Graco Inc. Hydra-Spray 306706 user manual

User manual for the device Graco Inc. Hydra-Spray 306706

Device: Graco Inc. Hydra-Spray 306706
Category: Paint Sprayer
Manufacturer: Graco Inc.
Size: 0.32 MB
Added : 10/13/2013
Number of pages: 14
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Graco Inc. Hydra-Spray 306706. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Graco Inc. Hydra-Spray 306706.

For your convenience

If looking through the Graco Inc. Hydra-Spray 306706 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Graco Inc. Hydra-Spray 306706 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Graco Inc. Hydra-Spray 306706 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Graco Inc. Hydra-Spray 306706 User manual - Online PDF
Advertisement
« Page 1 of 14 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Graco Inc. Hydra-Spray 306706 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Graco Inc. Hydra-Spray 306706. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


Instructions–Parts List
STATIONARY AIRLESS PAINT SPRAYER
 
30:1 President Hydra–Spray 306706W
Used for airless spray application of paints and other coatings from
a 50–gallon drum.
3000 psi (21.0 MPa, 210 bar) Maximum Working Pressure
100 psi (0.7 MPa, 7 bar) Maximum Air Input Pressure
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
Model 231063, Series C
04277

Summary of the content on the page No. 2

Table of Contents Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Adjusting the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Installation Starting and Adjusting the Pump . . . . . . . . . . . . . . . 9 Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Shutdown and Care of the Pump . . . . . . . . . . . . . . 9 Positioning the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Parts Drawing . . . . . .

Summary of the content on the page No. 3

WARNING EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury. INSTRUCTIONS  This equipment is for professional use only.  Read all instruction manuals, tags, and labels before operating the equipment.  Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor.  Do not alter or modify this equipment. Use only Graco parts and accessories.  Check equipment daily. Repair or replace worn

Summary of the content on the page No. 4

WARNING SKIN INJECTION HAZARD Spray from the gun, leaks, or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury.  Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate surgical treatment.  Do not point the gun at anyone or at any part of the body.  Do not put your hand or fingers over the spray tip.  Do n

Summary of the content on the page No. 5

WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury.  Ground the equipment and the object being sprayed. Refer to Grounding on page 6.  If there is any static sparking or you feel an electric shock while using this equipment, stop spray- ing immediately. Do not use the equipment until you identify and correct the problem.  Provide fresh air ventilation to avoid the

Summary of the content on the page No. 6

Installation NOTES: Object being sprayed: Follow your local code.  Reference numbers and letters in parentheses in Fluid supply container: Follow your local code. the text refer to the callouts in the figures and the parts drawing. Solvent pails used when flushing: Follow your local code. Use only metal pails, which are conductive,  Accessories are available from your Graco repre- placed on a grounded surface. Do not place the pail sentative. If you supply your own accessories, be on a n

Summary of the content on the page No. 7

Installation The installation shown in Fig. 2 is only a guide for selecting and installing system components and accessories. Contact your Graco distributor for assistance in designing a system to suit your particular needs. To order an air line filter, order by Part No. from the Connecting the Unit and Accessories list below:  Ground the unit as described in Grounding on 203421 1/2” npt inlet and outlet, with gauge, page 6. 200 psi (1.4 MPa, 14 bar) maximum working pressure. See instruction ma

Summary of the content on the page No. 8

Operation/Maintenance pump parts. If the fluid you are using may be contami- Pressure Relief Procedure nated by the oil, flush it out with a compatible solvent. WARNING WARNING SKIN INJECTION HAZARD The system pressure must be manually To reduce the risk of serious injury whenever you relieved to prevent the system from are instructed to relieve pressure, always follow the starting or spraying accidentally. Fluid Pressure Relief Procedure at left. under high pressure can be injected through th

Summary of the content on the page No. 9

Operation/Maintenance 3. Push in on the air valve knob to lower the elevator, CAUTION so the cover (A) rests on the top lip of the drum. The support clamp (K) recesses must be tight Do not allow the pump to run dry. It will quickly against the elevator riser tube. The pump intake accelerate to a high speed, causing damage. If valve feet (B) must contact and support the perfo- your pump is running too fast, stop it immediately rated plate (9) as shown in Fig. 2. and check the fluid supply. If

Summary of the content on the page No. 10

Parts Drawing Model 231063, Series C, 30:1 President Hydra-Spray 20 35 2 4 23 28 31 104 7 32 3 9 40 8 19 49 47 46 75 70 45 39 A 76 1 21 51 74 42 31 44 48 25 30 43 52 24 26 43, 44 38 37 23 A 10 71 69 36 12 45 11 5 46 34 6a 29 6b 98 6c 15 A 6d 6e 06218 10 306706 06218A

Summary of the content on the page No. 11

Parts List Model 231063, Series C, 30:1 President Hydra-Spray Ref. Ref. No. Part No. Description Qty. No. Part No. Description Qty. 1 202295 VALVE, push-pull 29 101909 CONNECTOR, male; See 306287 for parts. 1 1/2–28 x 3/8” tube; 1/4 npt(m) 1 2 203743 VALVE, restrictor 30 158491 NIPPLE; 1/2” npt 1 See 306287 for parts. 1 31 TUBE; nylon; 1/4 in. (6.4mm) OD, 3 204385 ELEVATOR 250 psi (1.7 MPa, 17 bar) working See 306287 for parts. 1 pressure, 7 ft. (213 cm) 1 4 204940 SWIVEL See 306861 for par

Summary of the content on the page No. 12

Notes 12 306706

Summary of the content on the page No. 13

Technical Data Ratio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30:1 Maximum fluid working pressure . . . . . . . . . . . . . . . . . . . 3000 psi (21 MPa, 207 bar) Maximum air input pressure . . . . . . . . . . . . . . . . . . . . . . . . . . 100 psi (0.7 MPa, 7 bar) Recommended pump speed for continuous operation . . . . . . . . . 60 cycles per min Maximum flow . . . . . . . . . . . . . . . . . . . . . . . . 3.8

Summary of the content on the page No. 14

Graco Standard Warranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, oper


Alternative user manuals
# User manual Category Download
1 Graco Inc. 1095 Premium Hi-Boy User manual Paint Sprayer 11
2 Graco Inc. 12004 User manual Paint Sprayer 1
3 Graco Inc. 111418a User manual Paint Sprayer 1
4 Graco Inc. 12004X User manual Paint Sprayer 2
5 Graco Inc. 12006 User manual Paint Sprayer 2
6 Graco Inc. 12005 User manual Paint Sprayer 0
7 Graco Inc. 1095 Premium Hi User manual Paint Sprayer 1
8 Graco Inc. 1595 HI User manual Paint Sprayer 3
9 Graco Inc. 207-945 User manual Paint Sprayer 7
10 Graco Inc. 1595 Premium Hi User manual Paint Sprayer 2
11 Graco Inc. 208-748 User manual Paint Sprayer 0
12 Graco Inc. 208-749 User manual Paint Sprayer 1
13 Graco Inc. 1595 Premium Hi-Boy User manual Paint Sprayer 6
14 Graco Inc. 208-644 User manual Paint Sprayer 1
15 Graco Inc. 218-026 User manual Paint Sprayer 2
16 3M Series 52 User manual Paint Sprayer 1
17 3M Series 56 User manual Paint Sprayer 0
18 3M Series 56ZZ User manual Paint Sprayer 1
19 3M Series 55ZZ User manual Paint Sprayer 1
20 3M Series 57 User manual Paint Sprayer 1