Omega OS541 user manual

User manual for the device Omega OS541

Device: Omega OS541
Category: Thermometer
Manufacturer: Omega
Size: 0.68 MB
Added : 3/19/2013
Number of pages: 10
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Omega OS541. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Omega OS541.

For your convenience

If looking through the Omega OS541 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Omega OS541 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Omega OS541 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Omega OS541 User manual - Online PDF
Advertisement
« Page 1 of 10 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Omega OS541 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Omega OS541. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

User’s Guide
Shop online at
www.omega.com
e-mail: info@omega.com
CAUTION
LASER RADIATION
DO NOT STARE INTO BEAM
WAVELENGTH 800-700 mm
POWER <1mW-CLASS IN LASER
PRODUCT, COMPLIES WITH 21
CFR CHAPTER 1, SUBCHAPTER J.
LASER RADIATION-
CLASS 2 LASER PRODUCT,
CONFORMS TO IEC825-1:1993
MADE IN TAIWAN
OS541
Infrared Thermometer

Summary of the content on the page No. 2

® OMEGAnet On-Line Service Internet e-mail www.omega.com info@omega.com Servicing North America: USA: One Omega Drive, Box 4047 ISO 9001 Certified Stamford CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: ® USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA ® Customer Service: 1-800-622-2378 / 1-

Summary of the content on the page No. 3

CONTENT Page I. SAFETY INFORMATION --------------------- 2 II. CAUTIONS --------------------------------------- 2 III. GENERAL SPECIFICATION ---------------- 3 IV. NAME AND FUNCTION ---------------------- 4 V. OPERATION INSTRUCTIONS: Measuring Trigger ---------------------------- 5 Distance to Spot Ratio (D/S) -------------- 5 Emissivity -------------------------------------- 5 Maintenance -----------------------------------

Summary of the content on the page No. 4

Infrared Recorder I. SAFETY INFORMATION • Read the following safety information carefully before attempting to operate or service the meter. • Only qualified personnel should perform repairs or servicing not covered in this manual. • Periodically wipe the case with a dry cloth. Do not use abrasives or solvents on this instrument. • Safety symbols: Dangerous, refer to this manual before using the meter. Apply with European CE. This instrument conforms to the following standar

Summary of the content on the page No. 5

Infrared Recorder • Away from electrical welders, induction heaters and EMF sources. • When using this thermometer under large or abrupt ambient temperature changes, allow 15 minutes for unit to stabilize before use. • Do not keep this thermometer in the environment of high temperature for a long time. • Keep away from dusty environment, and keep in carry case after operation to avoid contamination of optical lenses. III. GENERAL SPECIFICATION Display: 4 digit LCD Display Illumin

Summary of the content on the page No. 6

Infrared Recorder IV. NAME AND FUNCTION 1 SCAN CAUTION 7 2 LASER RADIATION - DO NOT STARE INTO BEAM OUTPUT < 1mW AT 630 670mm CLASS II LASER PRODUCT 5 OPEN LASER ON C 3 4 OFF F 6 1 2 Laser dot/circle switch Infrared sensor aperture 4 3 Laser on/off switch °C/°F switch 5 6 Measuring Trigger Battery cover 7 LCD display LCD Display Scan indication Laser on indication Data Hold indication SCAN Low battery HOLD Temperature unit indication Digital value indication 4

Summary of the content on the page No. 7

Infrared Recorder V. OPERATION INSTRUCTIONS • Measuring Trigger To measure a temperature, point the unit at an object and pull the trigger. Be sure to consider distance-to-spot size ratio and field of view. The laser is used for aiming the target for reference. When the laser is on, you can switch between laser dot and circle by moving a lever in front of optics. Laser dot is an indication of the center of the field of view. Laser circle is an indication of the perimeter of the field

Summary of the content on the page No. 8

Infrared Recorder • Emissivity Emissivity is a term used to describe the energy-emitting characteristics of materials. The higher of this value means the more capability of radiation emittance the materials has. Most organic materials and painted or oxidized surfaces have an emissivity of 0.98. Metal surfaces or shiny materials has a lower emissivity and give inaccurate readings. Please note this during applications. • Maintenance Blow off loose particles using a lens blow. Gently b

Summary of the content on the page No. 9

WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product. If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department w

Summary of the content on the page No. 10

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! Shop online at www.omega.com TEMPERATURE   Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies   Wire: Thermocouple, RTD & Thermistor   Calibrators & Ice Point References   Recorders, Controllers & Process Monitors   Infrared Pyrometers PRESSURE, STRAIN AND FORCE   Transducers & Strain Gages   Load Cells & Pressure Gages   Displacement Transducers   Instrumentation & Ac


Alternative user manuals
# User manual Category Download
1 Omega 25 User manual Thermometer 1
2 Omega A12P User manual Thermometer 0
3 Omega CL24 User manual Thermometer 4
4 Omega CL25 User manual Thermometer 5
5 Omega 27 User manual Thermometer 0
6 Omega CL27 User manual Thermometer 6
7 Omega CL23A User manual Thermometer 30
8 Omega CL26 User manual Thermometer 4
9 Omega 26 User manual Thermometer 0
10 Omega CL3512A User manual Thermometer 19
11 Omega DP1001M User manual Thermometer 0
12 Omega DP751 User manual Thermometer 0
13 Omega DP119-RTD User manual Thermometer 0
14 Omega DPG110/120 User manual Thermometer 1
15 Omega HH370 User manual Thermometer 1
16 A&D DT-103 User manual Thermometer 40
17 A&D DT-102 User manual Thermometer 24
18 A&D UT-302 User manual Thermometer 15
19 Acu-Rite 416 User manual Thermometer 7
20 Acu-Rite #00609SBDIA1 User manual Thermometer 3