Omega Vehicle Security HH507 user manual

User manual for the device Omega Vehicle Security HH507

Device: Omega Vehicle Security HH507
Category: Thermometer
Manufacturer: Omega Vehicle Security
Size: 0.19 MB
Added : 3/30/2013
Number of pages: 15
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Omega Vehicle Security HH507. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Omega Vehicle Security HH507.

For your convenience

If looking through the Omega Vehicle Security HH507 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Omega Vehicle Security HH507 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Omega Vehicle Security HH507 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Omega Vehicle Security HH507 User manual - Online PDF
Advertisement
« Page 1 of 15 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Omega Vehicle Security HH507 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Omega Vehicle Security HH507. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

OMEGA
HH507
Digital Thermometer

Summary of the content on the page No. 2

TM omega.com SM OMEGAnet On-Line Service Internet e-mail http://www.omega.com info@omega.com Servicing North America: USA: ISO 9001 Certified Canada: One Omega Drive, Box 4047 976 Bergar Stamford, CT 06907-0047 Laval (Quebec) H7L5A1 Tel: (203) 359-1660 Tel: (514) 856-6928 FAX: (203)359-7700 FAX: (514) 856-6886 e-mail: info@omega.com e-mail: info@omega.com For immediate technical or application assistance: USA and Canada: Mexico and Latin America: SM SM Sales Service: 1-800-826-6342 / 1-800-TC-OM

Summary of the content on the page No. 3

INTRODUCTION This instrument is a 4½ digit, compact-sized portable digital thermometer designed to use external K/J/T/E/R/S/N-type thermocouples as temperature sensor. Temperature indication follows Reference Temperature/Voltage Tables (N.I.S.T. Monograph 175 Revised to ITS-90) for K/J/T/E/R/S/N-type thermo- couples. One K-type thermocouple are supplied with the thermometer. SAFETY INFORMATION It is recommended that you read the safety and operation instructions before using the thermometer. WA

Summary of the content on the page No. 4

SPECIFICATIONS ELECTRICAL Temperature Scale: Celsius or Fahrenheit user-selectable Measurement Range: Thermocouple Range K-TYPE -200°C to 1372°C, -328°F to 2501°F J-TYPE -210°C to 1050°C, -346°F to 1922°F T-TYPE -200°C to 400°C, -328°F to 752°F E-TYPE -210°C to 790°C, -346°F to 1454°F R-TYPE 0°C to 1767°C, 32°F to 3212°F S-TYPE 0°C to 1767°C, 32°F to 3212°F N-TYPE -50°C to 1300°C, -58°F to 2372°F Resolution: K-TYPE 0.1°C, 0.1°F (0°F to 700°F) 0.2°F on other range J-TYPE 0.1°C, 0.1°F (0°F to 500°

Summary of the content on the page No. 5

Accuracy: Accuracy is specified for operating temperatures over the range of 18°C to 28°C (64°F to 82°F), for 1 year, not including thermocouple error. K/J/T/E-TYPE ±(0.05% rdg + 0.3°C) -50°C to 1370°C ±(0.05% rdg + 0.7°C) -50°C to -210°C ±(0.05% rdg + 0.6°F) -58°F to 2498°F ±(0.05% rdg + 1.4°F) -58°F to -346°F N-TYPE ±(0.05% rdg + 0.7°C) -50°C to 0°C ±(0.05% rdg + 0.3°C) 0°C to 1300°C ±(0.05% rdg + 1.4°F) -58°F to 32°F ±(0.05% rdg + 0.6°F) 32°F to 2372°F R/S-TYPE ±(0.05% rdg + 2°C) 0°C to 1767°

Summary of the content on the page No. 6

ENVIRONMENTAL Ambient Operating Ranges: 0°C to 50°C (32°F to 122°F) <80% R.H. Storage Temperature: -20°C to 60°C (-4°F to 140°F) <70% R.H. GENERAL Display: 4½ digit liquid crystal display (LCD) with maximum reading of 9999.9. Overload: "----.-" is display. Battery: Standard 9V battery. Battery Life: 100 hours typical with carbon zinc battery. Auto power off: The meter key switch inactive for more than 30 minutes, press power key to resume operation. Dimensions: 192mm(H) x 91mm(W) x 52.5mm(D). We

Summary of the content on the page No. 7

OPERATING INSTRUCTIONS 1 Power Switch The key turns the thermometer on or off. In the MIN MAX record mode can not power off, must leave MIN MAX record mode then power off. 2 °C/°F Selecting the Temperature Scale Readings are dual displayed in either degrees Celsius(°C) or degrees Fahrenheit(°F). When the thermometer is turned on, it is set to the temperature scale that was in use when the thermometer was last turned off. To change the temperature scale, press the °C/°F key. 3 HOLD Mode

Summary of the content on the page No. 8

4 TIMER STOP-WATCH Mode Press TIMER STOP-W key to enter stop-watch mode stop-watch is displayed in second display. Press start/stop key to toggle stop-watch starts and stops (Time goes up to 99 minutes & 59.9 seconds). In the this mode the automatic power-off feature is disabled. Pess Clear key to zero the stop-watch. Press TIMER STOP-W key again to exit the stop-watch mode. 5 K/J/T/E/R/S/N T1 Input Thermocouple Type Select (Main display) The TYPE key circulating selects the K/J/T/E/R/S/N type t

Summary of the content on the page No. 9

Push MIN MAX key to cycle through the Max/Min/Avg/Present readings. If an overload is recorded, the averaging function is stopped and average value display"----.-". The true average of all the reading taken over at least 22 hours preiod can be displayed. If 22 hours is exceeded, new averages are no longer calculated. The last calcalated value is retained as the average reading, but the actual minimum and maximum reading will continue to be captured. In the this mode, press HOLD key to stop the r

Summary of the content on the page No. 10

8 Hi/Lo LIMITS mode (only Main display) Press Hi/Lo LIMITS key to enter the Hi/Lo Limits comparative mode, "LIMIT" is displayed. In the this mode the automatic power-off feature is disabled and REL key, HOLD key, MAX/MIN key are disabled, when input temperature value exceed Hi. The beeper emits a continuity pulse tone and "Hi" is displayed, and when input temperature value exceed Lo value. The beeper emits a discontinuous pulse tone and "Lo" is displayed. Press Hi/Lo LIMIT key again to exit the

Summary of the content on the page No. 11

3. Time set mode, (Press ENTER key can escape Time set mode) = = : = = = = is displayed in third display. Time (hours, minutes, seconds) value is entered via overlay numbers, then press overlay ENTER key. Time start from set time value and exit set mode. 10 Relative value Recall display mode Press REL RECALL key to display the Relative set value on second display. Press REL RECALL key again to exit this mode. 11 Hi/Lo Limits value Recall display mode Press Hi/Lo RECALL key to display the Hi set

Summary of the content on the page No. 12

OPERATOR MAINTENANCE WARNING To avoid possible electrical shock, disconnect the thermocouple connectors from the thermometer before removing the cover. Battery Replacement Power is supplied by a 9 volt "transistor" battery. The " " appears on the LCD display when replacement is needed. To replace the battery, remove the two screws from the back of the meter and lift off the battery cover. Remove the battery from battery contacts. 10

Summary of the content on the page No. 13

HH 506(R)/HH 507(R) CALIBRATION PROCEDURE Note: The following calibration procedure should perform only by qualified technicians who have access to the items as following. Equipment: The class of calibrator had better 10 times greater than the measured meter. 1. Set the jumper position on J1 position. 2. Input DCV 17mV to the T1 after the display is stabilized (forward 4 digits), then press “ HOLD “ key and "0.0" is displayed in main display. 3. Input DCV 60mV after the display is stabilized (fi

Summary of the content on the page No. 14

WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA's customers receive maximum coverage on each product.If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA's Customer Service Departme

Summary of the content on the page No. 15

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA...Of Course! TEMPERATURE DATA ACQUISITION þ Thermocouple, RTD & Thermistor þ Data Acquisition & Probes, Connectors, Panels & Assemblies Engineering Software þ Wire: Thermocouple, RTD & Thermistor þ Communications-Based þ Calibrators & Ice Point References Acquisition Systems þ Recorders, Controllers & Process Monitors þ Plug-in Cards for Apple, IBM þ Infrared Pyrometers & Compatibles þ Datalogging Systems PRESSURE/STRAI


Alternative user manuals
# User manual Category Download
1 Omega Vehicle Security A User manual Thermometer 0
2 Omega Vehicle Security CL3512A User manual Thermometer 0
3 Omega Vehicle Security DP97 User manual Thermometer 0
4 Omega Vehicle Security HH501AJ User manual Thermometer 0
5 Omega Vehicle Security HH501AT User manual Thermometer 0
6 Omega Vehicle Security HH501BE User manual Thermometer 0
7 Omega Vehicle Security DialtempTM B User manual Thermometer 0
8 Omega Vehicle Security HH-21 User manual Thermometer 3
9 Omega Vehicle Security HH501BJ User manual Thermometer 0
10 Omega Vehicle Security HH501BT User manual Thermometer 0
11 Omega Vehicle Security HH2100 Series User manual Thermometer 0
12 Omega Vehicle Security HH501BK User manual Thermometer 1
13 Omega Vehicle Security HH503 User manual Thermometer 0
14 Omega Vehicle Security HH502 User manual Thermometer 1
15 Omega Vehicle Security HHLM-2 User manual Thermometer 0
16 A&D DT-103 User manual Thermometer 40
17 A&D DT-102 User manual Thermometer 24
18 A&D UT-302 User manual Thermometer 15
19 Acu-Rite 416 User manual Thermometer 7
20 Acu-Rite #00609SBDIA1 User manual Thermometer 3