Adam Equipment CBW 6 user manual

User manual for the device Adam Equipment CBW 6

Device: Adam Equipment CBW 6
Category: Postal Equipment
Manufacturer: Adam Equipment
Size: 0.61 MB
Added : 3/17/2013
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Adam Equipment CBW 6. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Adam Equipment CBW 6.

For your convenience

If looking through the Adam Equipment CBW 6 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Adam Equipment CBW 6 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Adam Equipment CBW 6 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Adam Equipment CBW 6 User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Adam Equipment CBW 6 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Adam Equipment CBW 6. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



Adam Equipment







CBW SERIES
(P.N. 4276, Rev. B9, May 2007)






Software rev.: 1.2- 2.04
(For CBW 6H / 12aH, rev.:1.4-3.00)









© Adam Equipment Company 2007

Summary of the content on the page No. 2

© Adam Equipment Company 2007

Summary of the content on the page No. 3

CONTENTS 1.0 INTRODUCTION............................................................................................................2 2.0 SPECIFICATIONS .........................................................................................................3 3.0 INSTALLATION..............................................................................................................5 3.1 LOCATING THE SCALE ........................................................................

Summary of the content on the page No. 4

1.0 INTRODUCTION • The CBW series of scales provide an accurate, fast and versatile series of general purpose weighing scales with counting, % weighing and check-weighing functions. • There are 2 series of scales - CBW scales which use kilograms as the default unit and the CBWa range of scales have changeable units from pounds to kilograms. The scales in these series share the same functions except the CBWa series have the ability to change the weighing units. • There are 6 mo

Summary of the content on the page No. 5

2.0 SPECIFICATIONS CBW SERIES Model # CBW 3 CBW 6H CBW 6 CBW 15 CBW 30 CBW 45 Maximum Capacity 3 kg 6 kg 6 kg 15 kg 30 kg 45 kg Readability 0.1 g 0.1 g 0.2 g 0.5 g 1 g 2 g Tare Range -3 kg -6 kg -6 kg -10 kg -30 kg -45 kg Repeatability (Std. 0.1 g 0.1 g 0.2 g 0.5 g 1 g 2 g Dev.) Linearity ± 0.2 g 0.2 g 0.4 g 1 g 2 g 4 g Units of measure Kg, g CBWa SERIES Model: CBW-6a UNITS OF MAXIMUM TARE READABILITY REPEATABILITY LINEARITY MEASURE CAPACITY RANGE 0.1 g 0.1 g

Summary of the content on the page No. 6

Model: CBW-35a UNITS OF MAXIMUM TARE READABILITY REPEATABILIT LINEARITY MEASURE CAPACITY RANGE Y -10000.0 g 0.5 g 0.5 g 1 g Grams 15000.0 g -10 kg 0.0005 kg 0.0005 kg 0.001 kg Kilograms 15.0000 kg Pounds 35.000 lb -35 lb 0.001 lb 0.001 lb 0.002 lb -35 lb 0.0 oz 0.1 oz 0.1 oz 0.1 oz Pounds/Ounces 35 lb 0.0 oz Model: CBW-65a UNITS OF MAXIMUM TARE READABILITY REPEATABILIT LINEARITY Y MEASURE CAPACITY RANGE Grams 30000 g -30000 g 1 g 1 g 2 g -30 kg 0.001 kg 0.001 kg 0.002 kg Kilogram

Summary of the content on the page No. 7

3.0 INSTALLATION 3.1 LOCATING THE SCALE • The scales should not be placed in a location that will reduce the accuracy. • Avoid extremes of temperature. Do not place in direct sunlight or near air conditioning vents. • Avoid unsuitable tables. The table or floor must be rigid and not vibrate. • Avoid unstable power sources. Do not use near large users of electricity such as welding equipment or large motors. • Do not place near vibrating machinery. • Avoid

Summary of the content on the page No. 8

the level and the scale is supported by all four feet. • Attach the power supply cable to the connector on the bottom of the scale. Plug in the power supply module. The power switch is located on the base on the right side of the scale. • The scale will first display the model number (CBW 30- where 30 denotes the capacity of the scale in kg), followed by the revision numbers (1.2-2.03 where 1.2 is the current hardware revision number of the main circuit board and 2.03 is the current

Summary of the content on the page No. 9

It sets the limits for check A secondary function [Limit] weighing and allows setting of is available to move the active digit either the low limit or the high to the right when setting values for limit or both. parameters or other functions. It enters the percent weighing A secondary function is [%] function. Allows the weight, available to move the active digit to unit weight, and count to be the left when setting values for seen when parts counting. paramete

Summary of the content on the page No. 10

5.0 DISPLAYS The LCD display will show a value and a unit to the right of the digits. Other labels are TARE, GROSS, ZERO, / O (Stable) and (Low battery). 6.0 OPERATION 6.1 ZEROING THE DISPLAY • You can press the [Zero/Enter] key at any time to set the zero point from which all other weighing and counting is measured. This will usually be necessary when the platform is empty. When the zero point is obtained the display will show the indicator f

Summary of the content on the page No. 11

6.2 TARING • Zero the scale by pressing [Zero/Enter]. The zero indicator will be on. Place a container on the pan and its weight will be displayed. • Press [Tare] to tare the scale. The weight that was displayed is stored as the tare value and it is subtracted from the display, leaving zero on the display. The "TARE" indicator will be on and the “GROSS” indicator will be off. As product is added only the weight of the product will be shown. The scale could be tared a second time if

Summary of the content on the page No. 12

6.5 PARTS COUNTING • Before beginning, tare the weight of any container that will be used, leaving the empty container on the scale. • For CBW- 6H /12aH, place the sample first and then press the [Func] key. For all other models first press the [Func] key to begin. The scale will show "P 10" asking for a sample size of 10 parts. Change the sample size by pressing the [Tare/ ] key. The display will cycle through the options: 10, 20, 50, 100, 200 and back to 10. • Place the num

Summary of the content on the page No. 13

6.6.1 Setting up Check-weighing while weighing • Press [Limit]. It will show the current High Limit with the left most digit flashing and the HI symbol on the left of the display. • To select the digit to be changed press [Limit/ ] or [%/ ]. Use [Tare/ ] to increment the flashing digit. When the desired value is shown press [Zero/Enter] to accept the value. If you want to reset the value to zero, press the [Func/C] key to clear the value. • After pressing [Zero/Enter] the dis

Summary of the content on the page No. 14

6.6.2 Setting up Checkweighing while Parts Counting • Checkweighing facility can be set up for Parts Counting by entering values as Low and High Limits to be keyed in by the user. The limits are displayed in PCS. • Press [Func] to enter the Parts Counting mode. Press [Zero/Enter] to fix a sample size. Press [Limit] and enter the numeric values for high and low limits following the same procedure as stated in the earlier section. NOTE: • The weight must be greater than 20 s

Summary of the content on the page No. 15

6.8 MANUAL ACCUMULATION • When the scale is set to manual accumulation the weight displayed will be stored in memory when the [Print] key is pressed and the weight is stable. • The display will show "ACC 1" and then the total in memory for 2 seconds before returning to normal. The weight will be output to a printer or PC. • Remove the weight, allowing the scale to return to zero and put a second weight on. Press [Print], the display will show "ACC 2" and then show the new

Summary of the content on the page No. 16

6.9 AUTOMATIC ACCUMULATION • When the scale has been set to Automatic Accumulation the value is stored in memory automatically. • Add a weight to the scale. The beeper will sound when the scale is stable indicating the value is accepted. Remove the weight. • The display will show "ACC 1" and then the total in the memory nd before it returns to zero. Adding a 2 weight will repeat the process. • While the weight is on the scale, press the [Print] key to show the values imme

Summary of the content on the page No. 17

To set parameters, press the [Func] and [Print] keys at the same time. 7.1 INCREMENT VALUE • The first parameter on setting the increment value will be displayed as "Inc xx" where xx can be 1, 2, 5 or 10. The first value shown is the default scale increment value. • To change to a different increment value press [Tare/ ]. • Press the [Zero/Enter] key to store the changed value and move to the next parameter. 7.2 CONTROL THE BACKLIGHT • The standard is to have the backli

Summary of the content on the page No. 18

7.4 ACCUMULATION OF DATA IN MEMORY WHEN [PRINT] IS PRESSED • To accumulate weight in the memory when [Print] is pressed, set the scale to "ACC on". • To use the [Print] key to only print the weight without adding it to memory, set to "ACC oFF". • Press [Tare/ ] to change the setting between on and oFF. • Press the [Zero/Enter] key to store the changed setting and move to the next parameter. 7.5 AUTO ZERO RANGE • The auto-zero will automatically set the scale to zer

Summary of the content on the page No. 19

CBWa Scales only: The CBWa scales can change units from kilograms to grams, pounds or pounds/ounces immediately if they are enabled as in the step above. This also allows the scales to be calibrated in either kilograms or pounds and all memory accumulations are in either kilograms or pounds as last selected. When the scales are set to display in other units the accumulation function is still keeping the weight in kilograms (or pounds for the CBWa series) in memory and will use th

Summary of the content on the page No. 20

8.0 BATTERY OPERATION • The scales can be operated from the battery, if desired. The battery life is approximately 70 hours. • When the battery needs charging a symbol on the display will turn on. The battery should be charged when the symbol is on. The scale will still operate for about 10 hours after which it will automatically switch off to protect the battery. • To charge the battery, simply attach the power supply module to the scale and plug in. The scale does not nee


Alternative user manuals
# User manual Category Download
1 Adam Equipment 303669031 revision E4 User manual Postal Equipment 0
2 Adam Equipment 6164 User manual Postal Equipment 0
3 Adam Equipment 9384 revision A1 User manual Postal Equipment 0
4 Adam Equipment 8509 User manual Postal Equipment 0
5 Adam Equipment AZextra-P User manual Postal Equipment 0
6 Adam Equipment 8141 User manual Postal Equipment 0
7 Adam Equipment CBDa User manual Postal Equipment 0
8 Adam Equipment BFW User manual Postal Equipment 3
9 Adam Equipment CBC-M User manual Postal Equipment 0
10 Adam Equipment CBW 15 User manual Postal Equipment 0
11 Adam Equipment CBW 3 User manual Postal Equipment 2
12 Adam Equipment CBW 30 User manual Postal Equipment 5
13 Adam Equipment CBW 45 User manual Postal Equipment 0
14 Adam Equipment CQT1751GR User manual Postal Equipment 0
15 Adam Equipment CRW User manual Postal Equipment 1
16 A&D AD-4212A-100/200/600/1000 User manual Postal Equipment 3
17 A&D AD-4322 MKII User manual Postal Equipment 9
18 A&D AD-4212B-101/102/201/301 User manual Postal Equipment 9
19 Adam Equipment 303669031 revision E4 User manual Postal Equipment 0
20 Adam Equipment 6164 User manual Postal Equipment 0