Fluke 65 user manual

User manual for the device Fluke 65

Device: Fluke 65
Category: Thermometer
Manufacturer: Fluke
Size: 0.06 MB
Added : 10/21/2014
Number of pages: 8
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Fluke 65. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Fluke 65.

For your convenience

If looking through the Fluke 65 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Fluke 65 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Fluke 65 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Fluke 65 User manual - Online PDF
Advertisement
« Page 1 of 8 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Fluke 65 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Fluke 65. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
Model 65
Infrared Thermometer
Calibration Information
Introduction
This calibration information for the Fluke 65 Infrared Thermometer (also referred to as “the UUT”) provides
the following information:
• Safety information
• Specifications
• Basic maintenance
• Equipment required for performance tests and calibration
• Performance test procedures
• Calibration adjustment procedures
• List of replaceable parts
For complete operating instructions, refer to the Model 65 Infrared Thermometer Instr

Summary of the content on the page No. 2

Model 65 Calibration Information Safety Information A Warning To avoid possible personal injury: • The information provided in this manual is for the use of qualified personnel only. Do not perform the verification tests or calibration procedures described in this manual unless you are qualified to do so. • Performance of procedures other than those specified herein may result in hazardous light exposure. • Do not stare into the laser beam or direct it toward the eyes. Caution To avoid possible

Summary of the content on the page No. 3

Specifications Specifications Measurement Range - 40 °C to +500°C (- 40°F to +932 °F) Operating Temperature (Ambient) 0 °C to +50 °C (+32 °F to +122 °F) Storage Temperature - 20 °C to +70°C (- 4 °F to +158 °F), without battery Display Resolution Below 200 °: 0.1° Above 200°: 1° Measurement Accuracy Below 0°C: ±5 °C (32 °F: ±9°F) Above 0 °C: ±2 °C (32 °F: ±4°F) Above 100 °C: ±2 % of reading [Ambient: 25 °C ±3°C (77°F ±5 °F)] Temperature Coefficient > 400 °C (752 °F): ±

Summary of the content on the page No. 4

Model 65 Calibration Information Maintenance Installing the Batteries Remove the holster to access the battery door. Figure 1 shows how to replace the batteries. Caution • Match the + and - polarities of the battery with the battery case. • Do not attempt to recharge the batteries. • Do not throw batteries into a fire. • Follow local laws or regulations when disposing of batteries. The B indicates battery life remaining. Replace both batteries when I starts blinking. acd02f.eps Figure 1. Replaci

Summary of the content on the page No. 5

Required Equipment Required Equipment Table 1 shows the equipment required for the performance tests and calibration adjustments. Table 1. Required Equipment Equipment Minimum Specifications Recommended Model Blackbody Calibration Source Temperature range: Ambient to 400 °C Mikron M315 Blackbody Calibration Source with 0.95 Minimum aperture diameter: 76 mm (3.0 in) emissivity error correction table Maximum temperature: ≥ 400 °C Accuracy: ±0.5 °C to 100 °C ±0.5 % of reading above 100 °C Settin

Summary of the content on the page No. 6

Model 65 Calibration Information Table 2. Performance Test Values 1, 2 Temperature at 0.95 Emissivity UUT Reading Limits Room temperature Room temperature ±2 °C (±3.6 °F) 200 °C (392 °F) 196 °C to 204 °C (384.8 °F to 399.2 °F) 300 °C (572 °F) 294 °C to 306 °C (561.2 °F to 582.8 °F) 400 °C (752 °F) 392 °C to 408 °C (737.6 °F to 766.4 °F) 1. Room temperature must be 25 °C ±3 °C (77 °F ±5 °F). 2. Limits given are ±2 % of temperature at 0.95 emissivity. Calibration Adjustments The Model 65 Infrared

Summary of the content on the page No. 7

Calibration Adjustments Room temperature calibration mode High temperature calibration mode MIN MAX °C °F Factory Calibration mode. Caution Do not change the factory calibration setting End calibration mode Press to exit calibration mode acd01f.eps Figure 2. Calibration Menu 7

Summary of the content on the page No. 8

Model 65 Calibration Information 8. Press D to enter the high-temperature adjustment mode (display shows 2_H), as shown in Figure 2. 9. Press G. The default high-temperature appears on the UUT display. 10. Aim the UUT at the blackbody target; then use F or D to adjust the UUT reading down or up, respectively, to read 350 °C. 11. When you have set the UUT reading to 350 °C, press G. The UUT display flashes briefly, then returns to the calibration selection mode. Note If the high temperature you e


Alternative user manuals
# User manual Category Download
1 Fluke 114 User manual Thermometer 24
2 Fluke 117 User manual Thermometer 414
3 Fluke 115 User manual Thermometer 126
4 Fluke 1522 User manual Thermometer 16
5 Fluke 1521 User manual Thermometer 33
6 Fluke 1529 Chub-E4 User manual Thermometer 39
7 Fluke 116 User manual Thermometer 34
8 Fluke 1523 User manual Thermometer 12
9 Fluke 1594A User manual Thermometer 4
10 Fluke 1524 User manual Thermometer 22
11 Fluke 1595A User manual Thermometer 5
12 Fluke 2180A User manual Thermometer 6
13 Fluke 233 User manual Thermometer 48
14 Fluke 2190A User manual Thermometer 15
15 Fluke 50S User manual Thermometer 20
16 A&D DT-103 User manual Thermometer 40
17 A&D DT-102 User manual Thermometer 24
18 A&D UT-302 User manual Thermometer 15
19 Acu-Rite 416 User manual Thermometer 7
20 Acu-Rite #00609SBDIA1 User manual Thermometer 3