Bayer HealthCare Ascensia Elite XL user manual

User manual for the device Bayer HealthCare Ascensia Elite XL

Device: Bayer HealthCare Ascensia Elite XL
Category: Blood Glucose Meter
Manufacturer: Bayer HealthCare
Size: 1.84 MB
Added : 10/18/2013
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bayer HealthCare Ascensia Elite XL. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bayer HealthCare Ascensia Elite XL.

For your convenience

If looking through the Bayer HealthCare Ascensia Elite XL user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bayer HealthCare Ascensia Elite XL on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bayer HealthCare Ascensia Elite XL to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bayer HealthCare Ascensia Elite XL User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bayer HealthCare Ascensia Elite XL but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bayer HealthCare Ascensia Elite XL. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
THE NEW FACE of Glucometer
Diabetes Care System
USER GUIDE
For Use With

Ascensia ELITE XL
Blood Glucose Meter
Need Help with Reimbursement?
Call Our Bayer Care Help Line: 1-877-787-1912

Summary of the content on the page No. 2

2 The Meter Test slot Test Strip Test Icon end Meter end Button Display ii

Summary of the content on the page No. 3

Testing Materials 2 • Ascensia ELITE™ Test Strip – use for blood or control testing. Insert into Meter before drawing in blood or control sample. test end meter end • Ascensia ELITE™ Check Strip – use to check if the Meter is working properly before running a blood glucose test. • Ascensia ELITE™ Code Strip – use to set the Meter (calibrate) to match the box of Test Strips. ® • MICROLET Adjustable Lancing Device – use for finger ® puncture with a MICROLET Lancet. • NORMAL CONTROL SOLUTION – use

Summary of the content on the page No. 4

The Ascensia ELITE™ XL Diabetes Care System is a blood glucose monitoring system for diabetes management in home or professional use. The system is based on electrode sensor technology. Convenient features of the system are: • Two-step testing process: 1. Insert Test Strip in Meter 2. Touch TEST END to blood • Test results are displayed in 30 seconds. • Meter turns on when inserting a strip and turns off when remov- ing the strip. • Up to 120 test results may be stored in the Meter and can be re

Summary of the content on the page No. 5

Frequently Asked Questions 2 What do I do first? If needed, install batteries and set the time—test the Meter electronics with a Check Strip—code the Meter to match Ascensia ELITE Test Strips—and then run a control test to test the whole system before running a blood glucose test. What does blood glucose monitoring do for me? Blood glucose levels change during the day due to medication, exercise, diet, insulins or hypoglycemics (oral agents) or possibly stress and illness. Blood glucose testing p

Summary of the content on the page No. 6

2 Important Information • The Ascensia ELITE™ XL Blood Glucose Meter has been designed for use with Ascensia ELITE™ Test Strips. The perfor- mance characteristics of the Meter may not be valid for any other brand of Test Strips. The use of other Test Strips may cause erroneous results. Bayer Corporation does not warrant the use of the Ascensia ELITE XL Blood Glucose Meter with any Test Strip other than Ascensia ELITE Test Strips. • Glucose levels below 50 or above 250 mg/dL (below 2.8 or above 1

Summary of the content on the page No. 7

User Guide Contents 2 SECTION PAGE Set Up For Testing 1 Install Batteries 4 2 Set the Alarm, Time and Units 5 3 Check Strip Test 6 4 Code the Meter 7 5 Control Test 8 Testing 6 Blood Glucose Test 11 7 Important to Remember 15 Test Result Management 8 Stored Test Results 17 9 Data Management 18 Taking Care 10 Meter and Test Strip Care 19 11 Meter and Test Strip Problems 21 Technical Support Information 12 Service 25 13 Limitations of the Procedure 27 14 Specifications 28 15 Supplies 29 16 Warranty

Summary of the content on the page No. 8

SECTION 1 Install Batteries Install batteries when the Meter is new if needed. Replace batteries when the Meter displays the battery symbol . 1. Press firmly on “open” arrow and slide forward in the direc- tion of the arrow. The lid releases. 2. Place new batteries into the bat- tery compartment with the “+” side up. Slide lid back into place, lining up with open slots, and close firmly. Test results stored in the memory are not erased when batteries are changed, but time must be reset. NOTE: Two

Summary of the content on the page No. 9

SECTION Set the Alarm, Time and Units 2 Some Meter options may need to be reset when the Meter is new and when batteries are changed. The options may be changed any time to fit your needs. How do I set the Meter? Hold the button for five seconds to place Meter in “set up” mode. Press the button to change item as it flashes (you have five seconds to make a change). Display 1. Press button to switch: Beeper on to beeper off if you wish to turn off the sound. Display 2. Press button to set: • Minute •

Summary of the content on the page No. 10

SECTION 3 Check Strip Test Check your Meter when new or any time after use, to make sure that electronics are working properly. HOW: 1. Remove the Check Strip from the package (save the package). 2. Insert the Check Strip (“check” side up) fully into the Meter until you hear a beep. A full display* shows, followed by another beep and then the Check Strip result. 3. The Check Strip result must be within the range listed on the Check Strip package insert. If not, see the problem solving chart in S

Summary of the content on the page No. 11

SECTION Code the Meter 4 Code the Meter whenever a new box of Test Strips is opened.* This will match the Meter to the Test Strip reactivity. HOW: You will need the Code Strip found in the new box of strips. 1. Tear open the packet found in the new carton of Test Strips and remove the Code Strip (save the packet). 2. Insert the Code Strip into the test slot as shown. A beep sounds and a full display appears briefly. Another beep sounds and the Code Number (for example F-5) appears in the displa

Summary of the content on the page No. 12

SECTION 5 Control Test A Control Test is run to find out if the whole system is working correctly (Test Strip and Meter) and to practice good technique before blood glucose testing. Prepare for the Test: 1. To open the Test Strip foil packet, carefully peel the foil back until the Test Strip is completely exposed (as shown). Save the foil packet. Note: Numbers printed on each Test Strip are manufacturing numbers and are not to be confused with Code Numbers (F#). 2. Holding the round end of the

Summary of the content on the page No. 13

SECTION Control Test 5 Take the Test: 5. Squeeze a small drop of Control Solution onto the inside of the foil packet you saved. 6. Touch and hold the TEST END of the Test Strip to the drop until the Meter beeps (the Control Solution has now been drawn into the Test Strip). The timer begins to count down from 29 seconds. The test result appears with “CONT” in the display (if marked) when the countdown is com- plete. Compare result to range on end flap of Test Strip carton. 7. If you did not mark c

Summary of the content on the page No. 14

SECTION 5 Control Test If you did not mark your control or want to delete the test result, do one of the following options before removing the strip. Remember, after marking or deleting, the test result will then not be a part of the blood glucose test average and will be stored in the memory and displayed with “CONT” or “DEL”. Mark the Result: Hold the button until “CONT” appears at the top of the display. Release the but- ton and “CONT” begins flashing. Remove the Test Strip while “CONT” is flas

Summary of the content on the page No. 15

SECTION Blood Glucose Test 6 What does blood glucose monitoring do for me? Blood glucose levels change during the day due to medication, exercise, diet, insulins or hypoglycemics (oral agents) or possibly stress and illness. Blood glucose testing provides information that will help you understand the changes. This information can help you manage your diabetes to keep your blood sugar levels within your target range. Prepare for the Test: You will need a Microlet Lancing Device and Lancet to stic

Summary of the content on the page No. 16

SECTION 6 Blood Glucose Test Take the Test: You need a Meter and Test Strip. 1. After washing your hands with warm soapy water and drying thoroughly, open a foil packet and remove the Test Strip. 2. With the Meter off, hold the round end and insert the Test Strip fully into the Meter. You will hear a beep. 2. After a full display, the Code Number (F#) and previous test result begin flashing alternately. 3. Press Microlet firmly against puncture site and push button to release. Form a small, round

Summary of the content on the page No. 17

SECTION Blood Glucose Test 6 Note: Multiple Site Testing Consult with your healthcare professional prior to testing from a site other than your fingertips. Blood glucose testing results from sites other than your fingertip could be significantly different. These differences may vary from indi- vidual to individual, and are physiological differences caused by fac- tors such as food intake, health state and medication being used. If you perform testing other than from a fingertip: A. Select a soft, fle

Summary of the content on the page No. 18

SECTION 6 Blood Glucose Test Test Results: After 29 seconds, your test result is displayed. Do not remove strip until results are displayed. Record the test result/date in your Clinilog Diary.* Remove the Test Strip. The Meter turns off and the test result is stored. *If you do not want to store the test result—before remov- ing Test Strip, press the button and hold until “CONT” appears. Release the button and “CONT” begins flashing. Press the button again,“DEL” begins flashing. Remove the Te

Summary of the content on the page No. 19

SECTION Important to Remember 7 DON’T FORGET—when using the Meter: • Insert the Check Strip, Code Strip or Test Strip with a firm motion until it comes to a full stop. • The tab on the strip can no longer be seen if the Test Strip has been inserted fully into the Meter. • The Meter turns off automatically after 3 minutes if strip is left in the Meter. • The Code Number (F#) appearing in the Display must match the number appearing on the: ----- Code Strip ----- Code Strip packet ----- Back of

Summary of the content on the page No. 20

SECTION 7 Important to Remember DON’T FORGET—when using the Meter (cont.): • When the Meter memory is full and a new test result is entered, the oldest result is deleted (i.e., #1). • Teach another person how to use the system, so you will have someone to help if you ever need assistance. DON’T FORGET—when using a Test Strip: • Always check the expiration date on the Test Strip foil packet or carton. If date is passed, replace with unexpired Test Strips. • Use the Test Strip immediately after re


Alternative user manuals
# User manual Category Download
1 Bayer HealthCare Ascensia Contour User manual Blood Glucose Meter 267
2 Bayer HealthCare Breeze 2 User manual Blood Glucose Meter 934
3 Bayer HealthCare Contour TS User manual Blood Glucose Meter 1516
4 Bayer HealthCare Ascensia Contour Blood Glucose Monitoring System User manual Blood Glucose Meter 42
5 Bayer HealthCare MODEL Ascensia Elite User manual Blood Glucose Meter 105
6 Bayer HealthCare CONTOURand Ascensia CONTOURTM Test Strips User manual Blood Glucose Meter 18
7 Bayer HealthCare Elite XL User manual Blood Glucose Meter 30
8 Bayer HealthCare Rapidlab 800 User manual Blood Glucose Meter 11
9 Bayer HealthCare ESPRIT User manual Blood Glucose Meter 22
10 Bayer HealthCare 2 User manual Blood Glucose Meter 1
11 Bayer HealthCare Ascensia BREEZE and Ascensia AUTODISCTM Unique 10-Test Disc User manual Blood Glucose Meter 50
12 A&D UA-1030TCN User manual Blood Glucose Meter 3
13 A&D UA-1030T User manual Blood Glucose Meter 4
14 Abbott Diabetes Care 7115 User manual Blood Glucose Meter 12
15 Abbott Diabetes Care FreeStyle Flash Blood Glucose Monitor User manual Blood Glucose Meter 106
16 Abbott Diabetes Care Blood Glucose Monitoring System ART21258 User manual Blood Glucose Meter 2