Cooper Bussmann BRICK 6125TD user manual

User manual for the device Cooper Bussmann BRICK 6125TD

Device: Cooper Bussmann BRICK 6125TD
Category: Surge Protector
Manufacturer: Cooper Bussmann
Size: 0.89 MB
Added : 7/29/2013
Number of pages: 32
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Cooper Bussmann BRICK 6125TD. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Cooper Bussmann BRICK 6125TD.

For your convenience

If looking through the Cooper Bussmann BRICK 6125TD user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Cooper Bussmann BRICK 6125TD on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Cooper Bussmann BRICK 6125TD to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Cooper Bussmann BRICK 6125TD User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Cooper Bussmann BRICK 6125TD but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Cooper Bussmann BRICK 6125TD. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


Brick Fuses
6125TD Series, Time Delay
Description
• Time Delay surface mount fuse capable of replacing
glass tube fuses in certain applications
• Environmentally rugged, complies with EIA-IS-722
Standard
• Solder Immersion Compatible
• Targeted for Consumer Electronics
ELECTRICAL CHARACTERISTICS
% of Amp Rating Opening Time
100% 4 Hours Minimum
mm
200% 1 Second Minimum Dimensions ⁄(inches)
200% 2-4 Seconds Typical
200% 60 Seconds Maximum
Agency Information
• UL Recognition Guide & File numbers

Summary of the content on the page No. 2

™ Brick Fuses 6125TD Series, Time Delay TIME CURRENT CURVE 250mA and 375mA to be determined PACKAGING CODE Packaging Code Description SP2 50 piece sample TR1 Standard Package: (This is an insert) 1000 pieces of fuses on 12mm tape-and-reel on a 7 inch (177mm) reel per EIA Standard 481 OC-2530 Rev. M 5/03 Visit us on the Web at www.cooperET.com 3601 Quantum Boulevard Boynton Beach, Florida 33426-8638 © Cooper Electronic Technologies 2003 Tel: +1-561-752-5000 Toll Free: +1-888-414-2645 Fax

Summary of the content on the page No. 3

™ TCP Series Telecom Circuit Protector Description • The first and most reliable surface mount telecom circuit protector designed to protect against power cross faults and comply with all surge requirements. • Allows compliance with telecom regulatory standards including Bellcore GR 1089, UL 1950/60950, and FCC part 68. Application circuit testing is recommended. • Eliminates the need for a current limiting resistor. • Protects against overcurrent conditions found in telecom tip and ring applica

Summary of the content on the page No. 4

™ TCP Series Telecom Circuit Protector TIME CURRENT CURVE OPTIONS Option Code (Suffix) Description -R RoHS Compliant Version (Sn plating w/ Ni barrier) PACKAGING CODE Packaging Code Description TR2 2500 pieces of fuses on 24mm tape-and-reel on 13 inch (330mm) reel per EIA Standard 481, 8mm pitch Visit us on the web at: North America Europe Asia Pacific www.CooperET.com Cooper Electronic Technologies Cooper Bussmann Cooper Electronic Technologies Cooper Electronic Technologies 3601 Quantum Boulev

Summary of the content on the page No. 5

™ Brick Fuses 1025T Series Time Lag, Low Breaking Capacity Description • Designed to IEC 127-4 • Surface Mount fuse, time lag • Solder Immersion Compatible • Overcurrent protection of systems up to 250VAC ELECTRICAL CHARACTERISTICS % of Amp Rating Opening Time 125% 1 Hours Minimum 200% 2 Minutes Maximum 200% 1 Second Minimum mm 1000% 0.01 -- 0.1 Seconds Dimensions ⁄(inches) Drawing Not to Scale Approvals 1.4 ± 0.25 3.07 ± 0.15 1.4 ± 0.25 (0.055 ± 0.010) (0.121 ± 0.006) (0.055 ± 0.010) • Designed

Summary of the content on the page No. 6

™ Brick Fuses 1025T Series Time Lag, Low Breaking Capacity TIME CURRENT CURVE PACKAGING CODE Packaging Code Description TR2 2,500 pieces of fuses on 24mm tape-and-reel on 13 inch (330mm) reel per EIA Standard 481 TR3 50 pieces of fuses on 24mm tape packaged in a plastic box per EIA Standard 481 OC-2536 Rev. XF 5/03 Visit us on the Web at www.cooperET.com 3601 Quantum Boulevard Boynton Beach, Florida 33426-8638 © Cooper Electronic Technologies 2003 Tel: +1-561-752-5000 Toll Free: +1-888-41

Summary of the content on the page No. 7

™ Brick Fuses 1025F Series Fast Acting, Low Breaking Capacity Description • Surface mount fuse, fast acting • Designed to IEC 127-4 • Surface Mount • Solder Immersion Compatible • Overcurrent protection of systems up to 250 VAC ELECTRICAL CHARACTERISTICS % of Amp Rating Opening Time 125% 1 Hour Minimum 200% 2 Minutes Maximum mm Dimensions ⁄(inches) 1000% 0.001 - 0.01 Seconds Drawing Not to Scale 1.4 ± 0.25 1.4 ± 0.25 Approvals (0.055 ± 0.010) 3.07 ± 0.15 (0.055 ± 0.010) (0.121 ± 0.006) • Designe

Summary of the content on the page No. 8

™ Brick Fuses 1025F Series Fast Acting, Low Breaking Capacity TIME CURRENT CURVE 4000 4000 3000 3000 2000 2000 1000 1000 800 800 600 600 500 500 400 400 300 300 200 200 100 100 80 80 60 60 50 50 40 40 30 30 20 20 10 10 8 8 6 6 5 5 4 4 3 3 2 2 1 1 .8 .8 .6 .6 .5 .5 .4 .4 .3 .3 .2 .2 .1 .1 .08 .08 .06 .06 .05 .05 .04 .04 .03 .03 .02 .02 .01 .1 .01 .008 .008 .006 .006 .005 .005 .004 .004 .003 .003 .002 .002 .001 .001 CURRENT IN PERCENT PACKAGING CODE Packaging Code Description TR2 2500 pieces of

Summary of the content on the page No. 9

™ Brick Fuses 6125FA Series, Fast Acting Description • Surface Mount • Environmentally rugged, complies with the EIA-IS-722 Standard • Solder Immersion Compatible • Targeted for Consumer Electronics • Overcurrent protection of systems up to 125VAC/DC • Wire-in-air design ELECTRICAL CHARACTERISTICS % of Amp Rating Opening Time mm Dimensions ⁄(inches) 1.35+.25 1.35+.25 100% 4 Hours Minimum (0.053+.010) (0.053+.010) Drawing Not to Scale 200% 5 Seconds Maximum 2.59+.250 2.59+.25 Top View Agency Info

Summary of the content on the page No. 10

™ Brick Fuses 6125FA Series, Fast Acting TIME CURRENT CURVE PACKAGING CODE Packaging Code Description SP2 50 piece sample TR2 5000 pieces of fuses on 12mm tape-and-reel on a 13 inch (330mm) reel per EIA Standard 481 OC-2531 Rev. I 5/03 Visit us on the Web at www.cooperET.com 3601 Quantum Boulevard Boynton Beach, Florida 33426-8638 © Cooper Electronic Technologies 2003 Tel: +1-561-752-5000 Toll Free: +1-888-414-2645 Fax: +1-561-742-1178 This bulletin is intended to present product design

Summary of the content on the page No. 11

™ Brick Fuses 1025FA Series, Fast Acting Description • Surface Mount • Environmentally rugged, satisfies the EIA/IS-722 Standard • Solder Immersion Compatible • Targeted for Consumer Electronics ELECTRICAL CHARACTERISTICS % of Amp Rating Opening Time 100% 4 Hours Minimum 200% (250mA-5A) 5 Seconds Maximum 250% (250mA-5A fuse) 1 Second Maximum mm Dimensions ⁄(inches) 200% (7A-15A fuse) 20 Seconds Maximum Drawing Not to Scale 250% (7A-15A fuse) 4 Seconds Maximum Note: 30vde constant current source

Summary of the content on the page No. 12

™ Brick Fuses 1025FA Series, Fast Acting TIME CURRENT CURVE PACKAGING CODE Packaging Code Description SP1 50 piece sample TR2 2,500 pieces of fuses on 24mm tape-and-reel on 13 inch (330mm) reel per EIA Standard 481 OC-2538 Rev. X6 5/03 Visit us on the Web at www.cooperET.com 3601 Quantum Boulevard Boynton Beach, Florida 33426-8638 © Cooper Electronic Technologies 2003 Tel: +1-561-752-5000 Toll Free: +1-888-414-2645 Fax: +1-561-742-1178 This bulletin is intended to present product design

Summary of the content on the page No. 13

™ Brick Fuses 1025TD Series,Time Delay Description • Surface Mount • Environmentally rugged, satisfies the EIA/IS-722 Standard • Solder Immersion Compatible • Targeted for Consumer Electronics ELECTRICAL CHARACTERISTICS % of Amp Rating Opening Time 100% 4 Hours Minimum 200% 1 Second Minimum mm 200% 60 Seconds Maximum Dimensions ⁄(inches) 250% * 10 Seconds Maximum Drawing Not to Scale * If fuse does not open @ 200% in 60 seconds, raise current to 250% and the fuse must open in 10 seconds maximum.

Summary of the content on the page No. 14

™ Brick Fuses 1025TD Series,Time Delay TIME CURRENT CURVE PACKAGING CODE Packaging Code Description SP1 50 piece sample TR2 2,500 pieces of fuses on 24mm tape-and-reel on 13 inch (330mm) reel per EIA Standard 481 OC-2537 Rev. XH 5/03 Visit us on the Web at www.cooperET.com 3601 Quantum Boulevard Boynton Beach, Florida 33426-8638 © Cooper Electronic Technologies 2003 Tel: +1-561-752-5000 Toll Free: +1-888-414-2645 Fax: +1-561-742-1178 This bulletin is intended to present product design s

Summary of the content on the page No. 15

Engineering Product Specification TM TCP Telecom Circuit Protector - The information contained in this document is the property of Cooper Industries, Inc. It is not for public disclosure. Possession of the information does not convey any right to loan, sell or disclose the CONFIDENTIAL information. Unauthorized reproduction or use of the information is prohibited. This document is to be returned to Cooper Industries, Inc. Upon completion of th

Summary of the content on the page No. 16

Title: Engineering Product Specification Telecom Circuit Protector Revision: L Printed on: 7/14/2003 Sheet 2 of 18 Table of Contents Section Title Page 1. Scope 3 2. Manufacturer and Production Facility 3 3. Catalog Symbol and Part Numbering System 3 4. Mechanical Specifications 4 5. Electrical Specifications 6 6. Standards and Agency information 11 7. Marking Specification 13 8. Soldering Method 13 9. Land Pattern 14 10. Temperature Derating Curve 14 11. Packaging Speci

Summary of the content on the page No. 17

Title: Engineering Product Specification Telecom Circuit Protector Revision: L Printed on: 7/14/2003 Sheet 3 of 18 1.SCOPE 1.1 This Specification applies to Bussmann TCP series protectors. 2. MANUFACTURER AND PRODUCTION FACILITY 2.1 Manufacturer Cooper Electronic Technologies 3601 Quantum Boulevard Boynton Beach, FL 33426 Phone: (561) 752-5000 Fax: (561) 742-0134 2.2 Production Facility 1) Bussmann 2) NO. 59-12, 9 Lin 114 Old State

Summary of the content on the page No. 18

Title: Engineering Product Specification Telecom Circuit Protector Revision: L Printed on: 7/14/2003 Sheet 4 of 18 3.2.2 Ampere Rating Catalog Description Symbol TCP500mA 500mA Fuse TCP1.25A 1.25A Fuse TCP2A 2A Fuse 4. MECHANICAL SPECIFICATIONS 4.1 Construction (drawing not to scale) 1 2 3 4 5 6

Summary of the content on the page No. 19

Title: Engineering Product Specification Telecom Circuit Protector Revision: L Printed on: 7/14/2003 Sheet 5 of 18 4.2 Dimensions (drawings not to scale) 4.2.1 End View mm (inches) 2.77± 0.15 (0.109± 0.006) 2.77± 0.15 (0.109± 0.006) 4.2.2 Top View mm (inches) 1.40± 0.25 1.40± 0.25 (0.055± 0.010) (0.055± 0.010) 2.77± 0.15 (0.109± 0.006) 10.29± 0.20 (0.405± 0.008) 4.2.3 Side View

Summary of the content on the page No. 20

Title: Engineering Product Specification Telecom Circuit Protector Revision: L Printed on: 7/14/2003 Sheet 6 of 18 4.2.4 Orthogonal View 5. ELECTRICAL SPECIFICATIONS 5.1 Voltage Rating Voltage Rating Catalog Symbol AC TCP500mA 250 V TCP1.25A 250 V TCP2A 250 V 5.2 Interrupting Rating 5.2.1 AC Interrupting Rating (Measured at designated voltage, 100% power factor) Catalog Symbol Interrupting Rating AC 250 V 600 V* TCP500mA 50 A 40A TCP1.


Alternative user manuals
# User manual Category Download
1 Edelbrock 2101 User manual Surge Protector 1
2 Adcom ACE-615 User manual Surge Protector 0
3 Acoustic Research PW100 User manual Surge Protector 0
4 Alesis 7-51-0265-A User manual Surge Protector 2
5 Amtrol SPT-18 User manual Surge Protector 26
6 Amtrol SPT-56 User manual Surge Protector 0
7 Amtrol SPT-28 User manual Surge Protector 1
8 American Power Conversion E15 User manual Surge Protector 4
9 Acoustic Research PW101 User manual Surge Protector 1
10 Acoustic Research Six Outlet Home Office Surge Ecoefficie ARO6 User manual Surge Protector 2
11 Amtrol SPT-42 User manual Surge Protector 0
12 American Power Conversion E25 User manual Surge Protector 2
13 Amtrol SPT-21 User manual Surge Protector 0
14 Amtrol SPT-7 User manual Surge Protector 0
15 Amtrol SPT-35 User manual Surge Protector 0