Gentek 3940220 user manual

User manual for the device Gentek 3940220

Device: Gentek 3940220
Category: Scale
Manufacturer: Gentek
Size: 1.5 MB
Added : 5/9/2013
Number of pages: 101
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Gentek 3940220. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Gentek 3940220.

For your convenience

If looking through the Gentek 3940220 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Gentek 3940220 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Gentek 3940220 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Gentek 3940220 User manual - Online PDF
Advertisement
« Page 1 of 101 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Gentek 3940220 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Gentek 3940220. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

User’s Manual

XPert Filtered Balance Systems &

XPert Filtered Balance Stations
Models
3940200, 3940201, 3940202, 3940220, 3940221,
3940222, 3940300, 3940301, 3940302, 3940320,
3940321, 3940322, 3940400, 3940401, 3940402,
3940420, 3940421, 3940422
3950200, 3950201, 3950202, 3950220, 3950221,
3950222, 3950300, 3950301, 3950302, 3950320,
3950321, 3950322, 3950400, 3950401, 3950402,
3950420, 3950421, 3950422
Labconco’s Mascot,
Labby the LABster

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Labconco XPert Filtered Balance System/Station Manual Warranty Labconco provides a warranty on all parts and factory workmanship. The warranty includes areas of defective material and workmanship, provided such defect results from normal and proper use of the equipment. The warranty for all Labconco products will expire one year from date of installation or two years from date of shipment from Labconco, whichever is sooner, except the following: • Purifier® Delta® Ser

Summary of the content on the page No. 4

TABLE OF CONTENTS TABLE OF CONTENTS CHAPTER 1: INTRODUCTION 1 About This Manual 3 Typographical Conventions 4 CHAPTER 2: PREREQUISITES 5 Support, Vibration & Movement Requirements 6 Temperature Variation Requirements 6 Humidity and Static Electricity Requirements 7 Background on Electrostatics or Static Electricity 7 Location and Air Current Requirements 8 Exhaust and Blower Requirements 8 E

Summary of the content on the page No. 5

Filters with Volatile Chemicals 40 Chemical Carcinogen Use with Odor Control Carbon Filters 41 Prohibited Acid Use 41 CHAPTER 6 MAINTAINING YOUR FILTERED ENCLOSURE 43 Routine Maintenance Schedule 44 Decontamination 45 Determination of when to Replace HEPA Filters 45 How to Install a New HEPA Filter with Bag-In/Bag-Out Procedure for XPert Filtered Balance Systems and Stations 46 HEPA Filter Leak Test 47 Settin

Summary of the content on the page No. 6

CHAPTER 1 HAPTER C 1 INTRODUCTION INTRODUCTION Congratulations on your purchase of a Labconco XPert™ Filtered Balance System or XPert™ Filtered Balance Station. Your enclosure provides personnel protection through superior containment while conserving energy at OSHA approved velocities as low as 60 feet per minute. It is the result of Labconco’s more than 50 years experience in manufacturing fume hoods and more than 30 years experience in manufacturing filter

Summary of the content on the page No. 7

Chapter 1: Introduction filtered enclosures include a true bag-in/bag-out HEPA filter to properly protect personnel during filter changing operations. See chart below and contact Labconco for additional ordering information. Bag-in/Bag-out UV No. Application Product Filters HEPA Light 1. Weighing XPert Filtered HEPA Required, Hazardous & Balance included with Nuisance System, XPert XPert No Powders & Filtered Particulates Balance Station 2. Weighing XPert Filtered HEPA Re

Summary of the content on the page No. 8

Chapter 1: Introduction About This Manual This manual is designed to help you learn how to install, use, and maintain your filtered enclosure. Instructions for installing optional equipment or accessory carbon filters on your filtered enclosure are also included. Chapter 1: Introduction provides a brief overview of the filtered enclosure, explains the organization of the manual, and defines the typographical conventions used in the manual. Chapter 2: Prerequisites explains wh

Summary of the content on the page No. 9

Chapter 1: Introduction Appendix C: Specifications contains the electrical requirements for filtered enclosures. Wiring diagrams are also included. Appendix D: Quick Chart provides an airflow table and test data for the filtered enclosures. Appendix E: References lists the various resources available that address laboratory ventilation and biosafety. Typographical Conventions Recognizing the following typographical conventions will help you understand and use this manual:

Summary of the content on the page No. 10

CHAPTER 2 HAPTER C 2 PREREQUISITES PREREQUISITES Before you install the filtered enclosure, you need to prepare your site for installation. You must be certain that the area is level and of solid construction. In addition, a dedicated source of electrical power should be located near the installation site to power the filtered enclosure, balance and other apparatus. Additionally, the enclosure should be strategically placed in the lab to provide efficient wo

Summary of the content on the page No. 11

Chapter 2: Prerequisites Support, Vibration and Movement Requirements At a minimum, the supporting structure usually consists of a base cabinet and chemical-resistant work surface. The ability for analytical balances to accommodate vibration varies with type and brand. More advanced balances have improved tolerance, however in the preparation of a balance enclosure site, please consider the following: • Avoid tubular stands or mobile benches that have the potential of moving w

Summary of the content on the page No. 12

Chapter 2: Prerequisites Humidity and Static Electricity Requirements Electrostatics can be troublesome in a balance enclosure. It is important to understand and, to the extent possible, control static charges. An electrostatic charged vessel, sample or enclosure can apply forces and lead to errors in weighing. The repulsion or attraction can be detected with micro, semi micro and analytical balances. Static charges can also lead to particulates being attracted to surfaces withi

Summary of the content on the page No. 13

Chapter 2: Prerequisites The ability of a material to become polarized is a property known as permittivity. On highly insulative materials like acrylic, ions or charged molecules are strongly bound to the surface by polarization forces. The higher the force, the higher is the permittivity value of the material. It is suggested by balance manufacturers that the use of high permittivity materials, such as plastic be avoided. Since static electricity is a surface phenomenon, materi

Summary of the content on the page No. 14

Chapter 2: Prerequisites The HEPA-filtered exhaust air can be recirculated into the laboratory or exhausted outside with the addition of the exhaust connection kit and remote blower listed in Chapter 7. The XPert Filtered Balance Station does not include the motorized impeller and must be exhausted to the outside by a remote blower. XPert The XPert Filtered Balance Station remote blower may be Station switched from the blower switch on the enclosure. See electrical Requirements

Summary of the content on the page No. 15

Chapter 2: Prerequisites Proper blower selection can be determined from these exhaust requirements and the total system static pressure loss. For outside exhaust, the enclosure must be connected to either a dedicated blower or a house exhaust system. Labconco offers accessory remote blowers listed in Chapter 7. Contact Labconco for blower sizing assistance. If the enclosure is connected directly to a house exhaust system, an adjustable damper (or valve) must be installed to con

Summary of the content on the page No. 16

CHAPTER 3 CHAPTER 3 GETTING STARTED ETTING TARTED G S Now that the site for your filtered enclosure is properly prepared, you are ready to unpack, inspect, install, and validate your system. Read this chapter to learn how to: • Unpack and move the enclosure. • Set up the enclosure with the proper supporting structure and work surface. • Connect to an exhaust system if applicable. • Installation of HEPA and accessory Odor Control carbon filters. • Connect the el

Summary of the content on the page No. 17

Chapter 3: Getting Started Unpacking the Enclosure Carefully remove the shrink-wrap or carton on the enclosure and The United States Interstate Commerce inspect it for damage that may have occurred in transit. If Commission rules damaged, notify the delivery carrier immediately and retain the require that claims be entire shipment intact for inspection by the carrier. filed with the delivery carrier within fifteen (15) DO NOT RETURN GOODS WITHOUT THE days of delivery. PRIOR

Summary of the content on the page No. 18

Chapter 3: Getting Started 0.36" of the front of the work surface. Mounting holes are provided in the Labconco accessory work surfaces to secure the enclosure. Work Surface Specifications The work surface should be smooth, rigid, and durable, such as a chemical-resistant epoxy resin. The surface should be non-porous and resistant to the powders, solvents and chemicals used in conjunction with the XPert Filtered Enclosure. The work surface should also contain a dished recessed a

Summary of the content on the page No. 19

Chapter 3: Getting Started Figure 3-1 Filtered Enclosure Installation 14

Summary of the content on the page No. 20

Chapter 3: Getting Started Connecting to the XPert Exhaust System (Optional Station on XPert Filtered Balance System) WARNING: The weight of the exhaust ductwork system must be supported ! independently of the enclosure superstructure or damage may occur. The exhaust system should be installed by a qualified HVAC contractor. The exhaust connection on the XPert Filtered Balance Station has been designed to accept 6" diameter ductwork as shown in Figure 3-2. T


Alternative user manuals
# User manual Category Download
1 Gentek 3940222 User manual Scale 0
2 Gentek 3940320 User manual Scale 38
3 Gentek 3940300 User manual Scale 0
4 Gentek 3940201 User manual Scale 0
5 Gentek 3940302 User manual Scale 2
6 Gentek 3940202 User manual Scale 0
7 Gentek 3940402 User manual Scale 0
8 Gentek 3940301 User manual Scale 0
9 Gentek 3940400 User manual Scale 0
10 Gentek 3940322 User manual Scale 0
11 Gentek 3940321 User manual Scale 0
12 Gentek 3940401 User manual Scale 0
13 Gentek 3940221 User manual Scale 0
14 Gentek 3940421 User manual Scale 0
15 Gentek 3950201 User manual Scale 0
16 A&D Ej Series Compact Balance EJ-1500 User manual Scale 17
17 A&D A & D Analytical Balance GH-120/GH-200/GH-300/GH-202/GH-252 User manual Scale 13
18 A&D Ej Series Compact Balance EJ-440 User manual Scale 0
19 A&D FG-150KAL User manual Scale 1
20 A&D Ej Series Compact Balance EJ-2000 User manual Scale 2