ETA Systems ETA-ECM30 user manual

User manual for the device ETA Systems ETA-ECM30

Device: ETA Systems ETA-ECM30
Category: Surge Protector
Manufacturer: ETA Systems
Size: 0.98 MB
Added : 11/23/2013
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for ETA Systems ETA-ECM30. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with ETA Systems ETA-ECM30.

For your convenience

If looking through the ETA Systems ETA-ECM30 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual ETA Systems ETA-ECM30 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual ETA Systems ETA-ECM30 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
ETA Systems ETA-ECM30 User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual ETA Systems ETA-ECM30 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to ETA Systems ETA-ECM30. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

ETA-ECM30
30A AC Power Module Spike Suppressor
ETA-ECM30
30A AC Power Module
Spike Suppressor
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800-321-6699 • Fax: 800-996-3821
– 1 – ETAsys.com
Specifications are subject to change without notice.

Summary of the content on the page No. 2

ETA-ECM30 30A AC Power Module Spike Suppressor TABLE OF CONTENTS Important Safety Instructions .................................................................................................................. 3 Introduction ........................................................................................................................................... 5 Key Features ...................................................................................................................

Summary of the content on the page No. 3

ETA-ECM30 30A AC Power Module Spike Suppressor IMPORTANT SAFETY INSTRUCTIONS The lightning flash with arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage “ within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servici

Summary of the content on the page No. 4

ETA-ECM30 30A AC Power Module Spike Suppressor WARNING – WHEN THE DEVICE IS IN USE • T o prevent electric shock, do not remove the product cover as there are high voltage components inside. Refer all servicing to ETA Systems. • Should any of the following irregularities occur during use, immediately switch off the power , disconnect the power cord from the AC outlet and contact ETA Systems. Do not to attempt to continue operation with the product as this may cause fire or electri

Summary of the content on the page No. 5

ETA-ECM30 30A AC Power Module Spike Suppressor INTRODUCTION Thank you for purchasing the ETA Systems ETA-ECM30 AC Power Module Spike Suppressor Unit. Note: For your safety, all electrical wiring should be done by a qualified electrician. The ETA Systems ETA-ECM30 is an Electrical Control Module (ECM) 30A AC Spike Suppressor that is designed to be used as a stand-alone unit or in conjunction with an ETA-ECS6RM Controller up to 1000ft away. AC Spikes, or transients, are commonly caused by ut

Summary of the content on the page No. 6

ETA-ECM30 30A AC Power Module Spike Suppressor FRONT PANEL FEATURES 3 4 5 A B C D E 1 2 6 1. Trigger/Status Port Pin Identification All signals are of low voltage and current. DO NOT MISS WIRE or damage may occur. A. (+) requires a minimum of 5–24V DC to activate the module with 5mA of current. Note: The DCV can be supplied from any source. The EVS protection requires the ETA-ECS6RM for operation. B. G = Circuit Ground. Must be of the same circuit as the DCV source.

Summary of the content on the page No. 7

ETA-ECM30 30A AC Power Module Spike Suppressor ECM HOUSING TYPES ECM-RACEWY1 ECM-RACEWY3 ECM-RACEWY1 ECM-RACEWY3 ECM-RACEWY6 The ETA-ECM30 requires an electrical housing. These housings are manufactured by Atlas Sound and are available through ETA Systems. The ECM-RACEWY1 holds 1 ECM module, the ECM-RACEWY3 holds up to three ECM modules, and the ECM-RACEWY6 holds up to six ECM modules. Three standard ¾" and 1" electrical knockouts on the bottom of each raceway and a distribution area with c

Summary of the content on the page No. 8

ETA-ECM30 30A AC Power Module Spike Suppressor ECM MODULE ACTIVATION WITHOUT USING AN ETA-ECS6RM CONTROLLER Any of the ECM Modules can be triggered remotely to activate without using an ECS type Controller. If you do not need the features of the ECS controllers, remote activation can be accomplished by applying DC external voltage or by hard switch contacts. Note: The EVS and Voltage monitoring will be disabled when not using an ECS controller. Remote DC Voltage Trigger (+) requires a minimum

Summary of the content on the page No. 9

ETA-ECM30 30A AC Power Module Spike Suppressor WIRING THE ETA-ECM30 CONTROL MODULE The ETA-ECM30 is designed to be inserted in the ECM-RACEWY1, ECM-RACEWY3, or ECM-RACEWY6 housing. The specific job (install) AC power requirements and power distribution layout will dictate how the ECM modules are wired into the housing. The ETA-ECM30 Module can be wired as a single 30A run or in a parallel (loop thru) configuration. Each ECM module has dual 3-position screw terminal blocks that are in parall

Summary of the content on the page No. 10

ETA-ECM30 30A AC Power Module Spike Suppressor ETA-ECM30 SPECIFICATIONS Type AC Power Module Spike Suppressor RoHS Compliant Yes Safety Listings ETL (UL 60065 Standard) Front Panel Outlet Single 30A, L5-30 Indicators Active (Green), Fault (Red), Incoming AC (Red) External Trigger/Manual On Slide Switch Connectors 5 Position Phoenix Euro Block Style Hard Switch Remote Trigger SPST Contact Status Signals Output for Voltage (When used with ECM-6RM) AC Mains Interconnect Scre

Summary of the content on the page No. 11

ETA-ECM30 30A AC Power Module Spike Suppressor NOTES: 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800-321-6699 • Fax: 800-996-3821 – 11 – ETAsys.com Specifications are subject to change without notice.

Summary of the content on the page No. 12

ETA-ECM30 30A AC Power Module Spike Suppressor LIMITED WARRANTY All products manufactured by ETA Systems are warranted to the original dealer/installer, industrial or commercial purchaser to be free from defects in material and workmanship and to be in compliance with our published specifications, if any. This warranty shall extend from the date of purchase for a period of one year. Additionally, fuses and lamps carry no warranty. ETA Systems will solely at its discretion, replace at no char


Alternative user manuals
# User manual Category Download
1 ETA Systems ETA-ECM30 User manual Universal Remote 0
2 ETA Systems eta-ecm2063 User manual Surge Protector 0
3 ETA Systems ETA-S20 User manual Surge Protector 0
4 ETA Systems ETA-PD8 User manual Surge Protector 1
5 ETA Systems PS220 User manual Surge Protector 0
6 ETA Systems ETA-ECS3 User manual Surge Protector 2
7 Edelbrock 2101 User manual Surge Protector 1
8 Adcom ACE-615 User manual Surge Protector 0
9 Acoustic Research PW100 User manual Surge Protector 0
10 Alesis 7-51-0265-A User manual Surge Protector 2
11 Amtrol SPT-18 User manual Surge Protector 26
12 Amtrol SPT-56 User manual Surge Protector 0
13 Amtrol SPT-28 User manual Surge Protector 1
14 American Power Conversion E15 User manual Surge Protector 4
15 Acoustic Research PW101 User manual Surge Protector 1