Fluke 1595A user manual

User manual for the device Fluke 1595A

Device: Fluke 1595A
Category: Thermometer
Manufacturer: Fluke
Size: 3.89 MB
Added : 7/25/2014
Number of pages: 130
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Fluke 1595A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Fluke 1595A.

For your convenience

If looking through the Fluke 1595A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Fluke 1595A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Fluke 1595A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Fluke 1595A User manual - Online PDF
Advertisement
« Page 1 of 130 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Fluke 1595A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Fluke 1595A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

1594A/1595A
Super-Thermometer
Technical Guide
159X____tgeng0000

Summary of the content on the page No. 2

Limited Warranty & Limitation of Liability Each product from Fluke Corporation (“Fluke”) is warranted to be free from defects in material and work- manship under normal use and service. The warranty period is one year(s) for the thermometer. The warranty period begins on the date of the shipment. Parts, product repairs, and services are warranted for 90 days. The warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, dispo

Summary of the content on the page No. 3

Table of Contents 1 Before You Start .................................................................................... 1 1.1 Symbols Used ............................................................................................................1 1.2 Safety Information ......................................................................................................1 1.2.1 WARNINGS .......................................................................................................

Summary of the content on the page No. 4

1594A/1595A Super-Thermometer 4.3.5 Earth Ground Connection ...............................................................................................22 5 Menus and Screens ............................................................................ 23 5.1 Introduction ..............................................................................................................23 5.2 Changing Settings ........................................................................................

Summary of the content on the page No. 5

6.2 User Settings Screen ...............................................................................................57 6.3 Connecting a Probe or Resistor ...............................................................................58 7 Making Measurements ....................................................................... 61 7.1 Introduction ..............................................................................................................61 7.2 Measuring a Temperature P

Summary of the content on the page No. 6

1594A/1595A Super-Thermometer 8.7.3.24 CALC:DELT:DATA? ...........................................................................................................80 8.7.3.25 CALC:DELT:MODE OFFS|CHAN .............................................................................................80 8.7.3.26 CALC:DELT:OFFS .....................................................................................................80 8.7.3.27 CALC:TYPE TEMP|RES|RAT .............................

Summary of the content on the page No. 7

8.7.3.80 SENS:APER[:DISP]

Summary of the content on the page No. 8

1594A/1595A Super-Thermometer 8.7.3.136 TEST:LIN[:STAT]? ..................................................................................................................101 8.7.3.137 TEST:LIN:TIME? ....................................................................................................................101 8.7.3.138 TEST:LIN:TOL? ...............................................................................................................102 8.7.3.139 TEST:SYST:ABOR ...........

Summary of the content on the page No. 9

Figures Figure 1 PEM (Power Entry Module) .................................................................................16 Figure 2 Front view ...........................................................................................................17 Figure 3 Front Panel Display .............................................................................................19 Figure 4 Rear view ................................................................................................

Summary of the content on the page No. 10

1594A/1595A Super-Thermometer Tables Table 1 Symbols ..................................................................................................................1 Table 2 Resistance Ratio Accuracy Specifications ............................................................6 Table 3 Resistor Stability Specifications .............................................................................7 Table 4 Absolute Resistance Accuracy Specifications .............................................

Summary of the content on the page No. 11

Before You Start Safety Information 1 Before You Start 1.1 Symbols Used Table 1 lists the symbols that may be used on the instrument or in this manual and the meaning of each symbol. Table 1 Symbols Symbol Description Symbol Description AC (Alternating Current) PE Ground AC-DC Hot Surface (Burn Hazard) Read the User’s Guide Battery (Important Information) Complies with European Union Off directives DC On Double Insulated Standby Indication Canadian Standards Electric Shock Association Fuse C

Summary of the content on the page No. 12

1594A/1595A Super-Thermometer Authorized Service Centers ●● DO NOT connect an AC mains supply that does not match the voltage setting on the back of the unit. ●● DO NOT use this instrument in combination with any probe ( PRT or thermistor) to measure the temperature or resistance of any device where the probe might come in contact with a conductor that is electrically energized. Severe electric shock, personal injury, or death may occur. ●● DO NOT position this instrument in a manner where it

Summary of the content on the page No. 13

Before You Start Authorized Service Centers Fluke South East Asia Pte Ltd. Fluke ASEAN Regional Office Service Center 60 Alexandra Terrace #03-16 The Comtech (Lobby D) 118502 SINGAPORE Phone: +65 6799-5588 Telefax: +65 6799-5588 E-mail: antng@singa.fluke.com When contacting these Service Centers for support, please have the following information available: ●● Model Number ●● Serial Number ●● Voltage ●● Complete description of the problem 3

Summary of the content on the page No. 14

Summary of the content on the page No. 15

Introduction and Specifications Specifications 2 Introduction and Specifications 2.1 Introduction The Fluke family of Hart Super-Thermometers long ago established the standard for easy-to-use, precision temperature measurement instrumentation. Laboratories worldwide have selected the Super-Thermometer not only for the assurance of achieving high-quality results, but also for the innovative features that increase productivity in the lab. The Fluke 1594A and 1595A Hart Super-Thermometers contin

Summary of the content on the page No. 16

1594A/1595A Super-Thermometer Specifications Primary Specifications: the core set of measurement accuracy specifications of the Super-Thermometer. They are guaranteed for performance verification at the 99% confidence level. Ancillary Specifications: additional specifications that help the user understand more of the uncertainties involved in measurement. Since they may be subject to the application and setting in which the Super-Ther- mometer is used, they are not guaranteed for performance v

Summary of the content on the page No. 17

Introduction and Specifications Specifications Table 3 Resistor Stability Specifications Resistor (Rs) Accuracy (ppm of reading), 95 % confidence level 24 hours 30 days 1 W 5 ppm 10 ppm 10 W 0.5 ppm 2 ppm 25 W 0.25 ppm 1 ppm 100 W 0.2 ppm 1 ppm 10 kW 0.25 ppm 1 ppm 2.2.2.3 Absolute Resistance Accuracy Absolute resistance accuracy is the ability of the instrument to measure absolute resistance, Rx, using the internal reference resistors. The following specifications apply using the given refere

Summary of the content on the page No. 18

1594A/1595A Super-Thermometer Specifications Table 5 Measurement Current Accuracy Specifications Current Range Accuracy 99% confidence level, 1-year 0.001 mA to 0.005 mA 0.00005 mA 0.005 mA to 0.02 mA 1 % 0.02 mA to 0.2 mA 0.5 % 0.2 mA to 2 mA 0.2 % 2 mA to 20 mA 0.5 % 2.2.3 Ancillary Specifications 2.2.3.1 Temperature Measurement Noise Temperature measurement noise indicates typical measurement noise in temperature measurements. The speci- fications below are given for averages taken over a per

Summary of the content on the page No. 19

Introduction and Specifications Specifications 2.2.4 General Specifications Table 8 General Specifications Warm-up period 30 minutes Measurement range 0 W to 500 kW Measurement current range 0.001 mA to 20 mA Measurement current reversal interval: Sample period of 1 second or 2 seconds 0.2 second Sample period of 5 second or 10 seconds 1.2 second Standby current range 0.001 mA to 2 mA AC power 100 V to 230 V (± 10 %) 50 or 60 Hz Fuse Rating 2 A – T – 250 V Specified operating temperature 15 °C

Summary of the content on the page No. 20

1594A/1595A Super-Thermometer Specifications When calibrating an SPRT on the ITS-90, the W value is measured at required fixed-point temperatures. T90 This is done by measuring the resistance of the SPRT at a fixed-point temperature followed immediately by measurement of the RTPW. This is repeated for each temperature point. Once again the ratio accuracy of the Super-Thermometer, applied to each measured resistance, determines the accuracy of the resulting W value. T90 2.2.5.3 Example 1: Me


Alternative user manuals
# User manual Category Download
1 Fluke 114 User manual Thermometer 24
2 Fluke 117 User manual Thermometer 414
3 Fluke 115 User manual Thermometer 126
4 Fluke 1522 User manual Thermometer 16
5 Fluke 1521 User manual Thermometer 33
6 Fluke 1529 Chub-E4 User manual Thermometer 39
7 Fluke 116 User manual Thermometer 34
8 Fluke 1523 User manual Thermometer 12
9 Fluke 1594A User manual Thermometer 4
10 Fluke 1524 User manual Thermometer 22
11 Fluke 2180A User manual Thermometer 6
12 Fluke 233 User manual Thermometer 48
13 Fluke 2190A User manual Thermometer 15
14 Fluke 50S User manual Thermometer 20
15 Fluke 53 & 54 Series User manual Thermometer 8
16 A&D DT-103 User manual Thermometer 40
17 A&D DT-102 User manual Thermometer 24
18 A&D UT-302 User manual Thermometer 15
19 Acu-Rite 416 User manual Thermometer 7
20 Acu-Rite #00609SBDIA1 User manual Thermometer 3