Omega CL3512A user manual

User manual for the device Omega CL3512A

Device: Omega CL3512A
Category: Thermometer
Manufacturer: Omega
Size: 0.33 MB
Added : 6/16/2014
Number of pages: 10
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Omega CL3512A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Omega CL3512A.

For your convenience

If looking through the Omega CL3512A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Omega CL3512A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Omega CL3512A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Omega CL3512A User manual - Online PDF
Advertisement
« Page 1 of 10 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Omega CL3512A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Omega CL3512A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


#17000-0513-OME1


CL3512A
Digital Thermometer & Calibrator



SM
OMEGAnet On-Line Service Internet e-mail
http://www.omega.com info@omega.com

Servicing North America:
USA: ISO 9001 Certified Canada:
One Omega Drive, Box 4047 976 Bergar
Stamford, CT 06907-0047 Laval (Quebec) H7L5A1
Tel: (203) 359-1660 Tel: (514) 856-6928
FAX: (203)359-7700 FAX: (514) 856-6886
e-mail: info@omega.com e-mail: info@omega.com
For immediate technical or application assistance:
USA and Canada: Mex

Summary of the content on the page No. 2

Table of contents 1.0 Introduction 1.1 Safety Information 1.2 Unpacking 2.0 Operation Procedure 2.1 Unit Drawing 2.2 Description of Buttons and Switches 2.3 Read Mode Procedure 2.4 Source Mode Procedure 3.0 Operator Maintenance 4.0 Specifications 5.0 Calibration Procedure

Summary of the content on the page No. 3

1.0 Introduction ® The OMEGA CL3512A calibrator/thermometer is two meters in one. The CL3512A simulates type J/K/T/E thermocouple signals. Each signal is adjustable by using the coarse and fine dials. The CL3512A can also be used as a dual type J/K/T/E thermocouple input thermometer. Features include a large 3½ digit display with backlighting and display selections of HOLD, °C/°F, and0.1/1°. The source mode of the CL3512A simulates the thermocouple output to check the operation of a th

Summary of the content on the page No. 4

2.0 Operation Procedure 2.1 Drawing of Unit Actual Dimensions: 195mm(H) x 92mm(W) x 53mm(D) 3 2.2 Descriptions of Buttons and Switches / Buttons Temperature is displayed in either degrees Celsius(°C) or degrees Fahrenheit(°F). When the thermometer is turned on, it is set to the temperature scale that was in use when the thermometer was last turned off. To change the temperature scale, press the °C or °F key. Button Press “ ” button to toggle the on and off backlight.

Summary of the content on the page No. 5

/ / Input Selections The input selection indicates which input is selected; T1 thermocouple, T2 thermocouple or the difference between the two thermocouples (T1-T2). When the thermometer is turned on, it is set to the temperature input that was in use when the thermometer was last turned off. Selector Switch The circular selector switch is used to turn the unit off () or to select Reading Mode (Input) or Simulation Mode (Output). There are nine selector switch positions under output

Summary of the content on the page No. 6

2.4 Source Mode Procedure (Calibration Simulation) 1. Turn CL3512A on by turning selector switch to any one of the output selector positions. 2. Press T1 button. 3. Select thermocouple type (J, K, T or E) using type button. Select °C or °F using °C or °F buttons. 4. Plug proper type of thermocouple wire into either one of the two output connectors. (SMP male connector required) 5. Attach the other end of the thermocouple wire to the instrument being tested/calibrated. 6. Move the out

Summary of the content on the page No. 7

3.0 Operator Maintenance WARNING To avoid possible electrical shock, disconnect the thermocouple connectors from the thermometer before removing the cover. Battery Replacement Power is supplied by a 9 volt “transistor” battery. The “ ” appears on the LCD display when replacement is needed. To replace the battery, remove the two screws from the back of the meter and lift off the battery cover. Remove the battery from battery contacts. 9 4.0 Specifications ELECTRICAL Temperature Sca

Summary of the content on the page No. 8

GENERAL Display: 3½ digit liquid crystal display (LCD) with a maximum reading of1999. Polarity: Automatic, positive implied, negative polarity indication. Overrange: -OL is displayed. Zero: Automatic. ” is displayed when the battery voltage Low battery indication: The “ drops below the operating level. Measurement rate: 1 times/second. Accuracy: Stated accuracy at 23°C±5°C, <75% R.H. Dimensions: 195mm(H) x 92mm(W) x 53mm(D). Weight: approx. 9 oz. (250g) including battery. Input Conn

Summary of the content on the page No. 9

13

Summary of the content on the page No. 10

WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA's customers receive maximum coverage on each product. If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA's Customer Servic


Alternative user manuals
# User manual Category Download
1 Omega 25 User manual Thermometer 1
2 Omega A12P User manual Thermometer 0
3 Omega CL24 User manual Thermometer 4
4 Omega CL25 User manual Thermometer 5
5 Omega 27 User manual Thermometer 0
6 Omega CL27 User manual Thermometer 6
7 Omega CL23A User manual Thermometer 30
8 Omega CL26 User manual Thermometer 4
9 Omega 26 User manual Thermometer 0
10 Omega DP1001M User manual Thermometer 0
11 Omega DP751 User manual Thermometer 0
12 Omega DP119-RTD User manual Thermometer 0
13 Omega DPG110/120 User manual Thermometer 1
14 Omega HH370 User manual Thermometer 1
15 Omega HH501DK User manual Thermometer 0
16 A&D DT-103 User manual Thermometer 40
17 A&D DT-102 User manual Thermometer 24
18 A&D UT-302 User manual Thermometer 15
19 Acu-Rite 416 User manual Thermometer 7
20 Acu-Rite #00609SBDIA1 User manual Thermometer 3