Omega HH501DK user manual

User manual for the device Omega HH501DK

Device: Omega HH501DK
Category: Thermometer
Manufacturer: Omega
Size: 0.18 MB
Added : 6/16/2014
Number of pages: 11
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Omega HH501DK. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Omega HH501DK.

For your convenience

If looking through the Omega HH501DK user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Omega HH501DK on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Omega HH501DK to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Omega HH501DK User manual - Online PDF
Advertisement
« Page 1 of 11 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Omega HH501DK but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Omega HH501DK. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

OMEGA
HH501DK
Digital Thermometer

Summary of the content on the page No. 2

TM omega.com SM OMEGAnet On-Line Service Internet e-mail http://www.omega.com info@omega.com Servicing North America: USA: ISO 9001 Certified Canada: One Omega Drive, Box 4047 976 Bergar Stamford, CT 06907-0047 Laval (Quebec) H7L5A1 Tel: (203) 359-1660 Tel: (514) 856-6928 FAX: (203)359-7700 FAX: (514) 856-6886 e-mail: info@omega.com e-mail: info@omega.com For immediate technical or application assistance: USA and Canada: Mexico and Latin America: SM SM Sales Service: 1-800-826-6342 / 1-800-TC-OM

Summary of the content on the page No. 3

INTRODUCTION This instrument is a portable 3½ digit, compact-sized digital thermometer designed to use external K-type thermocouple as temperature sensor. Tem- perature indication follows Reference Temperature/Voltage Tables (N.I.S.T. Monograph 175 Revised to ITS-90) for K-type thermocouples. SAFETY INFORMATION It is recommended that you read the safety and operation instructions before using the thermometer. WARNING To avoid electrical shock, do not use this instrument when voltages at the mea

Summary of the content on the page No. 4

SPECIFICATIONS ELECTRICAL Temperature Scale: Celsius or Fahrenheit user-selectable Measurement Range: -50°C to 1300°C, (-58°F to 2000°F) Resolution: 1°C or 1°F, 0.1°C or 0.1°F Accuracy: Accuracy is specified for operating temperatures over the range of 18°C to 28°C (64°F to 82°F), for 1 year, not including thermocouple error. ±(0.3% rdg + 1°C) -50°C to 1000°C ±(0.5% rdg + 1°C) 1000°C to 1300°C ±(0.3% rdg + 2°F) -58°F to 2000°F Temperature Coefficient: 0.1 times the applicable accuracy specificat

Summary of the content on the page No. 5

ENVIRONMENTAL Ambient Operating Ranges: 0°C to 50°C (32°F to 122°F) <80% R.H. Storage Temperature: -20°C to 60°C (-4°F to 140°F) <70% R.H. GENERAL Display: 3½ digit liquid crystal display (LCD) with maximum reading of 1999. Battery: Standard 9V battery. Battery Life: 200 hours typical with carbon zinc battery. Dimensions: 192mm(H) x 91mm(W) x 52.5mm(D). Weight: 365g. 3

Summary of the content on the page No. 6

OPERATING INSTRUCTIONS Selecting the Temperature Scale Readings are displayed in either degrees Celsius(°C) or degrees Fahrenheit(°F). To change the temperature scale, press the "°C" or "°F"key. Selecting the Display Resolution The thermometer allows two choices of resolution: High resolution: 0.1°C or 0.1°F Low resolution: 1.0°C or 1.0°F To select the alternate display resolution, press the corresponding "0.1°/1°" key. HOLD Mode Press " HOLD" button to toggle in and out of Hold mode, In the Hol

Summary of the content on the page No. 7

MAX Mode Pressing the Max key to enter the MAX mode. The thermometer then records and updates the maximum absolute values and the MAX annunciator appears on the display. Pressing the MAX key again to exit the MAX recording mode. In the MAX mode, press HOLD key to stop the recording, press HOLD again to resume recording. T1,T2,T3,T4, T1-T2,T1-T3,T1-T4 Temperature Measurement 1. The function switch indicates which input is selected for display; T1 thermocouple, T2 thermocouple,T3 thermocoupleor, T

Summary of the content on the page No. 8

MAINTENANCE WARNING To avoid possible electrical shock, disconnect the thermocouple connectors from the thermometer before removing the cover. Battery Replacement Power is supplied by a 9 volt "transistor" battery. (NEDA 1604, IEC 6F22). The " " appears on the LCD display when replacement is needed. To replace the battery, remove the two screws from the back of the meter and lift off the battery cover. Remove the battery from battery contacts. 6

Summary of the content on the page No. 9

HH501DK CALIBRATION PROCEDURE Note: The following calibration procedure should perform only by qualified technicians who have access to the items as following. Equipment: The class of calibrator had better 10 times greater than the measured meter. Temperature Calibration Insert the K type thermocouple to the female connector, and the other side of this probe to Temperature Calibrator and connect output to the voltage meter. We must allow the K type to stabilize for at least 1 minute and make su

Summary of the content on the page No. 10

WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA's customers receive maximum coverage on each product.If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA's Customer Service Departme

Summary of the content on the page No. 11

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA...Of Course! TEMPERATURE DATA ACQUISITION þ Thermocouple, RTD & Thermistor þ Data Acquisition & Probes, Connectors, Panels & Assemblies Engineering Software þ Wire: Thermocouple, RTD & Thermistor þ Communications-Based þ Calibrators & Ice Point References Acquisition Systems þ Recorders, Controllers & Process Monitors þ Plug-in Cards for Apple, IBM þ Infrared Pyrometers & Compatibles þ Datalogging Systems PRESSURE/STRAI


Alternative user manuals
# User manual Category Download
1 Omega 25 User manual Thermometer 1
2 Omega A12P User manual Thermometer 0
3 Omega CL24 User manual Thermometer 4
4 Omega CL25 User manual Thermometer 5
5 Omega 27 User manual Thermometer 0
6 Omega CL27 User manual Thermometer 6
7 Omega CL23A User manual Thermometer 30
8 Omega CL26 User manual Thermometer 4
9 Omega 26 User manual Thermometer 0
10 Omega CL3512A User manual Thermometer 19
11 Omega DP1001M User manual Thermometer 0
12 Omega DP751 User manual Thermometer 0
13 Omega DP119-RTD User manual Thermometer 0
14 Omega DPG110/120 User manual Thermometer 1
15 Omega HH370 User manual Thermometer 1
16 A&D DT-103 User manual Thermometer 40
17 A&D DT-102 User manual Thermometer 24
18 A&D UT-302 User manual Thermometer 15
19 Acu-Rite 416 User manual Thermometer 7
20 Acu-Rite #00609SBDIA1 User manual Thermometer 3