Excell Precision DIGITAL HIGH PRECISION WEIGHING S user manual

User manual for the device Excell Precision DIGITAL HIGH PRECISION WEIGHING S

Device: Excell Precision DIGITAL HIGH PRECISION WEIGHING S
Category: Scale
Manufacturer: Excell Precision
Size: 0.3 MB
Added : 2/28/2014
Number of pages: 26
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Excell Precision DIGITAL HIGH PRECISION WEIGHING S. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Excell Precision DIGITAL HIGH PRECISION WEIGHING S.

For your convenience

If looking through the Excell Precision DIGITAL HIGH PRECISION WEIGHING S user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Excell Precision DIGITAL HIGH PRECISION WEIGHING S on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Excell Precision DIGITAL HIGH PRECISION WEIGHING S to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Excell Precision DIGITAL HIGH PRECISION WEIGHING S User manual - Online PDF
Advertisement
« Page 1 of 26 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Excell Precision DIGITAL HIGH PRECISION WEIGHING S but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Excell Precision DIGITAL HIGH PRECISION WEIGHING S. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

EXCELL PRECISION CO., LTD.







DIGITAL HIGH PRECISION
WEIGHING SCALES


USER INSTRUCTIONS














© Excell Precision Limited 2004. All rights reserved Worldwide.
The information contained herein is the property of Excell Precision Limited and is
supplied without liability for errors or omissions. No part may be reproduced or used
except as authorised by contract or other written permission. The copyright and the
foregoing restriction on reproduction

Summary of the content on the page No. 2

Summary of the content on the page No. 3

EXCELL PRECISION CO., LTD. TABLE OF CONTENTS BEFORE USING THE SCALE.....................................................................................................3 PREPARING TO USE THE SCALE.............................................................................................3 INTRODUCTION..........................................................................................................................4 1. FEATURES...............................................

Summary of the content on the page No. 4

EXCELL PRECISION CO., LTD. 2. RELAY OUTPUT.................................................................................................................23 (1) Relay Output..................................................................................................................23 (2) Relay Pin Description ....................................................................................................23 (3) Connection Illustration ........................................

Summary of the content on the page No. 5

EXCELL PRECISION CO., LTD. BEFORE USING THE SCALE To enable you to use this scale correctly, we suggest that you read this manual carefully. 1. Do not use scale in areas with excessive water and don’t spray the scale or indicator with water when cleaning. Remove all water from the scale and indicator with a clean dry cloth. 2. The load placed on the platform must not exceed the maximum weighing capacity of the scale. 3. Keep the scale away from high temperatures and da

Summary of the content on the page No. 6

EXCELL PRECISION CO., LTD. INTRODUCTION 1. FEATURES 1. Dual-weighing units: Kilogram (kg) and pound (lb). 2. Multi-function operation: Full range tare; Pre-tare; Hold function; Net / Gross weight display; Simple counting; Preset weight value and quantity value; Adjustable noise filter setting from 01 ~ 15 (≥15,000 division configuration only); Check-weighing configuration. 3. User-friendly design: ♦ Auto calibration ♦ AC / DC power supply ♦ Large LCD display with built

Summary of the content on the page No. 7

EXCELL PRECISION CO., LTD. 2. SPECIFICATIONS The available capacities for selection are different and depend on various models: Capacity Division 3 kg (6 lb) 0.2 g (0.0005 lb) 6 kg (12 lb) 0.2 g (0.0005 lb) 7.5 kg (15 lb) 0.5 g (0.001 lb) 15 kg (30 lb) 1 g (0.002 lb) 30 kg (60 lb) 2 g (0.005 lb) 75 kg (60 lb) 5 g (0.01 lb) 150 kg (150 lb) 10 g (0.02 lb) 300 kg (600 lb) 20 g (0.05 lb) 600 kg (1200 lb) 50 g (0.1 lb) Operating Temperature: 0°C ~ 40°C (32°F ~ 104°F) OI

Summary of the content on the page No. 8

EXCELL PRECISION CO., LTD. LCD DISPLAY SYMBOLS 1 2 3 4 5 HIGH : Preset High Limit Weight Value OK : The range between Low & High Limit Weight Value LOW : Preset Low Limit Weight Value kg : “kg” unit lb : “lb” unit Pcs : “COUNTING” mode indicating the number of pieces à0ß : “ZERO” indication and platform stable confirmation Net : “Net Weight ”indication : “Low Battery” indication 61 : (STABLE) “Stab

Summary of the content on the page No. 9

EXCELL PRECISION CO., LTD. KEYBOARD FUNCTION UNITS 1. : Units Key to choose the desired unit weight (kg or lb). 2. : Preset High & Low Limit value. ^ / 3. : Ù ⇒ Data Entry Key, ⇒ Backlight Key. / 4. : ↵ ⇒ Print Key to print the total data ; ↵ ⇒ Confirmation Key. 5. : Sample Key to set the sample quantity. Pcs 6. : Accumulation Key to add the displayed value into memory. M+ 7. : Re-call accumulated or preset high & low limit

Summary of the content on the page No. 10

EXCELL PRECISION CO., LTD. OPERATION 1. DISPLAY BACKLIGHT ^ / Press the key to choose the desired display backlight mode: . ⇒ “Auto Backlight” mode. When the weight is over 10 divisions or any key is pressed, the display backlight will be switched on. When the weight returns to zero or the weight on platform is less than 10 divisions, the display backlight will switch off after 5 seconds. . ⇒ Display backlight is on all the time. . ⇒ Di

Summary of the content on the page No. 11

EXCELL PRECISION CO., LTD. I. Weight Totalising DISPLAY ACTION kg . 6 Place the object onto the STABLE scale. The display shows kg the weight value . 6 STABLE Press the M+ key The display shows the total number of additions The total weight totalised kg rd shows and the 3 “6” . 6 flashes on the display 6 M+ STABLE v The totalising function can be used up to

Summary of the content on the page No. 12

EXCELL PRECISION CO., LTD. (3). Deduction of the Container Weight I. The weight of the container is unknown ( Tare ) DISPLAY ACTION kg Place the container onto the . scale 6 STABLE T Press the key when the kg weight is stable. Net . The weight value becomes 6 zero and the (Net) symbol is STABLE displayed kg Place the object into the Net . container and the display 6 sh

Summary of the content on the page No. 13

EXCELL PRECISION CO., LTD. IV. The weight of the container is known (Pre-set tare) DESCRIPTION DISPLAY ACTION kg Press the PT key . The display shows the weight value 6 Use the ∧ key to enter the STABLE of the container with the negative weight value of the container sign and the (Net) symbol. The followed by pressing the ↵ kg second “6” above the (PT) icon Net key indicates the tare is active . 6 6 STABLE

Summary of the content on the page No. 14

EXCELL PRECISION CO., LTD. (4). Check Weighing Press the key to enter the check weighing function. Press the key to UNITS return back to the weighing mode. I. Pre-set the “Low limit value”, “High limit value”, and “the buzzer” operation ^ / Press the key to enter the value required and step to the next digit by pressing the key. / ↵ DESCRIPTION DISPLAY ACTION Press the key to select kg the check weig

Summary of the content on the page No. 15

EXCELL PRECISION CO., LTD. II. Pre-set the Low limit value only After completing the Low limit value setting, the display shows . . Press the kg key to complete the setting, and the display shows . 6 STABLE v When users only pre-set the Low limit value, the buzzer setting is fixed at: III. High/OK/Low indications

Summary of the content on the page No. 16

EXCELL PRECISION CO., LTD. 4. COUNTING FUNCTION . . . . . . Press the key to enter the counting function. Press the key to return back UNITS . . . . to the weighing mode. (1). Sampling DISPLAY ACTION . . . . . . Press the key to enter the . . . . counting function Pcs 6 STABLE Pcs Press to choose the Pcs number of desired items in the 6 sample (10, 20

Summary of the content on the page No. 17

EXCELL PRECISION CO., LTD. CONFIGURATION SETTINGS Switch on the scale. While the scale is counting backward to zero, press and hold the →0← key until the display shows the software program version number: “ ”. →0← Release the key, the scale enters the configuration setting mode. is displayed. Press the TARE key Press the Press the Press the Ù Ù Ù k k ke e ey y y Press the TARE key Press the Ù key Press the

Summary of the content on the page No. 18

EXCELL PRECISION CO., LTD. 1. CHECK-WEIGHING CONFIGURATION ♦ F8 (Hold) affects access to F4. If F8 is set, access to F4 is denied. T Press the ^ / or key to select the F4 function⇒ the display shows DESCRIPTION DISPLAY ACTION Press the ↵ key to enter the check weighing configuration Press the ↵ key kg for 5 times to clear . 6 the configuration STABLE Press the ∧ key to enter the settings low limi

Summary of the content on the page No. 19

EXCELL PRECISION CO., LTD. 2. RS-232 SETTING ♦ J1 and J3 on the RS-232 interface are connected together (short), when the RS-232 interface is connected to a computer. ♦ J2 and J4 on the RS-232 interface arte connected together (short), when the RS-232 interface is connected to a printer. ^ / T Press the or keys to select the F5 function ⇒ the display shows DESCRIPTION DISPLAY ACTION Press the ↵ key 0 Þ No transmiss

Summary of the content on the page No. 20

EXCELL PRECISION CO., LTD. 3. EXIT CONFIGURATION SETTINGS T ^ / Press the or key to select the F6 function⇒ the display shows DISPLAY ACTION Press the ↵ key Scale reverts back to the weighing mode V1.0 18 SM2020010426


Alternative user manuals
# User manual Category Download
1 Excell Precision Counting User manual Scale 1
2 Excell Precision High Precesion Counting User manual Scale 0
3 Excell Precision FM User manual Scale 5
4 Excell Precision www.excell.com.tw/excell_en/uploads/product/200712... User manual Scale 30
5 Excell Precision Weighing User manual Scale 4
6 Excell Precision WEIGHING S User manual Scale 8
7 A&D Ej Series Compact Balance EJ-1500 User manual Scale 17
8 A&D A & D Analytical Balance GH-120/GH-200/GH-300/GH-202/GH-252 User manual Scale 13
9 A&D Ej Series Compact Balance EJ-440 User manual Scale 0
10 A&D FG-150KAL User manual Scale 1
11 A&D Ej Series Compact Balance EJ-2000 User manual Scale 2
12 A&D Ej Series Compact Balance EJ-4100 User manual Scale 5
13 A&D Ej Series Compact Balance EJ-120 User manual Scale 2
14 A&D Ej Series Compact Balance EJ-6100 User manual Scale 5
15 A&D FG-150KBM User manual Scale 0