Tektronix P6249 user manual

User manual for the device Tektronix P6249

Device: Tektronix P6249
Category: Thermometer
Manufacturer: Tektronix
Size: 0.56 MB
Added : 4/27/2014
Number of pages: 82
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Tektronix P6249. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Tektronix P6249.

For your convenience

If looking through the Tektronix P6249 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Tektronix P6249 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Tektronix P6249 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Tektronix P6249 User manual - Online PDF
Advertisement
« Page 1 of 82 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Tektronix P6249 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Tektronix P6249. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Instruction Manual
P6249
4 GHz 5X Active Probe
071-0538-03
www.tektronix.com

Summary of the content on the page No. 2

Copyright  Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material. Specifications and price change privileges reserved. Tektronix, Inc., P.O. Box 500, Beaverton, OR 97077 TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. TEKTRONIX, TEK, TEKPROBE, and SureFoot are registered trademarks, and SureToe, FlexLead, and KlipChip are trademarks o

Summary of the content on the page No. 3

WARRANTY Tektronix warrants that the products that it manufactures and sells will be free from defects in materials and workmanship for a period of one (1) year from the date of shipment. If a product proves defective during this warranty period, Tektronix, at its option, either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product. In order to obtain service under this warranty, Customer must notify Tektronix of

Summary of the content on the page No. 4

Summary of the content on the page No. 5

Table of Contents General Safety Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Service Safety Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Product Description Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Standard Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Contacting Tek

Summary of the content on the page No. 6

Table of Contents Specifications Theory of Operation Probe Head and Cable Assembly . . . . . . . . . . . . . . . . . . . . . . . 36 Compensation Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Offset Amplifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Probe Identification EEPROM . . . . . . . . . . . . . . . . . . . . . . . . . 36 TEKPROBE Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 VCC, +7 V Regulat

Summary of the content on the page No. 7

Table of Contents List of Figures Figure 1: Dynamic and offset limitations . . . . . . . . . . . . . . . . . 12 Figure 2: Probe functional check connections . . . . . . . . . . . . . . 13 Figure 3: Deskew fixture connections (two P6249 probes shown) . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Figure 4: Maximum frequency vs. measurement lead length . . 21 Figure 5: Low-inductance grounding . . . . . . . . . . . . . . . . . . . . 23 Figure 6: Using a SureFoot adapter for grounding . .

Summary of the content on the page No. 8

Table of Contents P6249 4 GHz 5X Active Probe Instruction Manual iv

Summary of the content on the page No. 9

General Safety Summary Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential hazards, use this product only as specified. Only qualified personnel should perform service procedures. To Avoid Fire or Personal Injury Connect and Disconnect Properly. Connect the probe output to the measurement instrument before connecting the probe to the circuit under test. Disconnect the probe input and the probe ground from

Summary of the content on the page No. 10

General Safety Summary Safety Terms and Symbols Terms in This Manual. These terms may appear in this manual: WARNING. Warning statements identify conditions or practices that could result in injury or loss of life. CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property. Terms on the Product. These terms may appear on the product: DANGER indicates an injury hazard immediately accessible as you read the marking. WARNING indicates

Summary of the content on the page No. 11

Service Safety Summary Only qualified personnel should perform service procedures. Read this Service Safety Summary and the General Safety Summary before performing any service procedures. Do Not Service Alone. Do not perform internal service or adjustments of this product unless another person capable of rendering first aid and resuscitation is present. P6249 4 GHz 5X Active Probe Instruction Manual vii

Summary of the content on the page No. 12

Service Safety Summary P6249 4 GHz 5X Active Probe Instruction Manual viii

Summary of the content on the page No. 13

Product Description The Tektronix P6249 is a 4 GHz (probe only), 5X active FET probe with 1 pF input capacitance. The P6249 has a low input capacitance and high input resistance which minimize circuit loading over a wide bandwidth range. The small profile and low-mass head of the P6249 make probing crowded circuits by hand fast and easy. The accessory tips and adapters included with the probe enable the P6249 to be used on a wide variety of circuit architectures. The P6249 is powered through a T

Summary of the content on the page No. 14

Product Description  Right-angle adapter  Three-inch ground lead  Low-inductance ground pogo pin  Color marker bands  SMK4 Micro KlipChip adapters  .100” square pin adapter  Instruction manual Optional Accessories The following accessories are available for the P6249 probe:  Deskew fixture  Probe tip-to-SMA adapter  1103 Probe Power Supply  Compensation box release tool  Insulated adjustment tool Refer to Features and Accessories on page 5 for more information on using the probe and

Summary of the content on the page No. 15

Product Description Contacting Tektronix Phone 1-800-833-9200* Address Tektronix, Inc. Department or name (if known) 14200 SW Karl Braun Drive P.O. Box 500 Beaverton, OR 97077 USA Web site www.tektronix.com Sales 1-800-833-9200, select option 1* support Service 1-800-833-9200, select option 2* support Technical Email: techsupport@tektronix.com support 1-800-833-9200, select option 3* 6:00 a.m. – 5:00 p.m. Pacific time * This phone number is toll free in North America. After office hours, please

Summary of the content on the page No. 16

Product Description P6249 4 GHz 5X Active Probe Instruction Manual 4

Summary of the content on the page No. 17

Features and Accessories The P6249 is provided with several features and accessories designed to make probing and measurement a simpler task. Please familiarize yourself with these items and their uses. Probe head assembly. The probe head is designed for ease of use and high performance. Its small size makes it easy to handle in tight areas. Probe tip socket The probe tip socket is sized to easily press onto 0.025 inch pins for direct access. The ground Ground socket provides a short ground pat

Summary of the content on the page No. 18

Features and Accessories Installing the push-in probe tip. Attach the push-in probe tip by seating the tip into the probe tip socket and pushing the tip in until it is seated. Either end of the tip may be used. Do not force the tip. Also, be careful not to poke yourself with the sharp probe-tip. To remove the tip, gently grab the tip with small pliers and pull the tip out. SureFoot probe tip. The SureFoot tip is an integral probe tip and miniature guide that enables fault-free probing of fin

Summary of the content on the page No. 19

Features and Accessories SureToe probe tip. The SureToe tip is a pointed probe tip useful for probing in dense circuitry. Attach the SureToe adapters the same way as the push-in probe tips. Do not force the tip. Also, be careful not to poke yourself with the sharp probe tip. They can be used with any of the socketed accessory leads. Right-angle adapter. Use the right-angle adapter for low-profile probing of 0.025 inch diameter square pins. The right-angle adapter allows the probe to lie flat aga

Summary of the content on the page No. 20

Features and Accessories Three-inch ground lead. Use the three-inch ground lead for general probing. The socketed end of the lead may be connected to any of the probe tips and adapters or fitted onto 0.025 inch pins. To attach the ground lead, press and rotate the lead pin connector into the ground socket on the probe head. The lead may be removed by simply pulling the pin out by hand. When selecting the grounding connection, maintain as short a ground path as possible. Refer to page 20 for more


Alternative user manuals
# User manual Category Download
1 Tektronix P6131 User manual Thermometer 5
2 Tektronix 070-9472-02 User manual Thermometer 0
3 Tektronix P7225 User manual Thermometer 0
4 Tektronix P6230 User manual Thermometer 5
5 Tektronix P7240 User manual Thermometer 1
6 A&D DT-103 User manual Thermometer 40
7 A&D DT-102 User manual Thermometer 24
8 A&D UT-302 User manual Thermometer 15
9 Acu-Rite 416 User manual Thermometer 7
10 Acu-Rite #00609SBDIA1 User manual Thermometer 3
11 Acu-Rite 418 User manual Thermometer 3
12 Acu-Rite 420 User manual Thermometer 2
13 Acu-Rite 888 User manual Thermometer 0
14 Acu-Rite 00591W User manual Thermometer 0
15 Acu-Rite 617 User manual Thermometer 0