A&D UC-321PBT-C user manual

User manual for the device A&D UC-321PBT-C

Device: A&D UC-321PBT-C
Category: Scale
Manufacturer: A&D
Size: 0.31 MB
Added : 5/10/2014
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for A&D UC-321PBT-C. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with A&D UC-321PBT-C.

For your convenience

If looking through the A&D UC-321PBT-C user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual A&D UC-321PBT-C on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual A&D UC-321PBT-C to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
A&D UC-321PBT-C User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual A&D UC-321PBT-C but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to A&D UC-321PBT-C. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1






Precision Health Scale





UC-321PBT-C

Instruction Manual






1WMPD4001968B

Summary of the content on the page No. 2

Contents Before Use Precautions --------------------------------------------------------------------------------------1 Scale Components ------------------------------------------------------------------------------ 2 Display Symbols --------------------------------------------------------------------------------- 3 Installing (or Replacing) Batteries ---------------------------------------------------------- 3 Pairing The PBT-C Series Device With a Continua-Compliant Manager ---------- 4

Summary of the content on the page No. 3

Scale Components Display Back Ready/Complete Symbol Low Battery Indicator Slide Switch Front Battery Compartment Measurement Switch The following measurements can be selected by the slide switch and are classified into two categories - WEIGHT A and WEIGHT B. Within WEIGHT A and WEIGHT B, you have a choice to select and have your weight displayed in kg or lb. Use the WEIGHT B category to enable the radio to send measurement results.

Summary of the content on the page No. 4

Display Symbols Ready/Complete symbol. This symbol is displayed when the measurement display is stable. Low battery indicator. If this symbol is displayed, replace all four batteries with new ones. Installing (or Replacing) Batteries Caution Insert each battery with its positive (+) and negative (-) terminals properly aligned with the corresponding symbols in the battery compartment. Improper installation of the batteries may cause battery leakage. Replace all four batte

Summary of the content on the page No. 5

Pairing The PBT-C Series Device With a Continua-Compliant Manager Model UC-321PBT-C is a PBT-C series device. PBT-C series devices are designed to be connected only with Continua Managers. To pair the device with a Manager, please follow these steps: 1. Remove the four AA batteries from the device. 2. Discharge the device completely by trying to take a measurement. Press the “Measurement” switch, tap the toe switch, or tap the surface of the device as appropriate. Note: the measureme

Summary of the content on the page No. 6

Basic Measurement Measuring Your Weight Set the slide switch 1. Set the slide switch to the correct mode. to the correct mode Example: Set the slide switch to [WEIGHT B]. Press the measurement switch 2. Press the measurement switch gently. All display segments are displayed for several seconds. Ready/Complete symbol 3. Wait until the symbol is displayed. Wait until “0.0 kg /0.0 lb” and the Ready/Complete symbol are displayed. Note: If “0.0 kg /0.0 lb” and the Rea

Summary of the content on the page No. 7

Basic Measurement Measuring an Infant or Small Animal Set the slide switch to the correct mode 1. Set the slide switch to the correct mode. Example: Set the slide switch to [WEIGHT B]. Press the measurement switch Step on the scale 2. Press the measurement switch gently and step on the scale. All display segments are displayed for several seconds. Step on the scale without any baby Ready/Complete symbol or animal in your arms before “0.0 kg /0.0 lb” is displayed. kg 3

Summary of the content on the page No. 8

Measuring Your Weight on a Carpet Place the scale on a solid level surface, such as tile, wood, or laminate flooring. If the scale must be used on a carpet, be sure to attach the plastic add-on feet. Steps for Attaching the Add-on Feet 1. Each add-on foot has two pins. Match those pins to the holes on the scale leg and insert firmly. 2. Attach add-on feet on all four legs. Notes Please be careful not to fall when using the add-on feet. We recommend using this scale on a sol

Summary of the content on the page No. 9

Specifications Digital display Liquid crystal display, 25 mm character height Maximum capacity 200 kg / 450 lb Minimum display 0.1 kg / 0.2 lb Wireless communication WML-40AH (Mitsumi Electronics Co. Ltd.) Bluetooth Ver.2.1 Class 1 HDP Continua certified Power source Four type AA batteries (R6P or LR6, 1.5 volt x 4) Battery life Approximately 1000 measurements Accessories Add-on feet (4), Instruction manual, batteries(4) Specifications are subject to change without prior noti

Summary of the content on the page No. 10

Transmitting Data to a Continua Manager Measurement results will be automatically transmitted to the paired Manager at each measurement. In the case of unsuccessful transmission, the device stores the last 25 measurements in memory. The device will send all of the data at the next successful connection and clear memory. Before Requesting Service Problems Corrective Action Nothing is displayed by pressing the Check the battery installation. measurement switch. Replace all four batte

Summary of the content on the page No. 11

MEMO 10

Summary of the content on the page No. 12

A&D Company, Limited 1-243 Asahi, Kitamoto-shi, Saitama 364-8585 JAPAN Telephone: [81] (48) 593-1111 Fax: [81] (48) 593-1119 A&D INSTRUMENTS LTD. Unit 24/26 Blacklands Way, Abingdon Business Park, Abingdon, Oxfordshire OX14 1DY United Kingdom Telephone: [44] (1235) 550420 Fax: [44] (1235) 550485 A&D Australasia Pty Ltd. 32 Dew Street, Thebarton, South Australia 5031 AUSTRALIA Telephone: [61] (8) 8301-8100 Fax


Alternative user manuals
# User manual Category Download
1 A&D Ej Series Compact Balance EJ-1500 User manual Scale 17
2 A&D A & D Analytical Balance GH-120/GH-200/GH-300/GH-202/GH-252 User manual Scale 13
3 A&D Ej Series Compact Balance EJ-440 User manual Scale 0
4 A&D FG-150KAL User manual Scale 1
5 A&D Ej Series Compact Balance EJ-2000 User manual Scale 2
6 A&D Ej Series Compact Balance EJ-4100 User manual Scale 5
7 A&D Ej Series Compact Balance EJ-120 User manual Scale 2
8 A&D Ej Series Compact Balance EJ-6100 User manual Scale 5
9 A&D FG-150KBM User manual Scale 0
10 A&D GR Series GR-300 User manual Scale 11
11 A&D GR Series GR-120 User manual Scale 12
12 A&D FG-60KAM User manual Scale 3
13 A&D FS-30Ki User manual Scale 7
14 A&D FG-60KAL User manual Scale 13
15 A&D HC-30Ki User manual Scale 12
16 A&D Ej Series Compact Balance EJ-1500 User manual Scale 17
17 A&D A & D Analytical Balance GH-120/GH-200/GH-300/GH-202/GH-252 User manual Scale 13
18 A&D Ej Series Compact Balance EJ-440 User manual Scale 0
19 A&D FG-150KAL User manual Scale 1
20 A&D Ej Series Compact Balance EJ-2000 User manual Scale 2