Teledyne 3000PA user manual

User manual for the device Teledyne 3000PA

Device: Teledyne 3000PA
Category: Oxygen Equipment
Manufacturer: Teledyne
Size: 0.92 MB
Added : 8/27/2013
Number of pages: 69
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Teledyne 3000PA. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Teledyne 3000PA.

For your convenience

If looking through the Teledyne 3000PA user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Teledyne 3000PA on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Teledyne 3000PA to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Teledyne 3000PA User manual - Online PDF
Advertisement
« Page 1 of 69 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Teledyne 3000PA but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Teledyne 3000PA. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Percent Oxygen Analyzer
OPERATING INSTRUCTIONS FOR
Model 3000PA
Percent Oxygen Analyzer
DANGER
HIGHLY TOXIC AND OR FLAMMABLE LIQUIDS OR GASES MAY BE PRESENT IN THIS
MONITORING SYSTEM.
PERSONAL PROTECTIVE EQUIPMENT MAY BE REQUIRED WHEN SERVICING THIS SYSTEM.
HAZARDOUS VOLTAGES EXIST ON CERTAIN COMPONENTS INTERNALLY WHICH MAY PER-
P/N M64573
SIST FOR A TIME EVEN AFTER THE POWER IS TURNED OFF AND DISCONNECTED.
08/06/99
ONLY AUTHORIZED PERSONNEL SHOULD CONDUCT MAINTENANCE AND/OR SERVICING.
BEFORE C

Summary of the content on the page No. 2

Model 3000PA Copyright © 1999 Teledyne Analytical Instruments All Rights Reserved. No part of this manual may be reproduced, transmitted, tran- scribed, stored in a retrieval system, or translated into any other language or computer language in whole or in part, in any form or by any means, whether it be electronic, mechanical, magnetic, optical, manual, or otherwise, without the prior written consent of Teledyne Analytical Instruments, 16830 Chestnut Street, City of Industry, CA 91749-1580. Wa

Summary of the content on the page No. 3

Percent Oxygen Analyzer Specific Model Information The instrument for which this manual was supplied may incorporate one or more options not included with the standard instrument. Commonly available options are listed below, with check boxes. Any that are incorporated in the instrument for which this manual is supplied are indicated by a check mark in the box. Instrument Serial Number _______________________ includes the following options: !! !!! 3000PA-C: In addition to all standard features,

Summary of the content on the page No. 4

Model 3000PA Table of Contents 1 Introduction 1.1 Overview ........................................................................ 1-1 1.2 Typical Applications....................................................... 1-1 1.3 Main Features of the Analyzer ....................................... 1-1 1.4 Model Designations ....................................................... 1-2 1.5 Front Panel (Operator Interface) ..................................... 1-3 1.6 Recognizing Difference Between LCD &

Summary of the content on the page No. 5

Percent Oxygen Analyzer 4.3.3.2 Installing or Changing the Password ............. 4-7 4.3.4 Logout .................................................................... 4-8 4.3.5 System Self-Diagnostic Test .................................. 4-9 4.3.6 Version Screen ...................................................... 4-9 4.4 The Zero and Span Functions ....................................... 4-10 4.4.1 Cell Failure ............................................................ 4-12 4.4.2 Span C

Summary of the content on the page No. 6

Model 3000PA DANGER COMBUSTIBLE GAS USAGE WARNING This is a general purpose instrument designed for usage in a nonhazardous area. It is the customer's responsibility to ensure safety especially when combustible gases are being analyzed since the potential of gas leaks always exist. The customer should ensure that the principles of operating of this equipment is well understood by the user. Misuse of this product in any manner, tampering with its components, or unau- thorized substitution of an

Summary of the content on the page No. 7

Percent Oxygen Analyzer Introduction 1 Introduction 1.1 Overview The Teledyne Analytical Instruments Model 3000PA Percent Oxygen Analyzer is a versatile microprocessor- based instrument for detecting the percentage of oxygen in a variety of background gases. This manual covers the Model 3000PA General Purpose flush-panel and/or rack-mount units only. These units are for indoor use in a nonhazardous environment. 1.2 Typical Applications A few typical applications of the Model 3000PA are:  Moni

Summary of the content on the page No. 8

1 Introduction Model 3000PA  Advanced Micro-Fuel Cell, designed for percent oxygen analysis. Several options are available.  Versatile analysis over a wide range of applications.  Microprocessor based electronics: 8-bit CMOS microprocessor with 32 kB RAM and 128 kB ROM.  Three user definable output ranges (from 0-1% through 0-100 %) allow best match to users process and equipment.  Air-calibration range for convenient spanning at 20.9 %.  Auto Ranging allows analyzer to automatically s

Summary of the content on the page No. 9

Percent Oxygen Analyzer Introduction 1 All of the above options are available in combination. For example, the -C and -V options are combined as Model 3000PA-C-V. Figure 1-1: Model 3000PA Front Panel 1.5 Front Panel (Operator Interface) The standard 3000PA is housed in a rugged metal case with all controls and displays accessible from the front panel. See Figure 1-1. The front panel has thirteen buttons for operating the analyzer, a digital meter, an alphanu- meric display, and a window for

Summary of the content on the page No. 10

1 Introduction Model 3000PA Function Keys: Six touch-sensitive membrane switches are used to change the specific function performed by the analyzer:  Analyze Perform analysis for oxygen content of a sample gas.  System Perform system-related tasks (described in detail in chapter 4, Operation.).  Span Span calibrate the analyzer.  Zero Zero calibrate the analyzer.  Alarms Set the alarm setpoints and attributes.  Range Set up the 3 user definable ranges for the instrument. Data Entry Key

Summary of the content on the page No. 11

Percent Oxygen Analyzer Introduction 1 Access Door: To provide access to the Micro-Fuel Cell, the front panel swings open when the latch in the upper right corner of the panel is pressed all the way in with a narrow gauge tool. Accessing the main circuit board requires unfastening the rear panel screws and sliding the unit out of the case. 1.6 Recognizing Difference Between LCD & VFD LCD has GREEN background with BLACK characters. VFD has DARK background with GREEN characters. In th

Summary of the content on the page No. 12

1 Introduction Model 3000PA  Alarm Connections 2 concentration alarms and 1 system alarm.  RS-232 Port Serial digital concentration signal output and control input.  Remote Probe Used in the 3000PA for controlling external solenoid valves only.  Remote Span/Zero Digital inputs allow external control of analyzer calibration. (See Note, below.)  Calibration Contact To notify external equipment that instrument is being calibrated and readings are not monitoring sample.  Range ID Contacts

Summary of the content on the page No. 13

Percent Oxygen Analyzer Operational Theory 2 Operational Theory 2.1 Introduction The analyzer is composed of three subsystems: 1. Micro-Fuel Cell Sensor 2. Sample System 3. Electronic Signal Processing, Display and Control The sample system is designed to accept the sample gas and transport it through the analyzer without contaminating or altering the sample prior to analysis. The Micro-Fuel Cell is an electrochemical galvanic device that translates the amount of oxygen present in the sample in

Summary of the content on the page No. 14

2 Operational Theory Model 3000PA analyzed. The Micro-Fuel Cell is therefore a hybrid between a battery and a true fuel cell. (All of the reactants are stored externally in a true fuel cell.) 2.2.2 Anatomy of a Micro-Fuel Cell The Micro-Fuel Cell is a cylinder only 1¼ inches in diameter and 1 inch thick. It is made of extremely inert plastic, which can be placed confi- dently in practically any environment or sample stream. It is effectively sealed, although one end is permeable to oxygen i

Summary of the content on the page No. 15

Percent Oxygen Analyzer Operational Theory 2 2 the oxygen sensing element—the cathode—with a surface area almost 4 cm . The cathode has many perforations to ensure sufficient wetting of the upper surface with electrolyte, and it is plated with an inert metal. The anode structure is below the cathode. It is made of lead and has a proprietary design which is meant to maximize the amount of metal available for chemical reaction. At the rear of the cell, just below the anode structure, is a flexibl

Summary of the content on the page No. 16

2 Operational Theory Model 3000PA (These reactions will hold as long as no gaseous components capable of oxidizing lead—such as iodine, bromine, chlorine and fluorine—are present in the sample.) The output of the fuel cell is limited by (1) the amount of oxygen in the cell at the time and (2) the amount of stored anode material. In the absence of oxygen, no current is generated. 2.2.4 The Effect of Pressure In order to state the amount of oxygen present in the sample as a per- centage of t

Summary of the content on the page No. 17

Percent Oxygen Analyzer Operational Theory 2 Figure 2-3. Characteristic Input/Output Curve for a Micro-Fuel Cell 2.2.6 Micro-Fuel Cell “Class” TBE manufactures Micro-Fuel Cells with a variety of characteristics to give the best possible performance for any given sample conditions. A few typical Micro-Fuel Cells are listed below with their typical use and electrical specifications. 2.2.6.1 Class A-3 Cell The class A-3 cell is for use in applications where it is exposed continu- ously to carbo

Summary of the content on the page No. 18

2 Operational Theory Model 3000PA Nominal output in air is 0.19 mA, and 90 % response time is 45 s. Expected life in flue gas is 8 months. 2.2.6.3 Class B-1 Cell The class B-1 cell is for use in applications where it is exposed to less than 0.1 % of carbon dioxide, and where fast response is important. Nominal output in air is 0.50 mA, and 90 % response time is 7 s. Expected life in air is 8 months. 2.2.6.4 Class B-3 Cell The class B-3 cell is for use in applications where a slightly longe

Summary of the content on the page No. 19

Percent Oxygen Analyzer Operational Theory 2 mizes residual gas pockets that can interfere with very low level oxygen analysis. The sample system for the standard instrument incorporates ¼ inch tube fittings for sample inlet and outlet connections at the rear panel. For metric system installations, 6 mm adapters are supplied with each instrument. The sample or calibration gas flow through the system is monitored by a flow- meter downstream from the cell. Figure 2-4 shows the piping layout for

Summary of the content on the page No. 20

2 Operational Theory Model 3000PA Components in the shaded area are in Span In the -C option (internal control valves) only and are not shown in the piping diagram above. Zero In Cell Sample In Solenoid Valves In vacuum service the Flowmeter restrictor should be In normal service the placed here . restrictor should be placed here . Exhaust Out Restrictor Figure 2-5: Flow Diagram 2.4 Electronics and Signal Processing The Model 3000P Percent Oxygen Analyzer uses an 8031 microcon- trolle


Alternative user manuals
# User manual Category Download
1 Teledyne OT-3 User manual Oxygen Equipment 2
2 Teledyne 3000ZA-3X User manual Oxygen Equipment 2
3 Teledyne 3000TA User manual Oxygen Equipment 24
4 Teledyne OXYGEN DETECTOR 319R User manual Oxygen Equipment 3
5 Teledyne 3000ZA User manual Oxygen Equipment 1
6 Teledyne 3000TA-XL-EU User manual Oxygen Equipment 8
7 Teledyne 3010MB User manual Oxygen Equipment 5
8 Teledyne 311PC User manual Oxygen Equipment 6
9 Teledyne 3010TBC User manual Oxygen Equipment 1
10 Teledyne 310 User manual Oxygen Equipment 2
11 Teledyne 307WA User manual Oxygen Equipment 0
12 Teledyne 3110 User manual Oxygen Equipment 75
13 Teledyne 311-D User manual Oxygen Equipment 16
14 Teledyne 315 User manual Oxygen Equipment 2
15 Teledyne 3300PA User manual Oxygen Equipment 3
16 3M 8110S User manual Oxygen Equipment 1
17 3M 7187 User manual Oxygen Equipment 1
18 3M 8210PLUS User manual Oxygen Equipment 1
19 3M 8214 User manual Oxygen Equipment 0
20 3M 8210 User manual Oxygen Equipment 6