RayTek MI Miniature Infrared Sensor user manual

User manual for the device RayTek MI Miniature Infrared Sensor

Device: RayTek MI Miniature Infrared Sensor
Category: Thermometer
Manufacturer: RayTek
Size: 2.17 MB
Added : 2/26/2014
Number of pages: 95
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for RayTek MI Miniature Infrared Sensor. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with RayTek MI Miniature Infrared Sensor.

For your convenience

If looking through the RayTek MI Miniature Infrared Sensor user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual RayTek MI Miniature Infrared Sensor on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual RayTek MI Miniature Infrared Sensor to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
RayTek MI Miniature Infrared Sensor User manual - Online PDF
Advertisement
« Page 1 of 95 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual RayTek MI Miniature Infrared Sensor but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to RayTek MI Miniature Infrared Sensor. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

 
MI
Miniature Infrared Sensor
 
 
 
 
 
 
 
 
 
 
 
 
 
Operating Instructions







Rev. F 04/2006
54301

Summary of the content on the page No. 2

      Declaration of Conformity for the European Community This instrument conforms to:  EMC:  IEC/EN 61326‐1  Safety:  EN 61010‐1:1993 / A2:1995       

Summary of the content on the page No. 3

  Contacts  Europe  USA  Raytek GmbH  Raytek Corporation  13127 Berlin, Germany  CA 95061 – 1820, Santa Cruz  Blankenburger Str. 135  1201 Shaffer Rd. PO Box 1820  Tel:  +49 30 478008 – 0  Tel:  +1 831 458 – 1110 or    +49 30 478008 – 400    +1 800 227 – 8074  Fax:  +49 30 4710251  Fax:  +1 831 458 – 1239  raytek@raytek.de  automation@raytek.com  United Kingdom  France  Tel:  +44 1908 630800  Tel:  0800 888 244  Fax:  +44 1908 630900    ukinfo@raytek.com  info@raytek.fr  Raytek China Company   

Summary of the content on the page No. 4

  WARRANTY  The manufacturer warrants this instrument to be free from defects in  material and workmanship under normal use and service for the  period of two years from date of purchase. This warranty extends  only to the original purchaser. This warranty shall not apply to fuses,  batteries, or any product that has been subject to misuse, neglect,  accident, or abnormal conditions of operation.  In the event of failure of a product covered by this warranty, the  manufacturer will repair the in

Summary of the content on the page No. 5

  TABLE OF CONTENTS  1 SAFETY INSTRUCTIONS............................................1 2 DESCRIPTION...............................................................3 3 TECHNICAL DATA......................................................4 3.1 MEASUREMENT SPECIFICATIONS...............................4 3.2 OPTICAL SPECIFICATIONS..........................................6 3.3 ELECTRICAL SPECIFICATIONS....................................7 3.4 ENVIRONMENTAL SPECIFICATIONS........................

Summary of the content on the page No. 6

  5.3.1 Signal Output...................................................19 5.3.2 Head Ambient Temp. / Alarm Output.............20 5.3.3 Thermocouple Output.......................................22 5.4 INPUTS FTC..............................................................23 5.4.1 Emissivity Setting (analog controlled).............24 5.4.2 Emissivity Setting (digital controlled).............25 5.4.3 Ambient Background Temperature  Compensation...............................................

Summary of the content on the page No. 7

  8 ACCESSORIES.............................................................46 8.1 OVERVIEW................................................................46 8.2 ADJUSTABLE MOUNTING BRACKET.........................48 8.3 FIXED MOUNTING BRACKET....................................49 8.4 AIR PURGING JACKET...............................................50 8.5 AIR COOLING SYSTEM..............................................52 8.6 RIGHT ANGLE MIRROR............................................57

Summary of the content on the page No. 8

  11.6.2 Analog Output, Scaling.................................73 11.6.3 Alarm Output.................................................73 11.6.4 Factory default values.....................................73 11.6.5 Lock Mode.......................................................74 11.6.6 Mode Setting for the Digital Input FTC3.......74 11.6.7 Changing the Sensing Head Calibration Data74 11.6.8 Ambient Background Temperature  Compensation......................................................

Summary of the content on the page No. 9

Safety Instructions  1 Safety Instructions  This  document  contains  important  information,  which  should  be  kept at all times with the instrument during its operational life. Other  users of this instrument should be given these instructions with the  instrument. Eventual updates to this information must be added to  the original document. The instrument should only be operated by  trained personnel in accordance with these instructions and local  safety regulations.  Acceptable Operation 

Summary of the content on the page No. 10

Safety Instructions  Operating Instructions  The  following  symbols  are  used  to  highlight  essential  safety  information in the operation instructions:  Helpful  information  regarding  the  optimal  use  of  the  instrument.  Warnings  concerning  operation  to  avoid  instrument  damage.  Warnings concerning operation to avoid personal injury.  Pay particular attention to the following safety instructions.  Use  in  110  /  230  VAC  electrical  systems  can  result  in  electrical  haza

Summary of the content on the page No. 11

Description  2 Description  The  miniature  infrared  sensors  MI  are  noncontact  infrared  temperature measurement systems. They accurately and repeat ably  measure the amount of energy emitted from an object and convert  that energy into a temperature signal.  The following outputs are available:  • J‐Thermocouple  • K‐Thermocouple  • 0 ‐ 5 Volt  • 0 ‐ 20 mA or 4 ‐ 20 mA  • 10 mV / °C head ambient temperature signal  • RS232 interface  • optional: RS485 interface  The sensing head is protect

Summary of the content on the page No. 12

Technical Data  3 Technical Data  3.1 Measurement Specifications  Temperature Range  LT ‐40 to 600°C (‐40 to 1112°F)  for J‐Thermocouple: ‐25 to 600°C (‐13 to 1112°F)  Spectral Response   LT  8 to 14 μm  Response Time  All models  150 ms (95% response)  Accuracy  LT  ± 1% or ± 1°C (± 2°F) whichever is greater  LT  ± 2°C (± 4°F) for target temp. < 20°C (68°F)  TC outputs  ± 1% or ± 2.5°C (± 5°F) whichever is greater  At ambient temperature 23°C ±5°C (73°F ±9°F)  Repeatability  All models  ± 0.5% 

Summary of the content on the page No. 13

Technical Data  Temperature Resolution  LT  ± 0.1 K (± 0.2°F)*    ± 0.25 K (± 0.5°F)**  * For a zoomed temperature span of 300°C (600°F)  ** For the full temperature range of the unit  Temperature Coefficient  MIC  ± 0.05 K per K or ± 0,05% / K whichever is  greater, at ambient: 23 to 125°C (73 to 185°F)  MIH  ± 0.05 K per K or ± 0,05% / K whichever is  greater, at ambient: 23 to 180°C (73 to 356°F)  MIC, MIH  ± 0.1 K per K or ± 0.1% per K whichever is  greater, at ambient: 0 to 23°C (32 to 73°F

Summary of the content on the page No. 14

Technical Data  3.2 Optical Specifications  Optical Resolution D:S  MID, MIC; MIH  22:1 (typ.), 21:1 (guaranteed)  MID, MIC; MIH  10:1  MID, MIC  2:1  At 90% energy in minimum and distance 400 mm (15.7 in.)    Figure 1: Spot Size Chart  6  MI 

Summary of the content on the page No. 15

Technical Data  3.3 Electrical Specifications  Power Supply  Voltage  12 to 26 VDC  Current  100 mA  Outputs  1. Output (OUT)  0 to 20 mA, or  4 to 20 mA, or  0 to 5 V, or  Thermocouple (J or K)  2. Output (AMB) 0 to 5 V output for head ambient temperature  (0 to 500°C, 32 to 932°F) or output for alarm  relay (software enabled, only in conjunction  with RS232/485)  mA Output  recommended loop impedance see Figure 9 on  page 19.  0 to 5 V Outputs  min. load impedance 100 kΩ (a lower load  impedan

Summary of the content on the page No. 16

Technical Data  3.4 Environmental Specifications  Ambient Temperature  MIH sensing head  0 to 180°C (32 to 356°F)  MIC sensing head  0 to 125°C (32 to 257°F)  MID sensing head  0 to 85°C (32 to 185°F)  MID with air cooling ‐18 to 200°C (0 to 392°F)  Electronics box  0 to 65°C (32 to 150°F)  Storage Temperature  ‐10 to 85°C (14 to 185°F)  Rating (Head)  IP 65 (NEMA‐4), not for models with an  optical resolution of 2:1  Rating (Box)  IP 65 (NEMA‐4)  Relative Humidity  10% to 95% non‐condensing  EM

Summary of the content on the page No. 17

Technical Data  3.5 Dimensions  Standard cable length 1 m (3 ft.) MID/MIC: Ø 5 mm (0.2 in) MIH: Ø 3 mm (0.12 in)   Figure 2: Dimensions of Sensing Head  2 mounting holes, Ø 4.5 mm (0.17 in)   MI  9 

Summary of the content on the page No. 18

Technical Data    Figure 3: Dimensions of Electronic Box  3.6 Scope of Delivery  The scope of delivery includes the following:  • Sensing head  • 1 m head cable  • Mounting nut  • Electronic box  • Operating instructions  10  MI 

Summary of the content on the page No. 19

Basics  4 Basics  4.1 Measurement of Infrared Temperature  All surfaces emit infrared radiation The intensity of this infrared  radiation  changes  according  to  the  temperature  of  the  object.  Depending  on  the  material  and  surface  properties,  the  emitted  radiation lies in a wavelength spectrum of approximately 1 to 20 μm.  The intensity of the infrared radiation (”heat radiation”) is dependent  on  the  material.  For  many  substances  this  material‐dependent  constant is known.

Summary of the content on the page No. 20

Basics  4.2 Emissivity of Target Object  To determine the emissivity of the target object refer to section 12.1  Determination  of  Emissivity  on  page  81.  If  emissivity  is  low,  measured results could be falsified by interfering infrared radiation  from background objects (such as heating systems, flames, fireclay  bricks, etc. close beside or behind the target object). This type of  problem can occur when measuring reflective surfaces and very thin  materials such as plastic films and gl


Alternative user manuals
# User manual Category Download
1 RayTek 3i User manual Thermometer 126
2 RayTek Raynger MX Series User manual Thermometer 370
3 RayTek 54301 User manual Thermometer 10
4 RayTek MARATHON FR User manual Thermometer 67
5 RayTek MARATHON FA User manual Thermometer 23
6 RayTek Raynger ST ST30 User manual Thermometer 135
7 RayTek FoodPro Food Safety s User manual Thermometer 28
8 RayTek Raynger ST ST20 User manual Thermometer 355
9 A&D DT-103 User manual Thermometer 40
10 A&D DT-102 User manual Thermometer 24
11 A&D UT-302 User manual Thermometer 15
12 Acu-Rite 416 User manual Thermometer 7
13 Acu-Rite #00609SBDIA1 User manual Thermometer 3
14 Acu-Rite 418 User manual Thermometer 3
15 Acu-Rite 420 User manual Thermometer 2