Our goal is to provide you with a quick access to the content of the user manual for Fluke 1529 Chub-E4. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Fluke 1529 Chub-E4.

For your convenience

If looking through the Fluke 1529 Chub-E4 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Fluke 1529 Chub-E4 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Fluke 1529 Chub-E4 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Fluke 1529 Chub-E4 User manual - Online PDF
Advertisement
« Page 1 of 154 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Fluke 1529 Chub-E4 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Fluke 1529 Chub-E4. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Hart Scientific
1529
Chub-E4ThermometerReadout
User’sGuide
Rev. 5A2602

Summary of the content on the page No. 2

Fluke Corporation, Hart Scientific Division 799 E. Utah Valley Drive • American Fork, UT 84003-9775 � USA Phone: +1.801.763.1600 � Telefax: +1.801.763.1010 E-mail: support@hartscientific.com www.hartscientific.com Subject to change without notice. � Copyright © 2005 � Printed in USA Rev. 5A2602

Summary of the content on the page No. 3

Table of Contents 1 Before You Start . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 Symbols Used . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.2 Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1.2.1 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1.2.2 Cautions . . . . . . . . . . . . .

Summary of the content on the page No. 4

6.5 DC Power Source . . . . . . . . . . . . . . . . . . . . . . . . . . 25 6.6 Power On Self-Test . . . . . . . . . . . . . . . . . . . . . . . . . 25 6.7 Display Backlight and Contrast . . . . . . . . . . . . . . . . . . . 25 6.8 Taking Measurements . . . . . . . . . . . . . . . . . . . . . . . . 25 6.8.1 Connecting the Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 5

7.4.2.4 Print Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 7.4.2.5 Delete Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 7.4.3 Log Stats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 7.4.4 Data Labels . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 6

8.4.3.8 ROUTe:SCAN:MODE? [MIN|MAX|DEF] . . . . . . . . . . . . . . . . . . . . . . 95 8.4.3.9 ROUTe:SCAN:MODE |MIN|MAX|DEF . . . . . . . . . . . . . . . . . . . . 95 8.4.4 Probe Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 8.4.4.1 CALCulate:CONVert:CATalog?. . . . . . . . . . . . . . . . . . . . . . . . . 95 8.4.4.2 CALCulate:CONVert:COPY |ALL .

Summary of the content on the page No. 7

8.4.8 System Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 8.4.8.1 *IDN? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 8.4.8.2 *OPT? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 8.4.8.3 *RST. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 8

8.4.12.16 STATus:OPERation:ENABle |MIN|MAX|DEF . . . . . . . . . . . . . . . . 124 8.4.12.17 STATus:QUEStionable? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 8.4.12.18 STATus:QUEStionable:CONDition? . . . . . . . . . . . . . . . . . . . . . . . . . 125 8.4.12.19 STATus:QUEStionable:ENABle? [MIN|MAX|DEF] . . . . . . . . . . . . . . . . . 125 8.4.12.20 STATus:QUEStionable:ENABle

Summary of the content on the page No. 9

Figures Figure 1 Using the Clamp-on Ferrites . . . . . . . . . . . . . . . . . . . . . . . 14 Figure 2 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Figure 3 Back Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Figure 4 Thermocouple Connections . . . . . . . . . . . . . . . . . . . . . . . 23 Figure 5 Probe Connection Wiring Diagram

Summary of the content on the page No. 10

Figure 41 Default Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Figure 42 System Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Figure 43 Comm Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 Figure 44 Date Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Figure 45 Password . . . . .

Summary of the content on the page No. 11

Tables Table1 International Electrical Symbols . . . . . . . . . . . . . . . . . . . . . 1 Table 2 Conversion Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Table 3 Alphabetical List of Commands . . . . . . . . . . . . . . . . . . . . . 81 Table 4 Statistical Calculation Types . . . . . . . . . . . . . . . . . . . . . . 126 Table 5 Field Types . . . . . . . . . . . . . . . .

Summary of the content on the page No. 12

1 Before You Start Symbols Used 1 Before You Start 1.1 Symbols Used Table 1 lists the symbols that may be used on the instrument or in this manual Table1 International Electrical Symbols and the meaning of each symbol. Symbol Description AC (Alternating Current) AC-DC Battery Complies with European Union Directives DC (Direct Current) Double Insulated Electric Shock Fuse PE Ground Hot Surface (Burn Hazard) Read the User’s Manual (Important Information) Off 1

Summary of the content on the page No. 13

1529 Chub-E4 Thermometer Readout User’s Guide Symbol Description On Canadian Standards Association OVERVOLTAGE (Installation) CATEGORY II, Pollution Degree 2 per IEC1010-1 re- fers to the level of Impulse Withstand Voltage protection provided. Equipment of OVERVOLTAGE CATEGORY II is energy-consuming equipment to be supplied from the fixed installation. Examples include household, office, and laboratory appliances. C-TIC Australian EMC mark The European Waste Electrical and Electronic Equipment (

Summary of the content on the page No. 14

1 Before You Start Safety Information provided with the instrument or equivalent adapter recommended by the manufacturer of this instrument. • The AC adapter has circuits with high voltage inside that could present danger of electrical shock or fire if exposed. If the AC adapter is damaged in any way or becomes hot, discontinue its use immediately, disconnect it from any AC supply, and have it replaced. Do not attempt to open, repair, or continue using a damaged or defective AC adapter. • The in

Summary of the content on the page No. 15

1529 Chub-E4 Thermometer Readout User’s Guide • Keep the probe wires clean and away from fluids. 1.3 Authorized Service Centers Please contact one of the following authorized Service Centers to coordinate service on your Hart product: Fluke Corporation, Hart Scientific Division 799 E. Utah Valley Drive American Fork, UT 84003-9775 USA Phone: +1.801.763.1600 Telefax: +1.801.763.1010 E-mail: support@hartscientific.com Fluke Nederland B.V. Customer Support Services Science Park Eindhoven 5108 5692

Summary of the content on the page No. 16

1 Before You Start Authorized Service Centers Fluke South East Asia Pte Ltd. Fluke ASEAN Regional Office Service Center 60 Alexandra Terrace #03-16 The Comtech (Lobby D) 118502 SINGAPORE Phone: +65 6799-5588 Telefax: +65 6799-5588 E-mail: antng@singa.fluke.com When contacting these Service Centers for support, please have the following information available: • Model Number • Serial Number • Voltage • Complete description of the problem 5

Summary of the content on the page No. 17

2 Introduction 2 Introduction The Hart 1529 is a low-cost, high-accuracy, digital thermometer readout de - signed to be used with 25 and 100Ω PRTs, thermistors, and thermocouples. Its unique combination of features makes it suitable for a wide variety of applica- tions from laboratory measurement to industrial processes. Features of the 1529 include: • Measures 25Ω and 100Ω PRTs, thermistors, and thermocouples • Four inputs: two PRT/thermistor and two thermocouple (standard config- uration) • Fo

Summary of the content on the page No. 18

3 Specifications and Environmental Conditions Specifications 3 Specifications and Environmental Conditions 3.1 Specifications PRT Thermistor Thermocouple Inputs 2 channels PRT/thermistor and 2 channels thermocouple or 4 channels PRT/thermistor or 4 channels thermocouple PRT/thermistor channels accept 2,3, or 4 wires Thermocouple channels accept B, E, J, K, N, R, S, T, and Au-Pt thermocouple types 1 Temperature Range –189 to 960°C –50 to 150°C –270 to 1800°C Measurement Range –10 to 100 mV 0to400

Summary of the content on the page No. 19

1529 Chub-E4 Thermometer Readout User’s Guide PRT Thermistor Thermocouple Probe Connection Patented DWF connectors accepts spade lug, bare-wire, or banana Universal receptacle accepts plug terminations miniature and standard connectors Communications RS-232 and IR ports included, IEEE-488 (GPIB) optional AC Power 100 to 240 VAC, 50-60 Hz, 0.4A DC Power 12 to 16 VDC, 0.5 A (battery charges during operation from 14.5 to 16 VDC, 1.0A) Battery NiMH, 8 hours operation typical without backlight, 3 hou

Summary of the content on the page No. 20

3 Specifications and Environmental Conditions Warranty 3.3 Warranty Fluke Corporation, Hart Scientific Division (Hart) warrants this product to be free from defects in material and workmanship under normal use and service for a period as stated in our current product catalog from the date of shipment. This warranty extends only to the original purchaser and shall not apply to any product, which, in Hart’s sole opinion, has been subject to misuse, alteration, abuse or abnormal conditions of opera


Alternative user manuals
# User manual Category Download
1 Fluke 114 User manual Thermometer 24
2 Fluke 117 User manual Thermometer 414
3 Fluke 115 User manual Thermometer 126
4 Fluke 1522 User manual Thermometer 16
5 Fluke 1521 User manual Thermometer 33
6 Fluke 116 User manual Thermometer 34
7 Fluke 1523 User manual Thermometer 12
8 Fluke 1594A User manual Thermometer 4
9 Fluke 1524 User manual Thermometer 22
10 Fluke 1595A User manual Thermometer 5
11 Fluke 2180A User manual Thermometer 6
12 Fluke 233 User manual Thermometer 48
13 Fluke 2190A User manual Thermometer 15
14 Fluke 50S User manual Thermometer 20
15 Fluke 53 & 54 Series User manual Thermometer 8
16 A&D DT-103 User manual Thermometer 40
17 A&D DT-102 User manual Thermometer 24
18 A&D UT-302 User manual Thermometer 15
19 Acu-Rite 416 User manual Thermometer 7
20 Acu-Rite #00609SBDIA1 User manual Thermometer 3