Furuno SEARCHLIGHT CH-250 user manual

User manual for the device Furuno SEARCHLIGHT CH-250

Device: Furuno SEARCHLIGHT CH-250
Category: SONAR
Manufacturer: Furuno
Size: 3.66 MB
Added : 11/20/2013
Number of pages: 79
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Furuno SEARCHLIGHT CH-250. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Furuno SEARCHLIGHT CH-250.

For your convenience

If looking through the Furuno SEARCHLIGHT CH-250 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Furuno SEARCHLIGHT CH-250 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Furuno SEARCHLIGHT CH-250 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Furuno SEARCHLIGHT CH-250 User manual - Online PDF
Advertisement
« Page 1 of 79 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Furuno SEARCHLIGHT CH-250 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Furuno SEARCHLIGHT CH-250. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Installation Manual
SEARCHLIGHT SONAR CH-250
3. ADJUSTMENTS ...............................31
SAFETY INSTRUCTIONS....................... i
3.1 General Checks..................................... 31
SYSTEM CONFIGURATION................. iii
3.2 TX Frequency Checking........................ 32
3.3 Heading Adjustment/Soundome Setting
EQUIPMENT LISTS .............................. iv
.........................................................34
1. Mounting ..................................

Summary of the content on the page No. 2

The paper used in this manual is elemental chlorine free. ・FURUNO Authorized Distributor/Dealer 9-52 Ashihara-cho, Nishinomiya, 662-8580, JAPAN Telephone : +81-(0)798-65-2111 Fax : +81-(0)798-65-4200 A : MAR. 2000 All rights reserved. Printed in Japan K4 : SEP. 10, 2007 Pub. No. IME-13160-K4 (YOSH ) CH-250 *00080895011* *00080895011* **00080895011 00080895011** * 0 0 0 8 0 8 9 5 0 1 1 *

Summary of the content on the page No. 3

SAFETY INSTRUCTIONS WARNING WARNING Installe the specified transducer tank ELECTRICAL SHOCK HAZARD Do not open the equipment. in accordance with the installation instructions. If a different tank is to be Only qualified personnel installed the shipyard is solely respon- should work inside the sible for its installation, and it should equipment. be installed so the tank doesn't strike an object. Turn off the power at the switchboard The tank or hull may be damaged if the before beginning the

Summary of the content on the page No. 4

CAUTION CAUTION Ground the equipment to WORKING WITH THE SONAROIL prevent electrical shock and mutual interference. Precautions Keep oil away from eyes. Wear protective Observe the following compass safe gloves when working with the oil. The oil distances to prevent deviation of a can cause inflammation of the eyes. magnetic compass: Do not touch the oil. Wear protective Standard Steering gloves when working with the oil. The oil can cause inflammation of the skin. Monitor unit/ 0.80 m

Summary of the content on the page No. 5

SYSTEM CONFIGURATION INTERFACE UNIT IF-8000 Note 2 MONITOR UNIT MU-100C Navigator Control Unit Display Note 1 Unit VGA Ext. Monitor Remote Note 2 Controller TRANSCEIVER UNIT CONTROL UNIT CH-252 CH-253 MOTION SENSOR 12-32 VDC HULL UNIT SPEAKER DA T A/VIDEO OUT HULL UNIT 12-32 VDC Speaker CH-254/255 Motion Sensor 12/24-32 VDC Note 1: MU-100C is the standard supply display unit. An external monitor may be connected via the interface unit (option). The drawing above shows the system configuratio

Summary of the content on the page No. 6

EQUIPMENT LISTS Standard Supply Name Type Code no. Qty Remarks Control Unit/ CH-252/ 1 Not supplied with blackbox type Monitor Unit MU-100C Control Unit CH-252 1 Not supplied with unibody type Interface Unit IF-8000 1 For blackbox type Transceiver Unit CH-253 1 CH-254 400 stroke See the following Hull Unit 1 table for Hull Unit CH-255 250 stroke Standard Supply. For unibody type, SP06-01102*, SP06-01100 000-068-488 SP06-01103* 1 Spare Parts For blackbox type, SP06-01102

Summary of the content on the page No. 7

Hull Unit (1) Code no. Type Spec. Stroke Power Frequency Shaft Cable 000-068-515 CH-254-1-60-22-35 400 mm 12 V 60 kHz 2.2 m 3.5 m 000-068-516 CH-254-1-88-22-35 88 kHz 000-068-517 CH-254-1-150-22-35 150 kHz 000-068-518 CH-254-1-180-22-35 180 kHz 000-068-519 CH-254-1-240-22-35 240 kHz 000-068-559 CH-254-1-60-22-52 60 kHz 2.2 m 5.2 m 000-068-560 CH-254-1-88-22-52 88 kHz 000-068-561 CH-254-1-150-22-52 150 kHz 000-068-562 CH-254S-1-180-22-52 180 kHz 000-068-563 CH-254S-1-240-22-52 240 kHz

Summary of the content on the page No. 8

Hull Unit Standard Supply Name Type Code no. Qty Remarks Raise/lower CH-2541 - 1 set Drive Unit CH-2551 - Soundome CH-2542 - 1 set See the following Soudome table. Flange CH-2543 006-557-810 1 set Flange, grease cotton Assembly Kit for CH-2544 006-557-820 1 set Shaft, retraction tank, seal, field adhesives, tank guide, material box Shaft SHJ-0006-1 661-000-061 1 2.2 m, for 3.5/5.2 m cable 06-007-1572-0 600-715-720 3.8 m, for 5.2m cable Sonar Oil 4 lit. 000-824-033 1 vi

Summary of the content on the page No. 9

Shaft parts Name Type Code no. Qty Remarks Pipe cap SHN-0011-0 661-400-110 1 Jubilee Clip 1X28-41 000-801-857 1 Hex. bolt M10X35 SUS304 000-862-175 2 U-nut M10 SUS304 000-863-930 2 Flat washer M10 SUS304 000-864-131 4 Tank parts Name Type Code no. Qty Remarks Hex. bolt M20X80 SUS304 000-801-893 8 Hex. nut M20 SUS304 000-863-116 16 Flat washer M20 SUS304 000-864-136 16 Spring washer M20 SUS304 000-864-270 8 Adhesives Name Type Code no. Qty Remarks Kinolastar 855 000-801-3

Summary of the content on the page No. 10

Cables for Installation materials Type Code no. Specification (Cable between unit) Monitor unit (or IF) Transceiver unit and Hull unit Crimp-on lug and Transceiver unit CP06-01200 000-068-496 06S4078*5m* 06S4080*15m* CP06-01251* CP06-01201 000-068-497 06S4080*30m* CP06-01251* CP06-01202 000-068-498 06S4080*50m* CP06-01251* CP06-01203 000-068-499 06S4078*10m* 06S4080*15m* CP06-01251* CP06-01204 000-068-500 06S4080*30m* CP06-01251* CP06-01205 000-068-502 06S4080*50m* CP06-01251* Control

Summary of the content on the page No. 11

1. Mounting NOTICE Do not apply paint, anti-corrosive sealant or contact spray to coating or plastic parts of the equipment. Those items contain organic solvents that can damage coating and plastic parts, especially plastic connectors. 1.1 Monitor Unit/Control Unit This searchlight sonar has two types of shipment, standard type which is shipped with monitor unit and blackbox type which is shipped without monitor unit, but has interface unit. For blackbox type, see page 4. The control

Summary of the content on the page No. 12

2. For unibody mounting; a) Fasten the bracket at the rear of monitor and control units with four binding screws (M4x10). Bracket (rear view) 1 2 1 2 3 4 3 4 Bracket, rear view 3. For separate/blackbox mounting; a) Dismount the coupling plate to separate monitor unit and control unit. b) Attach the bracket at rear of the monitor unit with four binding screws (M4x10). Bracket (rear view) 1 2 1 2 4 3 4 3 Bracket, rear view 4. Coat threads of upset screws (M6x16, 2 pcs.) used to fasten

Summary of the content on the page No. 13

Flush mounting Flush mounting for unibody (Type: OP06-16, Code no.: 006-556-300) Name Type Code No. QtyRemarks Fixing metal 06-021-1311-2 100-279-612-10 1 Self-tapping screw 5x20 000-162-609-10 6 Hex. bolt M4x12 000-162-939-10 4 1. Make holes at the place to mount (W287 x H297). 2. Fasten monitor and control units with the fixing metal (supplied as option) and four hex. bolts (supplied as option). 3. Fasten the fixing metal assembled at step 2 to holes made at step 1 with six tap

Summary of the content on the page No. 14

Hex. Bolts Fixing Metal Flush mounting for control unit Type: OP02-83-1.5, Code no.: 001-413-600 (1.5 m cable) OP03-83-5, Code no.: 001-413-610 (5m cable) Name Type Code No. Qty Remarks Fixing metal 06-021-2101-2 100-279-732-10 1 Self-tapping screw 5x20 000-162-609-10 4 Hex. bolt M4x12 000-162-939-10 2 MJ-A10SPF0002-0 Cable assembly 000-142-878 1 1.5 m Select one. 15 MJ-A10SPF0002-0 000-131-411 1 5 m 50 1. Make holes at the place to mount (W287 x H87). 2. Fasten the fixing met

Summary of the content on the page No. 15

1.1.4 Control unit On blackbox type, fix the control unit to the mounting plate (supplied as accessories). See the parts list of FP06-01120 and outline drawings at the back of this manual. 1. Fix the mounting plate to the place selected with two tapping screws (5x20, supplied). 2. Fix the bracket to the control unit with two hex. screws (M4x12, supplied). 3. Insert the screw driver from the top of the mounting plate holes and then tighten two hex. screws (M4x12) loosely. 4. Attach the c

Summary of the content on the page No. 16

1.2 Transceiver Unit 1.2.1 General mounting considerations • The mounting location should be well ventilated and dry. • The unit can be mounted on bulkhead or the deck. • Secure the maintenance space shown in drawing below for ease of maintenance and service. • The maximum cable length between the transceiver unit and the raise/lower drive unit cable is 50 m. • The maximum cable length between the transceiver unit and the monitor (interface) unit is 10 m. 1.2.3 Mounting method Fasten

Summary of the content on the page No. 17

1/2 1/3 Within 1 meter Installation location for hull unit • Select a place where interference from the transducers of other sounding equipment is minimal. The hull unit should be at least 2.5 meters away from the transducers of other sounding equipment. • An obstacle in the fore direction not only causes a shadow zone but also aerated water, resulting in poor sonar performance. Be sure to locate the transducer well away from any obstacle in the fore direction. Mounting method A typica

Summary of the content on the page No. 18

For small FRP ship For small FRP ship retraction tank should be 2 degrees against ship’s draft. Therefore, this creates high water pressure in the tank because of the resistance at the rear of the tank well. To solve this problem, attach a fin to the hull at the location shown in figure below. Retraction dome Bottom of ship Fin This fin makes a smooth stream in the retraction dome. Attach the fin (height:1-1.5 cm, FRP). Mounting of transducer tank Install the transducer tank referrin

Summary of the content on the page No. 19

1.3.4 Assembling and mounting of hull unit The hull unit is shipped as the parts shown in the hull unit kit on Equipment Lists (page iv and after). Assemble the hull unit as shown in the procedure below. Necessary tools Name Specification Remarks Recommended: double offset Wrench For M10 (Hex. size 17 mm) wrench Wrench For M20 (Hex. size 20 mm) Pipe Wrench 55 mm For fixing gland Ball Wrench Hex size 4 mm For fixing the dome 1. Calculate necessary length of main shaft from the lengt

Summary of the content on the page No. 20

Raise/lower section Flat Nut washer Hex. bolt Shaft sleeve (M10X30) Spring washer Flat washer Trunnion pin Shaft sleeve and raise/lower drive unit assembly 3. Pass the transducer cable through the main shaft. 10 WARNING WARNING


Alternative user manuals
# User manual Category Download
1 Furuno CH-250 User manual SONAR 286
2 Furuno CH-28 User manual SONAR 81
3 Furuno CH-32 User manual SONAR 3
4 Furuno CH-300 User manual SONAR 85
5 Furuno CH-270 User manual SONAR 46
6 Furuno CH-34/36 User manual SONAR 29
7 Furuno COLOR SCANNING CSH-23F/24F User manual SONAR 4
8 Furuno CH-37 User manual SONAR 54
9 Furuno AV550SC User manual SONAR 3
10 Furuno CH-36 User manual SONAR 23
11 Furuno CI-60G User manual SONAR 9
12 Furuno COLOR SCANNING CSH-55 User manual SONAR 2
13 Furuno CSH-23 User manual SONAR 1
14 Furuno CSH-23/24 User manual SONAR 4
15 Furuno CSH-24F User manual SONAR 5
16 A&D AD-4406 User manual SONAR 23
17 Adam Equipment 9520 User manual SONAR 0
18 ClearOne comm unicationsGT1524 User manual SONAR 1
19 Eagle Electronics CUDA 240I S User manual SONAR 12
20 Eagle Electronics CUDA 242 User manual SONAR 270