RayTek MARATHON FA user manual

User manual for the device RayTek MARATHON FA

Device: RayTek MARATHON FA
Category: Thermometer
Manufacturer: RayTek
Size: 3.48 MB
Added : 2/26/2014
Number of pages: 67
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for RayTek MARATHON FA. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with RayTek MARATHON FA.

For your convenience

If looking through the RayTek MARATHON FA user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual RayTek MARATHON FA on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual RayTek MARATHON FA to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
RayTek MARATHON FA User manual - Online PDF
Advertisement
« Page 1 of 67 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual RayTek MARATHON FA but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to RayTek MARATHON FA. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


MARATHON
FA/FR Series
1-Color Fiber Optic Thermometer
2-Color Fiber Optic Thermometer 
 
 
Operating Instructions
















Rev. G 01/2010
53001

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Contacts    Worldwide Headquarters     Santa Cruz, CA USA  Tel:  +1 800 227 – 8074 (USA and Canada only)    +1 831 458 – 3900  Fax:  +1 831 458 – 1239  solutions@raytek.com  European Headquarters  France  United Kingdom  Berlin, Germany    Tel:  +44 1908 630 800  Tel: +49 30 4 78 00 80  info@raytek.fr  ukinfo@raytek.com  raytek@raytek.de  Fluke Service Center     Beijing, China  Tel:  +86 10 6438 691  Tel:  +86 10 4008103435 (Service)  info@raytek.com.cn  Internet: http://www.raytek.com/    Th

Summary of the content on the page No. 4

WARRANTY  The manufacturer warrants this instrument to be free from defects in material and workmanship  under normal use and service for the period of two years from date of purchase. This warranty  extends only to the original purchaser. This warranty shall not apply to fuses, batteries, or any  product that has been subject to misuse, neglect, accident, or abnormal conditions of operation.  In the event of failure of a product covered by this warranty, the manufacturer will repair the  inst

Summary of the content on the page No. 5

TABLE OF CONTENTS  1 SAFETY INSTRUCTIONS..............................................................................................................................1 2 PRODUCT DESCRIPTION............................................................................................................................2 2.1 THEORY OF OPERATION FOR 2‐COLOR SENSORS.........................................................................................2 2.1.1 Partially Obscured Targets..............

Summary of the content on the page No. 6

6 OPERATION...................................................................................................................................................25 6.1 CONTROL PANEL.......................................................................................................................................25 6.2 OPERATION MODES...................................................................................................................................26 6.2.1 Temperature Display.

Summary of the content on the page No. 7

10.4.2.1 Attaching the Fiber Optic Cable to the Optical Head..........................................................51 10.4.2.2 Attaching the Fiber Optic Cable to the Electronics Housing..............................................51 10.4.3 Fiber Calibration...............................................................................................................................52 11 APPENDIX.............................................................................................

Summary of the content on the page No. 8

Summary of the content on the page No. 9

Safety Instructions 1 Safety Instructions  This document contains important information, which should be kept at all times with the instrument  during its operational life. Other users of this instrument should be given these instructions with the  instrument. Eventual updates to this information must be added to the original document. The  instrument can only be operated by trained personnel in accordance with these instructions and local  safety regulations.  Acceptable Operation  This instru

Summary of the content on the page No. 10

Product Description 2 Product Description  The Marathon FA/FR fiber optic series of instruments are high‐performance infrared thermometers.  Each has a front end consisting of a small, fixed focus optical head coupled to a rugged fiber optic  cable wrapped with a flexible stainless steel sheath. The fiber optic cable attaches to an electronics  enclosure, which can be mounted away from the hot, hostile environment. The electronics enclosure  can be connected to a computer with its two‐way RS485

Summary of the content on the page No. 11

Product Description Another benefit is that 2‐color sensors measure closer to the highest temperature within the measured  spot (spatial peak picking) instead of an average temperature. A 2‐color sensor can be mounted farther  away, even if the target does not fill the resulting spot size. The convenience is that you are not forced  to  install  the  sensor  at  some  specific  distance  based  upon  target  size  and  the  sensor’s  optical  resolution.  2.1.1 Partially Obscured Targets  The r

Summary of the content on the page No. 12

Technical Data 3 Technical Data  3.1 Measurement Specifications  3.1.1 FA Models  Temperature Range  FA1A  475 to 900°C (887°F to 1652°F)  FA1B  800 to 1900°C (1472°F to 3452°F)  FA1C  1200 to 3000°C (2192°F to 5432°F)  FA1G  750 to 1675°C (1382°F to 3047°F)  FA2A  250 to 800°C (482°F to 1472°F)  FA2B  400 to 1700°C (752°F to 3092°F)  Spectral Response  FA1  1.0 μm (Si detector)  FA2  1.6 μm (InGaAs detector)  1 System Accuracy   FA1/FA2  ±(0.3% Tmeas + 2°C), Tmeas in °C  FA1G  ±3°C  Repeatabil

Summary of the content on the page No. 13

Technical Data 1 System Accuracy   * no signal attenuation  ±(0.3% Tmeas  + 2°C)  * up to 95% signal attenuation  ±(1% Tmeas  + 2°C) for FR1A/FR1B  * up to 95% signal attenuation  ±(1.3% Tmeas  + 2°C) for FR1C  *  Tmeas in °C  see also appendix 11.4 and 11.5, pages 57 ff.  Repeatability  ±1°C (±2°F)  Temperature Resolution  ±1°C (±2°F)  Response Time  10 msec (95%), selectable to 10 sec  Temperature Coefficient  ±0.1% of reading at ambient temperature from 0 to 60°C  Emissivity (1‐color)  0.10 

Summary of the content on the page No. 14

Technical Data Warm up Period  15 minutes  Weight  Optical Head  100 g (3.5 oz)  Electronics Housing  710 g (9 oz)  3.3 Electrical Specifications  Power Supply  24 VDC ±20%, 500 mA (max 100 mV peak to peak of ripple)  Power Consumption  max. 12 W  Output Isolation  500 V AC or DC provided by manufacturer supplied power  supply accessory  Dielectric Withstand Voltage  500 V  Outputs  Analog  0 ‐ 20 mA, 4 ‐ 20 mA, 16 bit resolution  max current loop impedance: 500  Ω  Digital RS485  networkable t

Summary of the content on the page No. 15

Technical Data 3.4 Dimensions  Fiber Optic Cable min. bend radius   Figure 2: Dimensions of Optical Head(FA Models)  Fiber Optic Cable min. bend radius   Figure 3: Dimensions of Optical Head (FR Models)  Mounting hole ∅ 5 mm (0.188) Max. fastener head 8 mm (0.31) Hole diameter: 21 mm (0.83)   Figure 4: Dimensions of Electronics Housing  Marathon Series FA/FR  7

Summary of the content on the page No. 16

Technical Data   Figure 5: Adjustable Mounting Bracket for Optical Head  8  Marathon Series FA/FR

Summary of the content on the page No. 17

Technical Data 3.5 Optical Specifications  The sensor comes as a standard focus model or one of two close focus models, see following overview  for available options. For one‐color temperature measurements make sure the target completely fills  the measurement spot.  3.5.1 FA Models  3.5.1.1 Standard Focus  [inch] [inch] FA1A/FA2A SF FA1B/FA1C/FA1G SF Distance D to Object [mm] Distancse D to Object [mm] D:S = 100:1 at focus point D:S = 20:1 at focus point [inch] FA2B SF   Distance D to Ob

Summary of the content on the page No. 18

Technical Data 3.5.1.2 Close Focus  [inch] [inch] FA1A/FA2A CF1 FA1A/FA2A CF2 Distance D to Object [mm] Distance D to Object [mm] D:S = 20:1 at focus point D:S = 20:1 at focus point [inch] [inch] FA1B/FA1C CF1 FA1B/FA1C CF2 Distance D to Object [mm] Distance D to Object [mm] D:S = 100:1 at focus point D:S = 100:1 at focus point [inch] [inch] FA2B CF1 FA2B CF2   Distance D to Object [mm] Distance D to Object [mm] D:S = 40:1 at focus point D:S = 40:1 at focus point Figure 7: Close Focu

Summary of the content on the page No. 19

Technical Data 3.5.2 FR Models  3.5.2.1 Standard Focus  [inch] [inch] FR1A SF FR1B SF Distance D to Object [mm] Distance D to Object [mm] D:S = 20:1 at focus point D:S = 40:1 at focus point [inch] FR1C SF   Distance D to Object [mm] D:S = 65:1 at focus point Figure 8: Standard Focus Spot Size Charts for FR models  Marathon Series FA/FR  11 Spot ∅ Spot ∅ S [mm]  S [inch] Spot ∅ Spot ∅ S [mm]  S [inch] Spot ∅ Spot ∅ S [mm]  S [inch]

Summary of the content on the page No. 20

Technical Data 3.5.2.2 Close Focus  [inch] [inch] FR1A CF1 FR1A CF2 Distance D to Object [mm] Distance D to Object [mm] D:S = 20:1 at focus point D:S = 20:1 at focus point [inch] [inch] FR1B CF1 FR1B CF2 Distance D to Object [mm] Distance D to Object [mm] D:S = 40:1 at focus point D:S = 40:1 at focus point [inch] [inch] FR1C CF1 FR1C CF2   Distance D to Object [mm] Distance D to Object [mm] D:S = 65:1 at focus point D:S = 65:1 at focus point Figure 9: Close Focus Spot Size Charts for F


Alternative user manuals
# User manual Category Download
1 RayTek 3i User manual Thermometer 126
2 RayTek Raynger MX Series User manual Thermometer 370
3 RayTek 54301 User manual Thermometer 10
4 RayTek MARATHON FR User manual Thermometer 67
5 RayTek Raynger ST ST30 User manual Thermometer 135
6 RayTek FoodPro Food Safety s User manual Thermometer 28
7 RayTek Raynger ST ST20 User manual Thermometer 355
8 RayTek MI Miniature Infrared Sensor User manual Thermometer 141
9 A&D DT-103 User manual Thermometer 40
10 A&D DT-102 User manual Thermometer 24
11 A&D UT-302 User manual Thermometer 15
12 Acu-Rite 416 User manual Thermometer 7
13 Acu-Rite #00609SBDIA1 User manual Thermometer 3
14 Acu-Rite 418 User manual Thermometer 3
15 Acu-Rite 420 User manual Thermometer 2