Adam Equipment GFK 150M user manual

User manual for the device Adam Equipment GFK 150M

Device: Adam Equipment GFK 150M
Category: Building Set
Manufacturer: Adam Equipment
Size: 0.63 MB
Added : 12/4/2013
Number of pages: 68
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Adam Equipment GFK 150M. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Adam Equipment GFK 150M.

For your convenience

If looking through the Adam Equipment GFK 150M user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Adam Equipment GFK 150M on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Adam Equipment GFK 150M to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Adam Equipment GFK 150M User manual - Online PDF
Advertisement
« Page 1 of 68 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Adam Equipment GFK 150M but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Adam Equipment GFK 150M. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


Adam Equipment


GBK and GFK Series
(P.N. 9679, Revision C, June 2010)


Software Rev.
V1.17 GK-H scales for Europe
V2.25 EC Approved scale
V3.32 GK scale for USA
V4.07 GK-H scale for USA
V5.32 GK scales for Europe












© Adam Equipment Company 2010

Summary of the content on the page No. 2

Easy Reference: Model name of the scale: Serial number of the unit: Software revision number (Displayed when power is first turned on): Date of Purchase: Name of the supplier and place: © Adam Equipment Company 2010

Summary of the content on the page No. 3

CONTENTS 1. INTRODUCTION......................................................................................3 2. SPECIFICATIONS ...................................................................................4 3. INSTALLATION.......................................................................................9 3.1. UNPACKING ........................................................................................................ 9 3.2. LOCATING ........................................

Summary of the content on the page No. 4

2 | page © Adam Equipment Company 2010

Summary of the content on the page No. 5

1. INTRODUCTION • The GBK/GFK scales provides an accurate, fast and versatile general purpose weighing scales with parts counting, percent weighing and check-weighing functions. • The GBK/GFK has LEDs to indicate when a weight is below the low limit, between the limits or above the high limit next to the display. These can work in conjunction with an audible alarm for check weighing as well as LCD showing LO, OK and HI. • The GBK/GFK is supplied with a RS-232 bi-directional in

Summary of the content on the page No. 6

2. SPECIFICATIONS GBK Models Model # GBK 8 / GBK 16/ GBK 32 / GBK 60 / GBK 120 / GBK 16a GBK 35a GBK 70a GBK 130a GBK 260a Maximum Capacity 8kg/16lb 16kg/35lb 32kg/70lb 60kg/130lb 120kg/260lb Readability 0.1g/0.0002lb 0.5g/0.001lb 1g/0.002lb 2g/0.005lb 5g/0.01lb Repeatability (Std Dev) 0.2g/0.0004lb 1g/0.002lb 2g/0.004lb 4g/0.01lb 10g/0.02lb Linearity + 0.3g/0.0006lb 1g/0.002lb 2g/0.004lb 4g/0.01lb 10g/0.02lb Units of Measure Grams & Kilograms, XXXa also to have Pou

Summary of the content on the page No. 7

GFK Models Model # GFK 75 / GFK 150 / GFK 300 / GFK 600 / GFK 75H / GFK 150H / GFK 165a GFK 330a GFK 660a GFK 1320a GFK165aH GFK330aH Maximum Capacity 75kg / 165lb 150kg / 330lb 300kg / 660lb 600kg / 1320lb 75kg / 165lb 150kg / 330lb Readability 5g / 0.01lb 10g / 0.02lb 20g / 0.05lb 50g / 0.1lb 1g / 0.002lb 2g / 0.005lb Repeatability (Std Dev) 5g / 0.01lb 10g / 0.02lb 20g / 0.05lb 50g / 0.1lb 2g / 0.004lb 4g / 0.01lb Linearity + 10g / 0.02lb 20g / 0.04lb 40g / 0.1lb 100g / 0

Summary of the content on the page No. 8

GBK-M Models Model # GBK 6M GBK 15M GBK 30M GBK 60M GBK 150M Maximum 6kg 15kg 30kg 60kg 150kg Capacity Readability 0.002kg 0.005kg 0.01kg 0.02kg 0.05kg Units of Measure Kilograms only Stabilization 2-3 Secs Time Operating -10°C to +40°C / +14°F to +104°F Temperature 230VAC 50/60Hz. Power Supply External Calibration User Selectable Calibration Mass Backlit Green display 25mm with capacity tracker Display Cast Aluminum base, Pantone cool grey painted base, stainless steel gr

Summary of the content on the page No. 9

GFK-M Models Model # GFK 60M GFK 150M GFK 300M Maximum Capacity 60kg 150kg 300kg Readability 0.02kg 0.05kg 0.1kg Units of Measure Kilograms only Stabilization Time 2-3 Secs 2-3 Secs 2-3 Secs -10°C to +40°C / +14°F to +104°F Operating Temperature 230VAC 50/60Hz. Power Supply External Calibration User Selectable Calibration Mass Backlit Green display 25mm with capacity tracker Display Cast Aluminum base, Pantone cool grey painted base, stainless steel grade 304 Balance Housing

Summary of the content on the page No. 10

8 | P a g e © Adam Equipment Company 2010

Summary of the content on the page No. 11

3. INSTALLATION 3.1. UNPACKING The GBK/GFK scales have already been adjusted to work with a platform and have been configured for this application. The platform and indicator have been calibrated as a pair and must be used together . 3.2. LOCATING • The scales should not be placed in a location that will reduce the accuracy. • Avoid extremes of temperature. Do not place in direct sunlight or near air conditioning vents. • Avoid unsuitable tables. The table or floo

Summary of the content on the page No. 12

3.3 SETTING UP THE SCALES • The pillar is attached to the base using a bracket that must be attached to the base frame first using the 4 bolts supplied. The pillar is secured to the bracket using 2 sets of screws. The cable from the base to the indicator module is run through the tube and taken out through the plastic support at the top. Excess cable can be stored within the tube. • The GBK/GFK Series comes with a stainless steel platform packed separately. Place the platform i

Summary of the content on the page No. 13

4. KEYPAD KEYS PRIMARY FUNCTION SECONDARY FUNCTION [Zero] Sets the zero point for all subsequent Escape from any setting menus weighing. The display shows zero. [Tare] It tares the scale and stores the current Accept the set values weight in memory as a tare value, subtracts the tare value from the weight and shows the results. This is the net weight. [Unit] This is used to select the weighing units Allows the weight, unit weight, and from a preset list of available

Summary of the content on the page No. 14

[Low It sets the limits for check weighing and None Limit] allows setting of either the low limit or the high limit or both. & [High Limit] [Lim] It stores and recalls any of 10 preset limits None  [Func] This is used to select percent weighing, RS- None 232 parameters, Operation of the bar graph, RTC settings, User ID and Scale ID. [Count] Enter Parts Counting None. [Print] It is used to print the results to a PC or None printer using the RS-232 interface.

Summary of the content on the page No. 15

5. DISPLAY 5.1. SYMBOLS AND INDICATORS The LCD has unique symbols to indicate the following: The display is at Zero 0 The scale is Stable Net weight- The scale has been tared Net Symbols shown for the units kg / lb Capacity Tracker- A bar graph indicating the proportion of the scale capacity being used by the weight on the platform Low battery bAt LO or The scale is in Percent weighing mode % The scale is in Parts counting mode pcs The scale

Summary of the content on the page No. 16

Next to the LCD are a number of LED’s that show when the weight is below, within or over the limits during check weighing. Weight LED LCD below the low limit Amber LO Within the limits Green OK Above the high limit Red HI NOTE: The LED’s can be set by the user to off, bar, spot or segment mode. See “F3 LED” in section 13.1 The LED can be set to display as a bar, increasing from Low to OK to High, a single spot increasing from Low, OK to High, or as a single bar that chan

Summary of the content on the page No. 17

The Counters are incremented any time the calibration section or the Factory parameters section have been modified. At power on, the display will show the current software revision number followed by the message of the Calibration Count “[AL[nt” then a number i.e. “123”. The number from the counter memory. Then the Parameter Counter message of “PAr[nt” and probably a different number, i.e. “234”. The counters cannot be reset to 0, they will increment until the display can

Summary of the content on the page No. 18

7. BATTERY • The scales can be operated from the rechargeable battery, if desired. The GBK/GFK scales have up to 70 hours battery life before needing to be recharged if the backlight is disabled and the battery is fully charged. • When the battery needs charging a symbol on the display will turn on. The battery should be charged when the symbol is on. The scale will still operate for a period of time after which it will automatically switch off to protect the battery. • To charg

Summary of the content on the page No. 19

10. OPERATION 10.1. ZEROING • You can press the [Zero] key at any time to set the zero point from which all other weighing and counting is measured. This will usually be necessary when the platform is empty. When the zero point is obtained the display will show the zero indicator. • The scale has an automatic re-zeroing function to account for minor drifting or accumulation of material on the platform. However you may need to press [Zero] to re-zero the scale if small amount

Summary of the content on the page No. 20

added to the first one. Again only the weight that is added after taring will be displayed. NOTE: When the container is removed a negative value will be shown. If the scale was tared just before removing the container, this value is the gross weight of the container plus all products which were removed. The zero indicator will also be on as the platform is back to the same condition it was when [Zero] was pressed last. Press [Tare] or [Zero] to remove the tare value and displa


Alternative user manuals
# User manual Category Download
1 Adam Equipment AZplus 30 User manual Building Set 1
2 Adam Equipment GBK 150M User manual Building Set 0
3 Adam Equipment GBK 120 /GBK 260a User manual Building Set 6
4 Adam Equipment GBK 16/GBK 35a User manual Building Set 0
5 Adam Equipment GBK 15M User manual Building Set 1
6 Adam Equipment GBK 60M User manual Building Set 0
7 Adam Equipment AZplus 6 User manual Building Set 0
8 Adam Equipment GBK 30M User manual Building Set 0
9 Adam Equipment AZplus 15 User manual Building Set 0
10 Adam Equipment GBK 60 /GBK 130a User manual Building Set 3
11 Adam Equipment GBK 32 /GBK 70a User manual Building Set 3
12 Adam Equipment GBK 6M User manual Building Set 0
13 Adam Equipment GBK 8 /GBK 16a User manual Building Set 0
14 Adam Equipment GFK 150 /GFK 330a User manual Building Set 3
15 Adam Equipment GFK 150H /GFK330aH User manual Building Set 0
16 A&D HD-05 User manual Building Set 0
17 A&D HD-30K User manual Building Set 6
18 A&D HD-60KB User manual Building Set 0
19 A&D UC-321PL User manual Building Set 0
20 A&D HD-12K User manual Building Set 0