Summary of the content on the page No. 1
INSTRUCTIONS–PARTS LIST 308846
Rev. D
This manual contains important
warnings and information.
First choice when
READ AND KEEP FOR REFERENCE.
quality counts.
INSTRUCTIONS
ACETAL HUSKY 307, STAND MOUNT
PRO/ Delta Spray Packages
Metal fluid fittings and hose couplings are stainless steel.
100 psi (0.7 MPa, 7 bar) Maximum Fluid Working Pressure
100 psi (0.7 MPa, 7 bar) Maximum Air Inlet Pressure
Packages with Fluid Pressure Regulators
Model No. 240367
with hoses and Delta Spray air spray gun
Mo
Summary of the content on the page No. 2
Instruction Manual – Parts List Changes This page contains a summary of changes or additions that do not appear in the contents of the manual. 308846 1A
Summary of the content on the page No. 3
Notes 308846 1B
Summary of the content on the page No. 4
Table of Contents Symbols Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Warning Symbol Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 WARNING WARNING Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Parts List and Parts Drawing This symbol alerts you to the possibility of serious 240367 to 240371 . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 5
WARNING EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and result INSTRUCTIONS in a serious injury. This equipment is for professional use only. Read all the instruction manuals, tags, and labels before operating the equipment. Use the equipment only for its intended purpose. If you are uncertain about usage, call your Graco distributor. Do not alter or modify this equipment. Use only genuine Graco parts and accessories.
Summary of the content on the page No. 6
Setup Preparing the Operator CAUTION Anybody who operates this system should be trained This equipment is compatible with most water-based in the safe, efficient operation of all system materials. See the wetted parts in the Technical components. At a minimum, all operators should Data section and your fluid and solvent thoroughly read the safety, setup, and operation manufacturer’s compatibility information. sections of this manual. Do not use acid catalyzed materials; they are incom- Preparin
Summary of the content on the page No. 7
Setup Hose Connections Grounding This package is shipped with the hoses connected. Before you disconnect any hoses, make a note of the WARNING proper connections. To reduce the risk of static sparking, the entire system must be grounded. Check your local electrical code for detailed grounding instructions Flush Pump Before First Use for your area and type of equipment. Ground all of The pump was tested in water. If the test solution this equipment. Also read FIRE AND EXPLOSION could contaminate
Summary of the content on the page No. 8
Operation 3. Slowly open the gun air regulator (F), and pull the Using the Gun gun trigger just enough to open only the air valve See the gun instruction manual for gun operation, in the gun. With the gun air triggered, set the gun care, flushing, cleaning, and technical data. Read the air pressure to 60 psi (413 kPa, 4 bar). entire gun manual before operating the sprayer. NOTE: Gun air pressure higher than 60 psi (413 Pressure Relief Procedure kPa, 4 bar) will cause excessive overspray and l
Summary of the content on the page No. 9
Operation Priming the System See Fig. 1 1. Close the gun air regulator (F). 6. Slowly open the gun air regulator (F), and pull the gun trigger just enough to open only the air valve 2. If your system has a fluid pressure regulator (G), in the gun. With the gun air triggered, set the gun close it. air pressure to 60 psi (413 kPa, 4 bar). 7. Hold the gun against and aimed into a grounded 3. Open the recirculating valve (J). metal waste pail, and fully trigger the gun. If your system has a flui
Summary of the content on the page No. 10
Operation 3. Place the suction tube into a grounded metal pail Using the Recirculation Feature of compatible solvent. See Fig. 1 4. Make sure the air regulators (E and F) and The recirculation tube drains unused fluid back into the bleed-type master air valve (K) are closed. Open fluid container, ensuring an even flow at the gun. the recirculating valve (J). Recirculation also provides gentle fluid agitation. To recirculate fluid, open the recirculation valve (J) while NOTE: The gun air regulat
Summary of the content on the page No. 11
Maintenance See the separate component instruction manuals for individual component maintenance procedures. Access to some system components requires that you remove the shields. The following steps are for shield removal. Shield replacement is the reverse of these steps, so make sure you take notes on the proper hose connections. Depending on your system, see the Parts Drawings on pages 11 and 13 for number call-outs. You cannot remove the front shield assembly while the pump and shields are
Summary of the content on the page No. 12
Parts List Stand-Mount Packages with Fluid Pressure Regulators Model No. 240367, Delta Spray air spray package Model No. 240368, Delta Spray HVLP package Model No. 240369, PRO 3500sc electrostatic package Model No. 240370, PRO 4500sc electrostatic package Model No. 240371, no hoses or gun Ref. Ref. No. Part No. Description Qty. No. Part No. Description Qty. 1 240210 SHIELD ASSY, front 38 239542 GUN, Delta Spray, air spray Contains 1a to 1h, shown in Fig. 2 on Model 240367 page 9 1 See instructio
Summary of the content on the page No. 13
Parts Drawing Stand-Mount Packages with Fluid Pressure Regulators Model No. 240367, Delta Spray air spray package Model No. 240368, Delta Spray HVLP package Model No. 240369, PRO 3500sc electrostatic package Model No. 240370, PRO 4500sc electrostatic package Model No. 240371, no hoses or gun Grounding Detail 26 29 32 27 37 18 40 13 10 31 30 28 19 25 17 12 1 24 18 9 34 16 6 17 4 16 5 4 33 44 7 45 24 8 32 49 Note: For PRO packages only, terminal end of ground wire (49) is assembled 47 21 22, betw
Summary of the content on the page No. 14
Parts List Stand-Mount Packages with Surge Tanks Model No. 240379, Delta Spray air spray package Model No. 240380, Delta Spray HVLP package Model No. 240381, no hoses or gun Ref. Ref. No. Part No. Description Qty. No. Part No. Description Qty. 1 240210 SHIELD ASSY, front 27 114456 FITTING, elbow, male 2 Contains 1a to 1h, shown in Fig. 2 on 28 054175 TUBE, recirculation 32 in. page 9 1 29 192994 HANDLE, shield 1 3 054139 TUBE, suction 30 in. 30 111911 STRAINER, line 1 4 111917 NIPPLE; Nylon 2 31
Summary of the content on the page No. 15
Parts Drawing Stand-Mount Packages with Surge Tanks Model No. 240379, Delta Spray air spray package Model No. 240380, Delta Spray HVLP package Model No. 240381, no hoses or gun Grounding Detail 31 26 37 18 30 40 29 27 32 13 10 17 32 19 25 12 1 18 24 9 34 16 27 17 4 16 5 4 33 44 7 45 24 8 32 28 21 22, 23 22 41 23 3 44 38 42 43 39
Summary of the content on the page No. 16
Accessory Fluid Filter Kit Fluid Filter Kit 240440 Ref. No. Part No. Description Qty. To avoid sharp bends in the tube, you may have to cut it to a shorter length. 101 114361 FILTER, fluid 1 Apply Graco Thread Sealer, or Loctite 567, or equiv- 102 113322 CONNECTOR, male 1 alent to male threads. 103 054188 TUBE; PTFE;3/8” O.D. 8 in. For initial installation, make sure the dome is firmly 104 113534 ELBOW, male x female 2 hand tightened onto the filter body. Do not use a 105 111917 NIPPLE
Summary of the content on the page No. 17
Accessory Suction Tube Kit Suction Tube Kit 240465 Ref. Apply Graco Thread Sealer, or Loctite 567, or equiv- alent to threads. No. Part No. Description Qty. 201 232692 KIT ASSEMBLY, suction tube 1 202 193411 NIPPLE 1 203 193459 TUBE, recirculation 1 204 103473 TIE, wire 5 The Suction Kit, listed above, can be installed for drawing fluid from a container that is not directly under the unit. Install the Suction Kit as follows (see Fig. 4): 202 1. Remove the following parts from the stand unit
Summary of the content on the page No. 18
Technical Data Category Data Maximum fluid working pressure 100 psi (0.7 MPa, 7 bar) Maximum incoming air pressure 100 psi (0.7 MPa, 7 bar) Maximum operating temperature 120 F (49 C) Gun See separate gun instruction manual. Pump See separate pump instruction manual. Fluid pressure regulator See separate fluid pressure regulator instruction manual. Air pressure regulators See separate air pressure regulator instruction manual. Wetted parts: fluid hoses for Delta guns nylon, stainless steel Wet
Summary of the content on the page No. 19
Dimensions 34.0 in. (864 mm) 17.5 in. 16.5 in. (445 mm) (419 mm)
Summary of the content on the page No. 20
Notes