A&D HV-60KV-WP user manual

User manual for the device A&D HV-60KV-WP

Device: A&D HV-60KV-WP
Category: Scale
Manufacturer: A&D
Size: 2.43 MB
Added : 9/23/2013
Number of pages: 72
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for A&D HV-60KV-WP. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with A&D HV-60KV-WP.

For your convenience

If looking through the A&D HV-60KV-WP user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual A&D HV-60KV-WP on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual A&D HV-60KV-WP to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
A&D HV-60KV-WP User manual - Online PDF
Advertisement
« Page 1 of 72 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual A&D HV-60KV-WP but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to A&D HV-60KV-WP. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Waterproof Digital Platform Scale
HV-15KV-WP
HV-60KV-WP
HV-200KV-WP
HW-10KV-WP
HW-60KV-WP
HW-100KV-WP
HW-200KV-WP
WM : PD4000211A

Summary of the content on the page No. 2

This is a hazard alert mark. This mark informs you about the operation of the product. Note This manual is subject to change without notice at any time to improve the product. No part of this manual may be photocopied, reproduced, or translated into another language without the prior written consent of the A&D Company. Product specifications are subject to change without any obligation on the part of the manufacture.

Summary of the content on the page No. 3

Contents 1. Compliance........................................................................................ 3 1.1.1. Compliance with FCC rules....................................................... 3 1.1.2. Classification of protection provided by enclosures................... 3 2. Outline and Features ......................................................................... 4 3. Unpacking.......................................................................................... 5 3.1. Accesso

Summary of the content on the page No. 4

13.1. Preparation (Setting Parameters)................................................ 37 13.2. Operation and Performance (Examples) ..................................... 38 14. Calibration (Adjusting the Scale)...................................................... 39 14.1.1. The Gravity Acceleration Table ............................................... 40 14.2. The Complete Calibration Procedure .......................................... 41 14.2.1. Gravity Acceleration Correction...............

Summary of the content on the page No. 5

1. 1. 1. 1. Compliance Compliance Compliance Compliance 1.1.1. 1.1.1. Com Comp pliance w liance wiith FCC th FCC rule rules s 1.1.1. 1.1.1.Com Comp pliance w liance wiith FCC th FCC rule rules s Please note that this equipment generates, uses and can radiate radio frequency energy. This equipment has been tested and has been found to comply with the limits of a Class A computing device pursuant to Subpart J of Part 15 of FCC rules. These rules are designed to provide reasonable protection again

Summary of the content on the page No. 6

2. 2. 2. 2. O O O Ou u u utlin tlin tlin tline an e an e an e and F d F d F d Fe e e eatur atur atur ature e e es s s s These scales are designed to comply with IP-65 of IEC 529 The HV-WP series is a platform scale with 1/3000 resolution, and has a "triple weighing range" function to select the weighing range. The HW-WP series is a platform scale with 1/10000 resolution. The scales have a fluorescent display so the weighing value can be read in dim light. This type uses the AC power line as a po

Summary of the content on the page No. 7

3. 3. 3. 3. Unp Unp Unp Unpacki acki acki ackin n n ng g g g 3. Unpacking HV-WP/HW-WP Series Page 5

Summary of the content on the page No. 8

3.1. 3.1. Access Accessori orie es and s and Opti Options li ons list st 3.1. 3.1. Access Accessori orie es and s and Opti Options li ons list st Accessories for the HV-WP series and HW-WP series Products Accessories A HV-15KV-WP A Instruction manual HW-10KV-WP A HV-60KV-WP A HV-200KV-WP 3mm Allen wrench HW-60KV-WP A Instruction manual HW-100KV-WP A HW-200KV-WP Options List Cable or option name Accessories A A OP-02 5m extension loadcell cable Tapping screw M4x10 A OP-03 RS-232C interface/ Relay

Summary of the content on the page No. 9

4. 4. 4. 4. Caution Caution Caution Caution 4.1. 4.1. 4.1. 4.1. P P P Pr r r recautions for Insta ecautions for Insta ecautions for Insta ecautions for Installllling ling ling ling the Scale the Scale the Scale the Scale Ground the scale, so that the user will not be subjected to an electric shock. Do not handle the Main power cord with wet hands. The AC plug is not water-resistant. Install it in an area where it does not get wet. Do not install the scale where there is flammable or corrosive ga

Summary of the content on the page No. 10

5. 5. 5. 5. Inst Inst Inst Installing alling alling alling the S the S the S the Sc c c cale ale ale ale This procedure includes all of the steps for installing the HV-WP series and HW-WP series. Therefore, on some products, there are some unnecessary steps. Step 1 Connect the indicator unit to the pole with the accesory knobs and rubber washers. Step 2 Take the base unit and pole out, taking care that the load-cell cable is not pulled. Step 3 Put the weighing pan on the base unit. Step 4 Insert

Summary of the content on the page No. 11

5.1. 5.1. 5.1. 5.1. Remov Remov Remov Removiiiing the ng the ng the ng the pole pole pole pole Caution Remove the main power plug from the receptacle before removing the pole. When removing the loadcell cable, do not pull the loadcell cable connector forcibly and do not pull on the wires of the cable. Do not bend the cable forcibly. Avoid dust, static electricity and high humidity (or drops) because the inside of the indicator unit is very sensitive. Procedure Step 1 Remove the power plug from t

Summary of the content on the page No. 12

Step 8 Removing the pole base from the base unit, requires the following allen wrench. HV-15KV-WP, HV-200KV-WP, HV-60KV-WP, HW-100KV-WP, HW-10KV-WP, HW-200KV-WP HW-60KV-WP 5mm Allen wrench 6mm Allen wrench Step 9 Wind the cable through the ferrite core two times. Affix the cable to the rear cover using the cable clamp. Step 10 Connect the cable to the connnector. Close the rear cover. Step 11 Confirm the accuracy of the scale. 5. 1. Removing the ploe Page 10 HV-WP/HW-WP Series

Summary of the content on the page No. 13

6. 6. 6. 6. Na Na Na Name me me mes s s s 6.Names HV-WP/HW-WP Series Page 11

Summary of the content on the page No. 14

6.1. 6.1. 6.1. 6.1. Display and S Display and S Display and S Display and Sy y y ymbols mbols mbols mbols Display and Symbols Meaning A A Stability mark. When the current weighing value is stable, this mark is A displayed, indicating a condition where the value is A readable. A A Zero point mark. A With nothing on the weighing pan and pressing the ZERO switch, this mark is displayed. The zero point is a A fundamental starting point to weigh anything. A A Net mark. Pressing the TARE switch,

Summary of the content on the page No. 15

Display and Symbols Meaning A A Example. Storing the unit mass of the counting mode. A This is a display of zero point for the counting mode and A uses 20 pieces for the registration. A A Example. Storing the unit mass of the counting mode. A The sign "-" means "weighing value is not zero". A Sample number is 10 pieces. A A Example. Percentage mode. A This mode uses the registered 100% mass, and converts A the weighing value to a percentage. The unit is % . A A Example. Display of the function

Summary of the content on the page No. 16

Display and Symbols Meaning A A An error where the weighing value is unstable due to A drift, vibration or other, when turning on the scale. Check around the weighing pan. A Check the connection of load cell cable. A A Remove anything that may be on the weighing pan. Check around weighing pan. A Perform zero point calibration of the scale. A A Error indication. A Refer to "19 Maintenance". A A Accumulated data count. A A Total mass value of the accumulated data. A A Comparator function, display

Summary of the content on the page No. 17

Display and Symbols Meaning A A Set switch. Turns the comparator on/off. (Refer to f6 ) A Counting mode, it is used to enter the mode to store the A unit mass. A Percentage mode, it is used to enter the mode to store the A 100% mass. A The full/dribble batch function, it is used as a start switch. For the preset tare and selecting a calibration mass, it is A used to select a figure. A A Mode switch. Changing the current unit. A While setting modes, this switch is used for " storing a A parameter

Summary of the content on the page No. 18

7. 7. 7. 7. B B B Ba a a asi si si sic Ope c Ope c Ope c Oper r r ration ation ation ation 7.1. 7.1. 7.1. 7.1. Tu Tu Tu Turing ring ring ring the the the the Sc Sc Sc Scale on/off and Weighing ale on/off and Weighing ale on/off and Weighing ale on/off and Weighing Step 1 Ground the scale using the earth terminal. Step 2 Place nothing on the weighing pan. Step 3 Confirm that local voltage and receptacle type adapt to your scale. Step 4 The scale turns on/off using the ON/OFF switch alternately.

Summary of the content on the page No. 19

7.2. 7.2. 7.2. 7.2. Tare Tare Tare Tare (A (A (A (And nd nd nd Ne Ne Ne Net t t t Di Di Di Disp sp sp splay) lay) lay) lay) "Tare" is used to cancel the mass of a container, receptacle, case, bag, etc. which is put on the weighing pan to contain the item to be weighed. Caution Using a tare value reduces the weighing range. The current tare value is reset by pressing the ZERO switch or turning the scale off. (Reset value is zero.) The preset tare value must be within the minimum weighing range

Summary of the content on the page No. 20

7.3. 7.3. 7.3. 7.3. We We We Weighing ighing ighing ighing Ran Ran Ran Rang g g ge f e f e f e fo o o or r r r the HV- the the the HV- HV- HV-W W W WP series P series P series P series This is the function to select a weighing range for the HV-WP series. The mass value is displayed within a selected range. There is the automatic range (f2 0) and manual range (f2 1) using the RANGE switch. Operation and Performance Function table Meaning and purpose A A Automatic range The weighing range change


Alternative user manuals
# User manual Category Download
1 A&D Ej Series Compact Balance EJ-1500 User manual Scale 17
2 A&D A & D Analytical Balance GH-120/GH-200/GH-300/GH-202/GH-252 User manual Scale 13
3 A&D Ej Series Compact Balance EJ-440 User manual Scale 0
4 A&D FG-150KAL User manual Scale 1
5 A&D Ej Series Compact Balance EJ-2000 User manual Scale 2
6 A&D Ej Series Compact Balance EJ-4100 User manual Scale 5
7 A&D Ej Series Compact Balance EJ-120 User manual Scale 2
8 A&D Ej Series Compact Balance EJ-6100 User manual Scale 5
9 A&D FG-150KBM User manual Scale 0
10 A&D GR Series GR-300 User manual Scale 11
11 A&D GR Series GR-120 User manual Scale 12
12 A&D FG-60KAM User manual Scale 3
13 A&D FS-30Ki User manual Scale 7
14 A&D FG-60KAL User manual Scale 13
15 A&D HC-30Ki User manual Scale 12
16 A&D Ej Series Compact Balance EJ-1500 User manual Scale 17
17 A&D A & D Analytical Balance GH-120/GH-200/GH-300/GH-202/GH-252 User manual Scale 13
18 A&D Ej Series Compact Balance EJ-440 User manual Scale 0
19 A&D FG-150KAL User manual Scale 1
20 A&D Ej Series Compact Balance EJ-2000 User manual Scale 2