Fluke 50S user manual

User manual for the device Fluke 50S

Device: Fluke 50S
Category: Thermometer
Manufacturer: Fluke
Size: 0.16 MB
Added : 7/25/2014
Number of pages: 14
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Fluke 50S. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Fluke 50S.

For your convenience

If looking through the Fluke 50S user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Fluke 50S on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Fluke 50S to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Fluke 50S User manual - Online PDF
Advertisement
« Page 1 of 14 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Fluke 50S but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Fluke 50S. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

50S & 50D
Thermometer
Calibration Information
WWarning
These service instructions are for use by qualified personnel only. To avoid
electric shock, do not perform any servicing unless you are qualified to do so.
Introduction
This document contains specifications, general maintenance information, performance tests, calibration
procedures, and a list of user replaceable parts for the Fluke 50S and 50D Thermometers, hereafter referred
to as “the thermometer”.
Service
To contact Fluke, order parts,

Summary of the content on the page No. 2

50S & 50D Thermometer Calibration Information International Symbols Table 1 identifies the international electrical symbols used in this document. Table 1. International Electrical Symbols Used in this Document Low Battery Important information N Complies with relevant Canadian Complies with European Union directives Standards Association directives Underwriters Laboratories, Inc. Precautions and Safety Information Use the thermometer only in the ways specified in the 50S & 50D Users Manual, par

Summary of the content on the page No. 3

Specifications Specifications General Weight 280 g (10 oz) Dimensions 2.8 cm × 7.5 cm × 16.6 cm (without holster) (1.1 in × 3 in × 6.6 in) Battery Standard 9 V battery (NEDA 1604, 6F22, or 006P) Protection Class III as defined in IEC 348, Safety Requirements for Electronic Apparatus Environmental o o o o Operating Temperature 0 C to +50 C (+32 F to +122 F) o o o o Storage Temperature - 40 C to +60 C (- 40 F to +140 F) o o o o 0 % to 90 %: 0 C to 35 C (+32 F to +95 F) o o o o Humidity 0 % to 70

Summary of the content on the page No. 4

50S & 50D Thermometer Calibration Information Clean the thermometer case with a mild detergent and water. The pca may be washed with isopropyl alcohol or deionozed water and a soft brush. Dry the pca with clean o dry air at low pressure, then bake it at 50 C for 24 hours. Disassembly/Reassembly Thermometer disassembly is necessary to replace the battery and some interior parts (see “Replaceable Parts”, later in this document). Refer to Figure 1 when disassembling and reassembling the thermometer

Summary of the content on the page No. 5

Basic Maintenance Changing the Battery WWarning • Replace the battery as soon as the low battery indicator (N) appears. The possibility of false readings increases when the battery is not fully charged. False readings can lead to personal injury. • To avoid electrical shock, disconnect the thermocouple(s) before opening the case. Caution • Do not attempt to recharge the battery. • To prevent explosion, do not dispose of the battery in fire. • Follow local laws or regulations when disposing of ba

Summary of the content on the page No. 6

50S & 50D Thermometer Calibration Information Required Test Equipment Table 2 lists the required test equipment needed to perform the performance test and calibration procedures for the 50S and 50D thermometers. If the required equipment is not available, instruments with equivalent specifications may be used. Table 2. Required Test Equipment Test Equipment Required Characteristics Recommended Model Fluke 87 Series IV Digital DMM DC Voltage Accuracy: 0.5% Multimeter o Temperature Probe Accuracy:

Summary of the content on the page No. 7

Performance Tests 50S Display 50D Display J K J K - + - + HOLD MIN MAX HOLD REC F C F C T1 T2 T1-T2 zf03f.eps Figure 3. Display Segments Wide Range Performance Test Procedure This test verifies the instrument specifications. If the instrument fails this test, perform the calibration procedure. If the unit continutes to fail, it should be taken to a Fluke service center. Ice Bath Construction To begin the wide range performance test procedure, first construct an ice bath using the following steps

Summary of the content on the page No. 8

50S & 50D Thermometer Calibration Information 50S or 50D Thermocouple wire Thermometer + _ Ice bath 5520A Copper wire zf05f.eps Figure 4. Ice Bath Equipment Connections Ice Bath Test Use the following procedure to test the thermometer. This test should be conducted on both thermocouple inputs of the 50D. 1. Connect the equipment as shown in Figure 4. 2. Insert the Mercury Thermometer to the same depth as the thermocouple wires and verify that the ice o o bath temperature is 0.0 C ±

Summary of the content on the page No. 9

Calibration Table 3. Performance Test Values Thermocouple Input Voltage Display Reading o o Type (mV DC) C F K -5.587 -182.0 ±(0.9) -295.6 ±(1.6) K -3.211 -89.0 ±(0.8) -128.2 ±(1.4) K 21.919 530.0 ±(1.2) 986.0 ±(2.3) K 54.297 1355.0 ±(2.1) 2471.0 ±(3.8) J -7.824 -197.0 ±(1.0) -322.6 ±(1.7) J 13.997 258.0 ±(1.1) 496.4 ±(1.9) J 39.442 705.0 ±(1.5) 1301.0 ±(2.7) Calibration When calibrating the thermometer, refer to Figure 5 for the proper setup connections and Figure 6 for adjustment locations. Ca

Summary of the content on the page No. 10

50S & 50D Thermometer Calibration Information position until the display is locked in self-test (all LCD segments on). This thermometer is now in the Reference Junction Sensor calibration mode. Shorting out the VIEW switch grid turns off a filter so that the reading stabilizes immediately. 13. Using the 80T-150U and the Fluke 87 Series IV Digital Multimeter (DMM), measure the reference junction transistor temperature by placing the 80T-150U probe tip against Q1, located in the middle hole of the

Summary of the content on the page No. 11

Calibration FLUKE 52-1601 zf09f.eps Figure 6. A1 Main PCA Adjustments Optimizing Thermometer Performance in the Negative Temperature Range Perform the following steps to optimize the thermometer performance in the negative temperature range: 1. Put the thermometer in normal operating mode. Normal operation can be achieved by turning the thermometer OFF and then ON. No other thermometer buttons should be pressed during the power cycle operation. 2. Insert a known good thermocouple in an ice bath

Summary of the content on the page No. 12

50S & 50D Thermometer Calibration Information 5. Allow the system to stabilize, then adjust T1 or T2 offset adjustments for a temperature display equal to the reading of the lag bath reference thermometer. 6. Calibration of the thermometers is complete. Disconnect all test equipment from the instrument. 50S or 50D Thermometer _ + Thermocouple wire Mercury thermometer (0.02°C resolution) Lag bath (room temperature water) Immersed to approximately same depth zf06f.eps Figure 7. Room Temperatu

Summary of the content on the page No. 13

Replaceable Parts Replaceable Parts Refer to Table 4 for all replacement part numbers and Figure 8 for part locations. Unless specified in the “Model Number” column, all parts are for all units. To order replaceable parts, see the “Service Centers” section of this manual. Table 4. 50S and 50D Replaceable Parts Fluke Item Part Model Number Qty. Number Description Number 1 778191 MAIN PCA 50S 1 1 778209 MAIN PCA 50D 2 1 696534 BATTERY, PRIMARY, 9V, 0-15MA All 3 4 832246 SCREW, PH, P, AM THD FORM,

Summary of the content on the page No. 14

50S & 50D Thermometer Calibration Information 15 6 9 4 16 2 10 4X 5 1 12 8 7 11 2X 4X 13 3 4X zf08f.eps Figure 8. Exploded View Diagram (Model 50D is Shown) 14


Alternative user manuals
# User manual Category Download
1 Fluke 114 User manual Thermometer 24
2 Fluke 117 User manual Thermometer 414
3 Fluke 115 User manual Thermometer 126
4 Fluke 1522 User manual Thermometer 16
5 Fluke 1521 User manual Thermometer 33
6 Fluke 1529 Chub-E4 User manual Thermometer 39
7 Fluke 116 User manual Thermometer 34
8 Fluke 1523 User manual Thermometer 12
9 Fluke 1594A User manual Thermometer 4
10 Fluke 1524 User manual Thermometer 22
11 Fluke 1595A User manual Thermometer 5
12 Fluke 2180A User manual Thermometer 6
13 Fluke 233 User manual Thermometer 48
14 Fluke 2190A User manual Thermometer 15
15 Fluke 53 & 54 Series User manual Thermometer 8
16 A&D DT-103 User manual Thermometer 40
17 A&D DT-102 User manual Thermometer 24
18 A&D UT-302 User manual Thermometer 15
19 Acu-Rite 416 User manual Thermometer 7
20 Acu-Rite #00609SBDIA1 User manual Thermometer 3