Excell Precision Weighing user manual

User manual for the device Excell Precision Weighing

Device: Excell Precision Weighing
Category: Scale
Manufacturer: Excell Precision
Size: 0.27 MB
Added : 2/28/2014
Number of pages: 21
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Excell Precision Weighing. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Excell Precision Weighing.

For your convenience

If looking through the Excell Precision Weighing user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Excell Precision Weighing on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Excell Precision Weighing to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Excell Precision Weighing User manual - Online PDF
Advertisement
« Page 1 of 21 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Excell Precision Weighing but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Excell Precision Weighing. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

EXCELL PRECISION CO., LTD




























© Excell Precision Limited 2005. All rights reserved Worldwide.
The information contained herein is the property of Excell Precision Limited
and is supplied without liability for errors or omissions. No part may be
reproduced or used except as authorised by contract or other written
permission. The copyright and the foregoing restriction on reproduction
and use extend to all media in which the information

Summary of the content on the page No. 2

Summary of the content on the page No. 3

EXCELL PRECISION CO., LTD. TABLE OF CONTENTS INSTRUCTION FOR USE............................................................................................................2 PREPARING TO USE THE SCALE.............................................................................................2 CHAPTER 1 FEATURES AND SPACIFICATIONS......................................................................3 1. Features ..........................................................................

Summary of the content on the page No. 4

EXCELL PRECISION CO., LTD. INSTRUCTION FOR USE Thank you for purchasing the 9903 Dolphin II weighing scale of Excell. To enable you to use this scale correctly, we suggest that you read the following instructions carefully. 1. Don’t bump the scale against other items nor load it with heavy weight exceeding its full capacity. 2. Keep it away from high temperature. 3. If the scale is not going to be used for a certain period of time, clean it and store it in a polythene bag. A desicc

Summary of the content on the page No. 5

EXCELL PRECISION CO., LTD. CHAPTER 1 FEATURES AND SPACIFICATIONS 1. Features 2 IP65 Wash down design 2 Auto calibration 2 Large LCD display with LED backlight included 2 Kilogram (kg) and pound (lb) weighing modes 2 Full range tare; Auto zero tracking 2 Adjustable gravity value 2 Simple counting; Gross/Net indication; Hold function; Check mode Lo/Hi/OK 2 Low power indication and auto power off 2 Easily adjusted leveling feet for stability of the scale 2. Options 2 Second

Summary of the content on the page No. 6

EXCELL PRECISION CO., LTD. 4. Power Supply Power Source: AC 110V/230V (±10%) adaptor; 4 x UM-1 1.5V dry batteries; or 6V / 1.2Ah rechargeable battery Power Consumption: With backlight: about DC 14 mA; battery life about 85 hours Without backlight: about DC 24 mA; battery life about 50 hours Low Battery Indication: When the symbol flashes, the battery needs to be recharged or the dry battery needs to be replaced. 4 The scale will power off automatically after 1 to 2 hours i

Summary of the content on the page No. 7

EXCELL PRECISION CO., LTD. CHAPTER 2 DISPLAY 1 2 3 4 5 6 7 HI : When this indicator is on, the weight value is larger than the preset high limit. OK : When this indicator is on, the weight value is between the low and high limits. LO : When this indicator is on, the weight value is less than the preset low limit. kg : Indicating that the current weighing unit is “kg”. lb : Indicating that the current weighing unit is “lb”. Pcs : Indicating that the scale is in the simple cou

Summary of the content on the page No. 8

EXCELL PRECISION CO., LTD. CHAPTER 3 KEYBOARD FUNCTION OFF 1. : Pressed to switch the scale off ON ZERO 2. : When the scale is off, pressed to switch it on. When the scale is on, if the weight is within the zero range, this key is pressed to re-zero the display or cancel the tare mode. 4 Zero range: OIML & NTEP: ±2% of full scale; Sri Lanka: ±4% of full scale TARE 3. : Pressed to deduct the container weight. UNITS 4. : Pressed to choose the unit weight

Summary of the content on the page No. 9

EXCELL PRECISION CO., LTD. CHAPTER 4 BASIC FUNCTION OPERATION 1. Switch On ON ZERO When the scale is off, press the key to switch on the scale 2. Re-Zero When there is no load on the platter, if the displayed weight is not zero and is within the ON ZERO zero range, press the key to re-zero the scale, and the indicator “à0ß” is on. 4 Zero range: OIML & NTEP: ±2% of full scale; Sri Lanka: ±4% of full scale 3. Unit Selection UNITS Press the key to cho

Summary of the content on the page No. 10

EXCELL PRECISION CO., LTD. 4. Tare Function (1) Put the container on the platter. When the weight displayed is stable, press the TARE key. The weight of the container is thus deducted, and the “Net” indicator is on. (2) Put the object to be weighed into the container, and the display shows the net weight of the object. (3) Remove the container and the object together from the platter. The display will show the negative value of the container weight. TARE (4) Press

Summary of the content on the page No. 11

EXCELL PRECISION CO., LTD. 6. Simple Counting 6-1 Counting mode access UNITS Press the key to select the “Pcs” unit, and the scale enters the simple counting mode. 6-2 Sampling This important procedure is to let the scale calculate the unit weight: NET GROSS (1) Press the key to select a sample size 10, 20, 50, 100 or 200. (2) Put enough samples onto the platter according to the selected number, and then UNITS press the key. The display shows “- - - - - -” f

Summary of the content on the page No. 12

EXCELL PRECISION CO., LTD. CHAPTER 5 ADVANCED FUNCTIONS SETTING 4 To access the advanced functions setting, press the NET/GROSS key and the ON/ZERO key at the same time when the scale is in the weighing mode. The display shows . Press the UNITS key Press the ON/ZERO key Press the UNITS key Press the ON/ZERO key Press the UNITS key Press the ON/ZERO key ⇒ Func

Summary of the content on the page No. 13

EXCELL PRECISION CO., LTD. 1. Function Setting 4 Six functions ~ can be set here. Press the TARE key Input “00 ~ 06” If input “00”, press the TARE key to return to the upper level category. ON/ZERO ⇒ Upward digit selecting (0-9) UNITS ⇒ Downward digit selecting (9-0) TARE ⇒ Move the cursor rightward NET/GROSS ⇒ Move the cursor leftwa

Summary of the content on the page No. 14

EXCELL PRECISION CO., LTD. 1-1 Auto Backlight Setting Press the TARE key The display shows the current backlight setting. Press the ON/ZERO or UNITS key to select “on” or “off”. Auto backlight setting on ⇒ Turn on the auto backlight off ⇒ Turn off the auto backlight Press the TARE key Auto backlight mode 1. When there is weight on the platte

Summary of the content on the page No. 15

EXCELL PRECISION CO., LTD. 1-2 Auto-off Timer Setting Press the TARE key The display shows the current setting Auto-off timer setting 0 ⇒ Auto-off not functional Press the ON/ZERO 1 ⇒ If the scale is not operated for 1 minute, or UNITS key to input it will automatically switch off. a parameter 2 ⇒ If the scale is not operated for 2 minutes, it will automatically switch off. 9 ⇒ If th

Summary of the content on the page No. 16

EXCELL PRECISION CO., LTD. 1-3 Check-Weighing Setting 4 If both the preset high limit and the low limit values are set as 0, the check-weighing function is invalid. Press the TARE key The display shows the current setting of high limit value kg . Input the desired high limit value kg . Press the TARE key The display shows the current setting of low limit value kg . Input the desired low

Summary of the content on the page No. 17

EXCELL PRECISION CO., LTD. 1-4 Restore to the Factory Setting Press the TARE key Return to upper level category (abort restoring) Press the ON/ZERO or UNITS key to select “return” or “format”. Restore to the factory setting Press the TARE key 4 The restored factory settings include the following: (1) External weight calibration (2) Check-weighing setti

Summary of the content on the page No. 18

EXCELL PRECISION CO., LTD. 1-5 Environment Parameter Setting 4 The parameters in remain the same after the ones has been modified in Return-to-zero-point setting The display shows the current setting Return-to-zero-point setting Press the TARE key Default setting = 0 0 ⇒ No skip 5 ⇒ skip 5d 1 ⇒ skip 1d 6 ⇒ skip 6d 2 ⇒ skip 2d 7 ⇒ skip 7d 3 ⇒ skip 3d 8 ⇒ skip 8d Use the ON/ZERO or UN

Summary of the content on the page No. 19

EXCELL PRECISION CO., LTD. 1-6 Hold Function Setting Press the TARE key The display shows the current hold function mode Use the ON/ZERO or UNITS Hold function setting key to input a parameter Default setting = 0 0 ⇒ No hold function 1 ⇒ “peak” hold function mode 2 ⇒ “stable” hold function mode 1 3 ⇒ “stable” hold function mode 2 Press the TARE key Input “00”

Summary of the content on the page No. 20

EXCELL PRECISION CO., LTD. 2. External Weight Calibration The display shows the calibration Press the TARE key weight (equals to the full capacity) and the weight unit. The last digit flashes. kg 4 The calibration weight can be . modified if necessary. Put the platter on and make sure there is no weight on the platter. Then press the TARE key. The scale is calculating the internal kg value of the zero point.


Alternative user manuals
# User manual Category Download
1 Excell Precision Counting User manual Scale 1
2 Excell Precision DIGITAL HIGH PRECISION WEIGHING S User manual Scale 6
3 Excell Precision High Precesion Counting User manual Scale 0
4 Excell Precision FM User manual Scale 5
5 Excell Precision www.excell.com.tw/excell_en/uploads/product/200712... User manual Scale 30
6 Excell Precision WEIGHING S User manual Scale 8
7 A&D Ej Series Compact Balance EJ-1500 User manual Scale 17
8 A&D A & D Analytical Balance GH-120/GH-200/GH-300/GH-202/GH-252 User manual Scale 13
9 A&D Ej Series Compact Balance EJ-440 User manual Scale 0
10 A&D FG-150KAL User manual Scale 1
11 A&D Ej Series Compact Balance EJ-2000 User manual Scale 2
12 A&D Ej Series Compact Balance EJ-4100 User manual Scale 5
13 A&D Ej Series Compact Balance EJ-120 User manual Scale 2
14 A&D Ej Series Compact Balance EJ-6100 User manual Scale 5
15 A&D FG-150KBM User manual Scale 0