Graco Inc. 240-351 user manual

User manual for the device Graco Inc. 240-351

Device: Graco Inc. 240-351
Category: Paint Sprayer
Manufacturer: Graco Inc.
Size: 1.02 MB
Added : 9/15/2014
Number of pages: 18
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Graco Inc. 240-351. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Graco Inc. 240-351.

For your convenience

If looking through the Graco Inc. 240-351 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Graco Inc. 240-351 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Graco Inc. 240-351 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Graco Inc. 240-351 User manual - Online PDF
Advertisement
« Page 1 of 18 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Graco Inc. 240-351 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Graco Inc. 240-351. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTRUCTIONS–PARTS LIST 308–845
Rev. C
This manual contains important
warnings and information.
First choice when
READ AND KEEP FOR REFERENCE.
quality counts.
INSTRUCTIONS
ACETAL HUSKY 307, WALL-MOUNT PUMP, DRUM SUCTION
PRO/ Delta Spray Packages
Metal fluid fittings and hose couplings are stainless steel.
100 psi (0.7 MPa, 7 bar) Maximum Fluid Working Pressure
100 psi (0.7 MPa, 7 bar) Maximum Air Inlet Pressure
Packages with Fluid Pressure Regulators
Model No. 240–349
with hoses and Delta Sp

Summary of the content on the page No. 2

Instruction Manual – Parts List Changes This page contains a summary of changes or additions that do not appear in the contents of the manual. 308845 1A

Summary of the content on the page No. 3

Notes 308845 1B

Summary of the content on the page No. 4

Table of Contents Symbols Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Warning Symbol Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 WARNING WARNING Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Parts List and Parts Drawing This symbol alerts you to the possibility of serious 240–349 to 240–353 . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 5

WARNING EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and result INSTRUCTIONS in a serious injury.  This equipment is for professional use only.  Read all the instruction manuals, tags, and labels before operating the equipment.  Use the equipment only for its intended purpose. If you are uncertain about usage, call your Graco distributor.  Do not alter or modify this equipment. Use only genuine Graco parts and accessories. 

Summary of the content on the page No. 6

Setup Preparing the Operator CAUTION Anybody who operates this system should be trained This equipment is compatible with most water-based in the safe, efficient operation of all system materials. See the wetted parts in the Technical components. At a minimum, all operators should Data section and your fluid and solvent thoroughly read the safety, setup, and operation manufacturer’s compatibility information. sections of this manual. Do not use acid catalyzed materials; they are incom- Preparin

Summary of the content on the page No. 7

Setup Assembling the Wall-Mount Unit Grounding See Fig. 1 Install the wall bracket (G) 5 ft (1.5 m) above the floor. WARNING For proper hole dimensions, use the Wall Mounting To reduce the risk of static sparking, the entire Hole Layout on page 15. Be sure the wall is strong system must be grounded. Check your local enough to support the weight of the pump and hoses, electrical code for detailed grounding instructions any accessories, the fluid, and stress caused by pump for your area and type

Summary of the content on the page No. 8

Operation 3. Slowly open the gun air regulator (F), and pull the Using the Gun gun trigger just enough to open only the air valve See the gun instruction manual for gun operation, in the gun. With the gun air triggered, set the gun care, flushing, cleaning, and technical data. Read the air pressure to 60 psi (413 kPa, 4 bar). entire gun manual before operating the sprayer. NOTE: Gun air pressure higher than 60 psi (413 Pressure Relief Procedure kPa, 4 bar) will cause excessive overspray and l

Summary of the content on the page No. 9

Operation Priming the System See Fig. 1 1. Close the gun air regulator (F). 5. Slowly open the gun air regulator (F), and pull the gun trigger just enough to open only the air valve 2. If your system has a fluid pressure regulator (G), in the gun. With the gun air triggered, set the gun close it. air pressure to 60 psi (413 kPa, 4 bar). 6. Hold the gun against and aimed into a grounded 3. Open the bleed-type master air valve (K). metal waste pail, and fully trigger the gun. If your system ha

Summary of the content on the page No. 10

Operation 4. Make sure the air regulators (E and F) are closed. When to Shut Down the System NOTE: The gun air regulator (F) always stays Shut down the system at the end of the work shift and closed during flushing. before checking, adjusting, cleaning, or repairing the system. Always relieve the pressure. 5. Open the bleed-type master air valve (K). 6. Slowly open the pump air regulator (E) until the WARNING pump starts. To reduce the risk of serious injury whenever you 7. Hold the gun against

Summary of the content on the page No. 11

Maintenance See the separate component instruction manuals for individual component maintenance procedures. Access to some system components requires that you remove the shields. The following steps are for shield removal. Shield replacement is the reverse of these steps, so make sure you take notes on the proper hose connections. Depending on your system, see the Parts Drawings on pages 11 and 13 for number call-outs. Front Shield Assembly (1) Back Shield (25) 1. Disconnect the pump air hose

Summary of the content on the page No. 12

Parts List Wall-Mount Packages with Fluid Pressure Regulators Model No. 240–349, Delta Spray air spray package Model No. 240–350, Delta Spray HVLP package Model No. 240–351, no hoses (31) or gun (30) Model No. 240–352, PRO 3500sc electrostatic package Model No. 240–353, PRO 4500sc electrostatic package Ref. Ref. No. Part No. Description Qty. No. Part No. Description Qty. 1 240–210 SHIELD ASSY, front 30 239–542 GUN, Delta Spray, air spray Contains 1a to 1h, shown in Fig. 2 on Model 240–349 p

Summary of the content on the page No. 13

Parts Drawing Grounding Detail Wall-Mount Packages with Fluid Pressure Regulators Model No. 240–349, Delta Spray air spray package 26 Model No. 240–350, Delta Spray HVLP package 37 Model No. 240–351, no hoses (31) or gun (30) Model No. 240–352, PRO 3500sc electrostatic package Model No. 240–353, PRO 4500sc electrostatic package 19 20 32 39 50 16 28 3 2 27 8 29 7 25 1 24 21 16 34 15 40 27 10 15 9 33 13 9 17 24 5 11 6 12 30 30 222–300 shown 38 31 31  

Summary of the content on the page No. 14

Parts List Wall-Mount Packages with Surge Tanks Model No. 240–361, Delta Spray air spray package Model No. 240–362, Delta Spray HVLP package Model No. 240–363, no hoses (31) or gun (30) Ref. Ref. No. Part No. Description Qty. No. Part No. Description Qty. 1 240–210 SHIELD ASSY, front 25 192–996 SHIELD, back 1 Contains 1a to 1h, shown in Fig. 2 on 26 104–029 LUG, grounding 1 page 9 1 27 054–139 TUBE; Nylon 11.5 in. 3 106–285 BOLT, “U” 2 29 189–220 LABEL, warning 1 5 104–123 WASHER, spring loc

Summary of the content on the page No. 15

Parts Drawing Grounding Detail Wall-Mount Packages with Surge Tanks Model No. 240–361, Delta Spray air spray package 26 Model No. 240–362, Delta Spray HVLP package 37 Model No. 240–363, no hoses (31) or gun (30) 19 20 3 7 50 32 16 40 27 29 8 25 16 1 24 21 34 15 40 27 10 15 9 33 13 9 17 24 5 11 6 12 30 38 31   

Summary of the content on the page No. 16

Accessory Fluid Filter Kit Fluid Filter Kit 240–440 Ref.  To avoid sharp bends in the tube, you may have to cut it to a shorter length. No. Part No. Description Qty.  Apply Graco Thread Sealer, or Loctite 567, or equiv- 101 114–361 FILTER, fluid 1 alent to male threads. 102 113–322 CONNECTOR, male 1  For initial installation, make sure the dome is firmly 103 054–188 TUBE; PTFE;3/8” O.D. 8 in. hand tightened onto the filter body. Do not use a 104 113–534 ELBOW, male x female 2 tool. Durin

Summary of the content on the page No. 17

Technical Data Category Data Maximum fluid working pressure 100 psi (0.7 MPa, 7 bar) Maximum incoming air pressure 100 psi (0.7 MPa, 7 bar) Maximum operating temperature 120 F (49 C) Gun See separate gun instruction manual. Pump See separate pump instruction manual. Fluid pressure regulator See separate fluid pressure regulator instruction manual. Air pressure regulators See separate air pressure regulator instruction manual. Wetted parts: fluid hoses for Delta guns nylon, stainless steel Wet

Summary of the content on the page No. 18

Graco Standard Warranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only wh


Alternative user manuals
# User manual Category Download
1 Graco Inc. 1095 Premium Hi-Boy User manual Paint Sprayer 11
2 Graco Inc. 12004 User manual Paint Sprayer 1
3 Graco Inc. 111418a User manual Paint Sprayer 1
4 Graco Inc. 12004X User manual Paint Sprayer 2
5 Graco Inc. 12006 User manual Paint Sprayer 2
6 Graco Inc. 12005 User manual Paint Sprayer 0
7 Graco Inc. 1095 Premium Hi User manual Paint Sprayer 1
8 Graco Inc. 1595 HI User manual Paint Sprayer 3
9 Graco Inc. 207-945 User manual Paint Sprayer 7
10 Graco Inc. 1595 Premium Hi User manual Paint Sprayer 2
11 Graco Inc. 208-748 User manual Paint Sprayer 0
12 Graco Inc. 208-749 User manual Paint Sprayer 1
13 Graco Inc. 1595 Premium Hi-Boy User manual Paint Sprayer 6
14 Graco Inc. 208-644 User manual Paint Sprayer 1
15 Graco Inc. 218-026 User manual Paint Sprayer 2
16 3M Series 52 User manual Paint Sprayer 1
17 3M Series 56 User manual Paint Sprayer 0
18 3M Series 56ZZ User manual Paint Sprayer 1
19 3M Series 55ZZ User manual Paint Sprayer 1
20 3M Series 57 User manual Paint Sprayer 1