Fluke 233 user manual

User manual for the device Fluke 233

Device: Fluke 233
Category: Thermometer
Manufacturer: Fluke
Size: 0.68 MB
Added : 7/25/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Fluke 233. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Fluke 233.

For your convenience

If looking through the Fluke 233 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Fluke 233 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Fluke 233 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Fluke 233 User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Fluke 233 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Fluke 233. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


Getting Started Manual
233
True-rms Remote Display Digital Multimeter









PN 3465366
September 2009
© 2009 Fluke Corporation. All rights reserved. Printed in USA. Specifications
are subject to change without notice.
All product names are trademarks of their respective companies.

Summary of the content on the page No. 2

LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for three years from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke’s behalf. To obtain service during the warranty period, contact your nearest Fluke authoriz

Summary of the content on the page No. 3

Introduction The Fluke 233 (hereafter the Meter) is a compact and easy to operate tool for electrical and electronic circuit measurements. XWWarning Read "Safety Information" before you use the Meter. How to Contact Fluke Use one of the telephone numbers below to speak with a Fluke representative: Technical Support USA: 1-800-44-FLUKE (1-800- 443-5853) Calibration/Repair USA: 1-888-99-FLUKE (1-888- 993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-675-200 Japan: +81

Summary of the content on the page No. 4

233 Getting Started Manual XWWarning Safety Information To prevent possible electrical shock or The Meter complies with: personal injury, follow these guidelines: • ISA-82.02.01 • Use this Meter only as specified in this • CAN/CSA C22.2 No. 61010-1-04 manual or the protection can be • ANSI/UL 61010-1:2004 compromised. • EN 61010-1:2001 • Do not use the Meter if it is damaged. • EN 61326-1:2006 Before you use the Meter, examine the • EN 61326-2-2:2006 case. Look for cracks or mi

Summary of the content on the page No. 5

True-rms Remote Display Digital Multimeter Safety Information • Remove the test leads from the Meter • For current measurements, connect the before the battery door on the Meter Meter to the circuit after you remove base is opened. circuit power. Always put the Meter in series with the circuit. • Examine the test leads for damaged insulation or exposed metal. Measure the • Connect the common test lead before test leads for continuity. Replace the live test lead and remove the live test

Summary of the content on the page No. 6

233 Getting Started Manual • Use only specified 1.5-V AA batteries WCaution (three in the Meter base and two in the To prevent damage to the Meter or to the display), correctly installed, for Meter equipment under test, follow these power. guidelines: • Comply with local and national safety • Disconnect circuit power and discharge requirements when in hazardous all high-voltage capacitors before you do locations. diode tests or measure resistance, • Only use test leads that have

Summary of the content on the page No. 7

True-rms Remote Display Digital Multimeter Safety Information Table 1. Electrical Symbols AC (Alternating Current) Earth ground B J F DC (Direct Current) I Fuse X Hazardous voltage P Conforms to European Union directives. Risk of Danger. Important information. Conforms to relevant Canadian Standards W ) See Manual. Association directives.  Battery. Low battery when shown. T Double insulated R Continuity test or continuity beeper tone. E Capacitance IEC Measurement Category IV IE

Summary of the content on the page No. 8

233 Getting Started Manual Features See Tables 3 through 4 for a list of Meter features with a short feature description. Table 2. Display 4 2 3 1 5 14 13 6 12 meter Auto RangeManual Range remote 10 7 11 9 8 gcc101.eps No. Symbol Indication 1  MIN MAX AVG mode on. 2 MAX MIN AVG Maximum, minimum, or average measurement shown. 3  Display hold on. Display freezes the measurement. 6

Summary of the content on the page No. 9

True-rms Remote Display Digital Multimeter Features Table 2. Display (cont.) No. Symbol Indication 4  Radio connection indicator. °C, °F 5 degrees Celsius, degrees Fahrenheit 6 A amperes (amps) V, mV volts, millivolts μF, nF microfarad, nanofarad DC AC Direct current or alternating current. Ω, MΩ, kΩ ohm, megohm, kilohm Hz, kHz hertz, kilohertz 7 remote  Battery low warning for the display module. 8 Manual Range Manual range set. 9 Auto Range Auto range set. 10 meter

Summary of the content on the page No. 10

233 Getting Started Manual Table 3. Inputs 1 3 2 gcc110.eps No. Terminal Description Input for 0 A to 10.00 A current measurements. 1 A Common terminal for all measurements. 2 COM Input for voltage, continuity, resistance, diode, capacitance, temperature, and frequency 3  measurements. 8

Summary of the content on the page No. 11

True-rms Remote Display Digital Multimeter Features Table 4. Function Switch Positions Switch Description Position AC voltage from 0.06 to 1000 V.  Frequency from 5 Hz to 50 kHz. Hz (button)  DC voltage from 0.001 V to 1000 V.  AC voltage from 6.0 to 600.0 mV, dc-coupled. DC voltage from 0.1 to 600.0 mV. Ohms from 0.1 Ω to 40 MΩ. e Continuity beeper turns on at <20 Ω and turns off at >250 Ω. Farads from 1 nF to 9999 μF.  Diode Test. OL shows in the display when the input

Summary of the content on the page No. 12

233 Getting Started Manual Error Messages Table 5 contains possible error messages and the steps to clear the error. Table 5. Error Messages Error Messages    Display-module batteries must be replaced before the Meter will operate.    Meter-base batteries must be replaced before the Meter will operate.   Calibration necessary. Meter calibration is necessary before the Meter will operate.   Internal error. The Meter must be repaired before it will operat

Summary of the content on the page No. 13

True-rms Remote Display Digital Multimeter Remote Operation Remote Operation 1 1 2 2 gcc114.eps gcc115.eps Figure 1. Display Module Separation Figure 2. Dock Display Module with Meter Base 11

Summary of the content on the page No. 14

233 Getting Started Manual Fuse Test Battery Replacement 2 Good fuse: 0.0 Ω to 0.5 Ω Replace fuse: OL 3 gcc111.eps Figure 4. Display-Module Battery Removal gcc105.eps Figure 3. Fuse Test 12

Summary of the content on the page No. 15

True-rms Remote Display Digital Multimeter Battery Replacement 1 2 4 3 gcc112.eps Figure 5. Meter Base Battery Replacement 13

Summary of the content on the page No. 16

233 Getting Started Manual General Specifications Maximum voltage between any terminal and earth ground ........................................... 1000 V rms W Fuse for A inputs ..................................................... 11 A, 1000 V 17000A interrupt rating Fuse Altitude Operating .................................................................... 2,000 meters Storage ....................................................................... 12,000 meters Temperature Operati


Alternative user manuals
# User manual Category Download
1 Fluke 114 User manual Thermometer 24
2 Fluke 117 User manual Thermometer 414
3 Fluke 115 User manual Thermometer 126
4 Fluke 1522 User manual Thermometer 16
5 Fluke 1521 User manual Thermometer 33
6 Fluke 1529 Chub-E4 User manual Thermometer 39
7 Fluke 116 User manual Thermometer 34
8 Fluke 1523 User manual Thermometer 12
9 Fluke 1594A User manual Thermometer 4
10 Fluke 1524 User manual Thermometer 22
11 Fluke 1595A User manual Thermometer 5
12 Fluke 2180A User manual Thermometer 6
13 Fluke 2190A User manual Thermometer 15
14 Fluke 50S User manual Thermometer 20
15 Fluke 53 & 54 Series User manual Thermometer 8
16 A&D DT-103 User manual Thermometer 40
17 A&D DT-102 User manual Thermometer 24
18 A&D UT-302 User manual Thermometer 15
19 Acu-Rite 416 User manual Thermometer 7
20 Acu-Rite #00609SBDIA1 User manual Thermometer 3