:10 PM Owner’s Guide Time and day To set the clock and the day: Press the Hour button to set the hour. Press the Min button to set the minutes. Press the Day button to set the day. Press the Mode/Ret button to return the thermostat to normal display. NOTE: The thermostat will automatically return to normal display if no button is pressed for 60 seconds. 10 ENGLISH
Summary of the content on the page No. 13
400-115-051-B (Honeywell TH115-AF-GA_GB) 5 x 3.125 EFS.book Page 11 Monday, April 12, 2010 3:10 PM TH115-AF-GA / TH115-AF-GB Daylight Saving Time When the Daylight Saving Time function is enabled (On), the thermostat automatically switches to Daylight Saving Time on the second Sunday of March and to normal time on the first Sunday of November. NOTE: The Daylight Saving Time function is disabled (default setting) when the clock loses its setting. To set the Daylight Saving Time functi
Summary of the content on the page No. 14
400-115-051-B (Honeywell TH115-AF-GA_GB) 5 x 3.125 EFS.book Page 12 Monday, April 12, 2010 3:10 PM Owner’s Guide Floor temperature limits (AF mode only) WARNING: To avoid damaging your floor, follow your floor supplier’s recommendations regarding floor tempera- ture limits. The minimum and maximum floor temperature limits are 5.0°C (41°F) and 28.0°C (82°F) by default. To modify these limits, proceed as follows: Switch the thermostat to Off. Press and hold the button. Switch the therm
Summary of the content on the page No. 15
400-115-051-B (Honeywell TH115-AF-GA_GB) 5 x 3.125 EFS.book Page 13 Monday, April 12, 2010 3:10 PM TH115-AF-GA / TH115-AF-GB Preset temperatures The thermostat has 3 preset temperatures. Their default settings are shown in the following table. Preset temperature Intended use Icon A/AF modes F mode Comfort When at home 21.0°C (70°F) 28.0°C (82°F) Economy When asleep or away from home 17.0°C (63°F) 20.0°C (68°F) Vacation During prolonged absence 10.0°C (50°F) 10.0°C (50°F) To use a preset tem
Summary of the content on the page No. 16
400-115-051-B (Honeywell TH115-AF-GA_GB) 5 x 3.125 EFS.book Page 14 Monday, April 12, 2010 3:10 PM Owner’s Guide Default schedule The schedule consists of 4 periods per day, which represents a typical work day. The Comfort ( ) preset temperature is automatically used in Periods 1 and 3 and the Economy ( ) preset temperature in Periods 2 and 4. You can program the thermostat to skip (cancel) the periods that do not apply to your situation. For example, you can skip periods 2 and 3 for the week
Summary of the content on the page No. 17
400-115-051-B (Honeywell TH115-AF-GA_GB) 5 x 3.125 EFS.book Page 15 Monday, April 12, 2010 3:10 PM TH115-AF-GA / TH115-AF-GB Modifying the schedule Press Pgm. Period 1 for Monday is displayed. To program another period, press Pgm to display that period. To program another day, press Day to display that day (hold for 3 seconds to select the entire week). Press Hour and Min to set the period start time, or press Clear to skip (cancel) the period (--:-- will be displayed). Repeat steps 2
Summary of the content on the page No. 18
400-115-051-B (Honeywell TH115-AF-GA_GB) 5 x 3.125 EFS.book Page 16 Monday, April 12, 2010 3:10 PM Owner’s Guide Running the schedule (Automatic mode) In Automatic mode, the thermostat follows the programmed schedule (see page14). To place the thermostat in this mode, press Mode/Ret until is displayed. Temporary override of schedule If you modify the setpoint temperature (by pressing the , or button) when the thermostat is in Automatic mode, the new temperature will be used until the begin
Summary of the content on the page No. 19
400-115-051-B (Honeywell TH115-AF-GA_GB) 5 x 3.125 EFS.book Page 17 Monday, April 12, 2010 3:10 PM TH115-AF-GA / TH115-AF-GB Permanent override of schedule (Manual mode) To place the thermostat in Manual mode, press Mode/Ret to display on the screen. In this mode, the thermostat does not follow the programmed schedule. Press the , or button to set the temperature. When you go on vacation (Vacation mode) In this mode, the thermostat uses the vacation preset temperature (see page 13). Ther
Summary of the content on the page No. 20
400-115-051-B (Honeywell TH115-AF-GA_GB) 5 x 3.125 EFS.book Page 18 Monday, April 12, 2010 3:10 PM Owner’s Guide Ground fault protection (GFCI) This ground fault protection thermostat is different from conventional thermostats. In the event of a ground fault, the ground fault protection mechanism on the thermostat will trip and quickly stop the flow of electricity to prevent serious injury. Definition of a ground fault Instead of following its normal safe path, electricity passes through a pe