A&D SW-15KS user manual

User manual for the device A&D SW-15KS

Device: A&D SW-15KS
Category: Scale
Manufacturer: A&D
Size: 1.22 MB
Added : 5/10/2014
Number of pages: 46
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for A&D SW-15KS. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with A&D SW-15KS.

For your convenience

If looking through the A&D SW-15KS user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual A&D SW-15KS on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual A&D SW-15KS to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
A&D SW-15KS User manual - Online PDF
Advertisement
« Page 1 of 46 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual A&D SW-15KS but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to A&D SW-15KS. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



SW Series
SW Series

Super Wash Down Scales
Super Wash Down Scales

SW-6KS / SW-15KS
SW-15KM / SW-30KM / SW-60KM / SW-150KM
SW-60KL / SW-150KL






















1WMPD4002080

Summary of the content on the page No. 2

© 2010 A&D Company, Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated into any language in any form by any means without the written permission of A&D Company, Limited. The contents of this manual and the specifications of the instrument covered by this manual are subject to change for improvement without notice.

Summary of the content on the page No. 3

CONTENTS 1. COMPLIANCE ..................................................................................................... 3 2. INTRODUCTION .................................................................................................. 4 3. FEATURES........................................................................................................... 4 4. PRECAUTIONS.................................................................................................... 5 4.1. Instal

Summary of the content on the page No. 4

13. OPTIONS ......................................................................................................... 25 13.1. Using the OP-02 SLA battery ................................................................ 25 13.1.1. Installing the battery.................................................................... 25 13.1.2. Charging the battery ................................................................... 26 13.2. OP-03 RS-232C / RELAY OUTPUT ..................................

Summary of the content on the page No. 5

1. COMPLIANCE Compliance with FCC rules Please note that this equipment generates, uses and can radiate radio frequency energy. This equipment has been tested and has been found to comply with the limits of a Class A computing device pursuant to Subpart J of Part 15 of FCC rules. These rules are designed to provide reasonable protection against interference when equipment is operated in a commercial environment. If this unit is operated in a residential area it might cause some interfere

Summary of the content on the page No. 6

2. INTRODUCTION This manual describes how the SW Series Super Wash Down Scales work and how to get the most out of them in terms of performance. Please read this manual completely before using the scale. 3. FEATURES The SW Series Super Wash Down Scales have the following features: Dust-tight and water-tight construction, complying with IP69K. The weighing platforms and weighing pans are made of stainless steel (SUS304). The weighing platforms are designed for easy cleanin

Summary of the content on the page No. 7

4. PRECAUTIONS 4.1. Installing the scale Caution • Ground the scale so that the user will not be subject to an electric shock. • Do not handle the AC power cable with wet hands. • The AC plug is not water-resistant. Use an electrical outlet located at a place where the plug will not get wet. • Do not handle the cables carelessly. • Do not install the scale where flammable or corrosive gas is present. Consider the following conditions to get the most from your scale. Install the sc

Summary of the content on the page No. 8

5. UNPACKING When unpacking, check whether all of the following items are included: Instruction manual SW series scale The scale components are different depending on the type of scale. With a display pole (no display stand) With a display stand (no display pole) With no display pole or display stand 6

Summary of the content on the page No. 9

6. DESCRIPTION OF EACH PART Display Display pole AC power cable Spirit level Pole support foot Weighing pan (The above illustration is for scales with a display pole.) Leveling foot Display rear side Display knobs Display knobs Display stand (The above illustration is (The above illustration is for scales with a display pole.) scales with a display stand.) 7

Summary of the content on the page No. 10

6.1. Display and symbols Display LED display STABLE indicator NET indicator LO OK HI pcs g STABLE Weighing NET kg units ZERO indicator ZERO oz lb ON/OFF switch ON/OFF SAMPLE PRINT UNITS ZERO TARE SAMPLE switch PRINT switch ZERO switch TARE switch UNITS switch Symbols Symbol Description STABLE ○ Turns on when the weight value is stable. Turns on when the NET weight is displayed. NET ○ (The tare operation is in progress.) ZERO ○ T

Summary of the content on the page No. 11

6.2. Switches The switches are touch-sensitive. Three levels of switch sensitivity are available and can be set in the function setting “key“. When set to “key 2 “ (High), the switches can be operated with a gloved finger. Switch Description ON/OFF switch Turns the power ON or OFF. When turned ON, the scale will be automatically set to zero (power-on zero). To turn the power OFF, press and hold the switch. Note: If pressing the switch does not turn the power ON immediately, keep

Summary of the content on the page No. 12

7. SETTING UP 7.1. Attaching the display pole to the base Lower part of 2 SW-M / L series with a display pole the display pole 1. Remove the weighing pan from the base. 2. Remove the 4 screws from the lower part of the display pole. 4 3. Insert the display pole under the base while pulling out the cable into the base 3. Pull out the cable and align the cable opening positions of Base the pole and the base. (See “3” in the 3. Insert illustration.) Do not pull the cable forcibl

Summary of the content on the page No. 13

7.2. Installing the scale 1. Select the place for installing the scale. Refer to “4. PRECAUTIONS”. 2. Adjust the level of the base, using the spirit level and leveling feet. Confirm that the bubble is in the center of the level. SW type with a display pole has an extra foot at the bottom of the pole. Adjust this foot to touch the floor after adjusting the level of the base. Leveling foot Spirit level The size and shape depends on the scale model. 3. Adjust the

Summary of the content on the page No. 14

8. BASIC OPERATION 8.1. Turning the power ON and OFF 1. Press the ON/OFF switch to turn the power ON. All the display symbols appear and the scale waits for the weight value to become stable. When the optional sealed lead acid (SLA) battery (OP-02) is used: After all the display symbols appear, the battery capacity status is displayed for about 1.5 seconds as shown below. Level Display Battery capacity status 1 Full capacity “bat ooo” 2 “bat _oo” 3 “bat __o” 4 No capacit

Summary of the content on the page No. 15

8.2. Selecting a weighing unit In the weighing mode, press the UNITS switch to select a weighing unit. Each time the UNITS switch is pressed, the unit changes as shown below. kg or g Ib oz Ib-oz pcs Using the function setting “Ut-g”, “kg” and “g” can be switched. Ut-g 0 : To display “kg”. Ut-g 1 : To display “g”. Note: For the SW-60K / 150K, the function setting “Ut-g” is not available and only “kg” is displayed. 8.3. Basic weighing operation Container 1.

Summary of the content on the page No. 16

8.4. Weight display resolution The weight display resolution is a ratio of the minimum display to the weighing capacity. The SW series has three types of weight display resolution, as shown below. Normal: 1/3,000 High: 1/6,000 or 1/7,500 (depending on the weighing capacity) Maximum 1/12,000 or 1/15,000 (depending on the weighing capacity The factory setting is the high resolution. Select the resolution that suits your own application by the function setting “re5o”.

Summary of the content on the page No. 17

9. COUNTING MODE Determines a unit weight (the weight of one piece) from a known sample quantity, and calculates how many pieces are on the weighing pan using the unit weight. The unit weight is maintained even if the power is turned OFF. Press 1. Press the UNITS switch to select “pcs”. (“pcs” = pieces) ZERO 2. Press the SAMPLE switch to enter the Press Number of sample unit weight storing mode. samples The numerical value on the left indicates the number of samples. ZERO

Summary of the content on the page No. 18

10. COMPARATOR Five-level and three-level comparators are available. The five-level comparator mode uses four comparator values to compare the weight value and outputs results in five levels of LOLO, LO, OK, HI and HIHI. The three-level comparator mode uses two comparator values (upper and lower limit values) to compare the weight value and outputs results in three levels of LO, OK and HI. The results are output using LEDs (yellow / green / red). When the optional comparator relay outpu

Summary of the content on the page No. 19

Three-level comparator mode Results Comparison formula LED display Displayed value < LO limit value LO (Or over in the negative value) ( Red LED on) OK LO limit value ≤ Displayed value ≤ HI limit value ( Green LED on)) HI limit value < Displayed value HI (Or over in the positive value) ( Red LED on) LO limit value = Lower limit value HI limit value = Upper limit value The comparator values are common to the weighing and counting mode. Ignore the decimal point when set

Summary of the content on the page No. 20

10.2. Entering the comparator values 1. In the weighing mode, press and hold the SAMPLE switch to enter the comparator value setting mode. 2. Enter the comparator values using the following switches. UNITS To shift the blinking digit to the right. PRINT To increase the value of the blinking digit by one. SAMPLE To switch the polarity. Each time the switch is pressed, “-“ is turned on and off at the left- most digit. When on, the value is negative. TARE To confirm and sto


Alternative user manuals
# User manual Category Download
1 A&D Ej Series Compact Balance EJ-1500 User manual Scale 17
2 A&D A & D Analytical Balance GH-120/GH-200/GH-300/GH-202/GH-252 User manual Scale 13
3 A&D Ej Series Compact Balance EJ-440 User manual Scale 0
4 A&D FG-150KAL User manual Scale 1
5 A&D Ej Series Compact Balance EJ-2000 User manual Scale 2
6 A&D Ej Series Compact Balance EJ-4100 User manual Scale 5
7 A&D Ej Series Compact Balance EJ-120 User manual Scale 2
8 A&D Ej Series Compact Balance EJ-6100 User manual Scale 5
9 A&D FG-150KBM User manual Scale 0
10 A&D GR Series GR-300 User manual Scale 11
11 A&D GR Series GR-120 User manual Scale 12
12 A&D FG-60KAM User manual Scale 3
13 A&D FS-30Ki User manual Scale 7
14 A&D FG-60KAL User manual Scale 13
15 A&D HC-30Ki User manual Scale 12
16 A&D Ej Series Compact Balance EJ-1500 User manual Scale 17
17 A&D A & D Analytical Balance GH-120/GH-200/GH-300/GH-202/GH-252 User manual Scale 13
18 A&D Ej Series Compact Balance EJ-440 User manual Scale 0
19 A&D FG-150KAL User manual Scale 1
20 A&D Ej Series Compact Balance EJ-2000 User manual Scale 2