Emerson Liebert XDF user manual

User manual for the device Emerson Liebert XDF

Device: Emerson Liebert XDF
Category: Surge Protector
Manufacturer: Emerson
Size: 14.45 MB
Added : 11/23/2013
Number of pages: 60
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson Liebert XDF. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson Liebert XDF.

For your convenience

If looking through the Emerson Liebert XDF user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson Liebert XDF on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson Liebert XDF to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson Liebert XDF User manual - Online PDF
Advertisement
« Page 1 of 60 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson Liebert XDF but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson Liebert XDF. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Precision Cooling
For Business-Critical Continuity

Liebert XDF
User Manual - 14kW Nominal Capacity, 60 Hz
?
ESC

Summary of the content on the page No. 2

Summary of the content on the page No. 3

TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 1.0 GLOSSARY OF SYMBOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 2.0 PRODUCT DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 2.1 Operational Overview—Self-Contained, Air Cooled Model . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 4

4.11 Side Panels—Remove and Replace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 4.11.1 Remove the Left Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 4.11.2 Remove the Right Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 4.11.3 Replace a Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 5

10.10 Uninterruptible Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 11.0 MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 11.1 Periodic Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 12.0 SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 6

TABLES Table 1 Optional condensate pump performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Table 2 Water supply flow rates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Table 3 Ethylene glycol concentrations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Table 4 Glycol supply flow rates . . . . . . . . . . . .

Summary of the content on the page No. 7

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions that must be closely followed during installation and maintenance of this unit to maintain compliance with agency listings. Read all safety and operating instructions before attempting to operate the XDF. Adhere to all warnings on the unit and in this manual. Follow all operating and user instructions. This product is designed for commercial / industrial use only. This product is not intended for

Summary of the content on the page No. 8

Glossary of Symbols 1.0 GLOSSARY OF SYMBOLS Hazardous Voltage Present Note following instructions Consult user manual for additional information Indicates weight Indicates ground connection Indicates alternating current 2

Summary of the content on the page No. 9

Product Description 2.0 PRODUCT DESCRIPTION Congratulations on purchasing a Liebert XDF. The XDF is an integrated equipment cabinet with built-in cooling and intelligent control to protect mission-critical enterprise systems from extreme heat. The XDF provides an organized, secure, controlled environment for your sensitive electronic equipment. The unit is available in a variety of configurations to suit your electronic equipment’s environmental requirements. The self-contained, air cooled L

Summary of the content on the page No. 10

Product Description 2.2 Operational Overview - Water/Glycol Cooled Model The water/glycol cooled XDF model employs a single-stage cooling system rated at 14kW to supply cooling air to the rack-mounted equipment. A bank of fans circulates this cooling air through the elec- tronic equipment in the XDF (see Figure 1). An evaporator coil extracts heat from the circulating air. That heat is transferred to a brazed plate condenser at the top of the XDF, transferred to the cooling water or glycol sol

Summary of the content on the page No. 11

Product Description Figure 3 Component location, rear of XDF Condenser fan SELF-CONTAINED (removable to reduce AIRCOOLEDMODEL height temporarily) Condenser air intakes, perforated grilles Door handle Backup ventilation damper (air exit) Rear door Service access for gauges to be inserted Condensate drain for testing Three-phase electrical cord, 10 feet (3m) Single-phase electrical cord, 10 feet (3m) Stabilizing foot Casters (one of four) WATER/GLYCOL COOLED MODEL Return Line (1" female, N

Summary of the content on the page No. 12

Product Description Figure 4 Dimensional data, self-contained, air cooled model 34-1/8" (867mm) Rack Section 24-1/8" 2-1/2" (613mm) (64mm) 82-1/4" (2089mm) 36U Control 79-3/4" Side (2026mm) 24-3/8" to 32-11/32 (620-821mm) mounting depth LEFT SIDE 49-1/2” (1257mm) FRONT 2-5/8" Cooling Section (68mm) 9-5/16" (252mm) Single-Phase Power Cord Entrance; factory-supplied, 10' (3m) NEMA 5-15P 3-Phase Power Cord Entrance; factory-supplied, 10' (3m) NEMA L21-30P Capped Service Gauge Access 45-3/4”

Summary of the content on the page No. 13

Product Description Figure 5 Dimensional data, water/glycol cooled model Cooling Section 5-1/2” Rack Section 9-5/16" (252mm) 6.95” (139.7mm) 24-1/8" (176.5mm) (613mm) 1.88” (47.6mm) 7” (177mm) Control Side 79-3/4" (2026mm) 45-3/4” (1162mm) Backup Ventilation Air Outlet 2-5/8" (68mm) 4-1/2” FRONT (114mm) Detail Area “A” REAR VIEW Single-Phase Power Cord Entrance; factory-supplied, 10' (3m) NEMA 5-15P 3-Phase Power Cord Entrance; factory-supplied, 10' (3m) NEMA L21-30P Capped Service 42U G

Summary of the content on the page No. 14

Product Description Figure 6 Dimensional data, all models—top, bottom and cable entry cutouts BOTTOM VIEW 4-1/2" TOP VIEW (114mm) Front A 4-3/8" (112mm) Cable Entry Cutouts 15" (381mm) B 4" (102mm) Cable Entry Cutout 4-1/2" Stabilizing Foot, Caster, 1 of 4 (114mm) Front 1 of 4 A - Rack-Mount Width EIA Nominal: 19" (483mm) Self-contained, air cooled model shown; water cooled unit Inside Dimension: 17-13/16 (452) dimensions are identical; water cooled unit does not have B - Adjustable Moun

Summary of the content on the page No. 15

XDF Components 3.0 XDF COMPONENTS 3.1 Standard Components—Self-Contained, Air Cooled and Water/Glycol Cooled Models 3.1.1 Frame The self-contained, air cooled XDF is 82-1/4 inches (2089mm) tall; the water/glycol cooled unit, 79-3/4 (2026) tall. The self-contained, air cooled XDF has 36U (63 inches) of usable rack height. The water/glycol cooled XDF has 42U (73-1/2 inches) of usable rack height. Both the self-contained, air cooled and water/glycol cooled XDF units have a standard EIA rack wid

Summary of the content on the page No. 16

XDF Components 3.1.5 Environmental Control The XDF supplies cooling air—68°F to 77°F (20-25°C)—to electronic equipment in the rack-mount equipment compartment. In normal operation, six fans at the right front corner of the XDF circulate cooling air through the equipment compartment. The laterally circulating air absorbs heat generated by the electronic equip- ment and transfers the heat to an evaporator coil at the right rear of the XDF. The heat is removed differently in the self-contained,

Summary of the content on the page No. 17

XDF Components Figure 8 Cooling system components—water cooled models Coolant Return Connection Brazed Plate Condenser Coolant Supply Connection Backup Ventilation Intake Vent (exhaust vent is on rear) Evaporator Coil (behind damper) extracts heat from cir- culated air Front Rear 11

Summary of the content on the page No. 18

XDF Components 3.1.6 Control—Liebert’s iCOM Controller The XDF is equipped with Liebert’s iCOM controller for all programming functions on the XDF. The menu-driven, 128 x 64 dot matrix graphic display shows the status of the conditioned space, set- points, alarm status and settings, event histories and the time. Refer to 10.2 - iCOM Components and Functions and 10.3 - Navigating Through the iCOM Display for details or call 800-543-2778. Figure 9 XDF with iCOM controller ? ESC Liebert iCOM cont

Summary of the content on the page No. 19

XDF Components 3.2 Coolant Source—Water/Glycol Models The XDF water/glycol cooled models may be connected to either of two types of coolant sources: • a closed-loop water system (cooling tower) • a drycooler loop 3.2.1 Closed-Loop Water System A closed water supply system is required for efficiency and to protect the equipment from particles and other contaminants that might obstruct the system’s piping. CAUTION ! Risk of dirt and debris contamination. May cause condenser clogging. Do not insta

Summary of the content on the page No. 20

XDF Components 3.2.2 Drycooler Loop The water/glycol cooled XDF model requires an external supply of coolant, either water or glycol, to remove heat extracted from the XDF. Contact the factory for drycooler requirements when connecting multiple XDF units. For information on setting up a drycooler system, contact your local Liebert representative. Figure 11 Water/glycol cooled general arrangement with drycooler as coolant source Expansion Tank (install at highest point in system) Supply Line


Alternative user manuals
# User manual Category Download
1 Emerson Active Tracking User manual Surge Protector 3
2 Emerson Islatrol RM-115-10R User manual Surge Protector 1
3 Emerson Islatrol RM-115-10RM User manual Surge Protector 3
4 Emerson SL-22075 User manual Surge Protector 2
5 Emerson 510 User manual Surge Protector 5
6 Emerson 381333234 E User manual Surge Protector 1
7 Emerson Islatrol RM-120-10RM User manual Surge Protector 1
8 Emerson Interceptor II TVSS User manual Surge Protector 4
9 Emerson Islatrol RM-120-10R User manual Surge Protector 2
10 Emerson Islatrol RM-120-10RML User manual Surge Protector 1
11 Emerson Liebert LM Series User manual Surge Protector 5
12 Emerson Liebert LPGE Series User manual Surge Protector 2
13 Emerson Liebert Surge and Signal Protection User manual Surge Protector 1
14 Emerson Liebert Precision Cooling User manual Surge Protector 3