Invacare IRC5PO2 user manual

User manual for the device Invacare IRC5PO2

Device: Invacare IRC5PO2
Category: Oxygen Equipment
Manufacturer: Invacare
Size: 8.29 MB
Added : 3/16/2014
Number of pages: 88
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Invacare IRC5PO2. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Invacare IRC5PO2.

For your convenience

If looking through the Invacare IRC5PO2 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Invacare IRC5PO2 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Invacare IRC5PO2 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Invacare IRC5PO2 User manual - Online PDF
Advertisement
« Page 1 of 88 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Invacare IRC5PO2 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Invacare IRC5PO2. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Service Manual

Perfecto
2
Oxygen Concentrator
®
(HomeFill Compatible)
Model IRC5PO2 (Sensored)
Model IRC5P (Non-Sensored)
DEALER: Keep this manual. The procedures in this manual MUST be
performed by a qualified technician.
For more information regarding
Invacare products, parts, and services,
please visit www.invacare.com

Summary of the content on the page No. 2

 WARNING DO NOT OPERATE THIS EQUIPMENT WITHOUT FIRST READING AND UNDERSTANDING THIS MANUAL. IF YOU ARE UNABLE TO UNDERSTAND THE WARNINGS, CAUTIONS, AND INSTRUCTIONS, CONTACT INVACARE TECHNICAL SERVICES BEFORE ATTEMPTING TO USE THIS EQUIPMENT - OTHERWISE SERIOUS INJURY OR PROPERTY DAMAGE MAY RESULT.  WARNING Invacare products are specifically designed and manufactured for use in conjunction with Invacare accessories. Accessories designed by other manufacturers have not been tested by Inva

Summary of the content on the page No. 3

TABLE OF CONTENTS TABLE OF CONTENTS SPECIAL NOTES ................................................................................ 6 FEATURES ........................................................................................ 7 TYPICAL PRODUCT PARAMETERS .................................................... 8 SECTION 1—IMPORTANT SAFEGUARDS ..........................................10 Important Safeguards.........................................................................................

Summary of the content on the page No. 4

TABLE OF CONTENTS TABLE OF CONTENTS SECTION 10—CHECK VALVES ......................................................... 46 Replacing Check Valves...........................................................................................................................46 SECTION 11—REGULATOR .............................................................. 48 Replacing Regulator.............................................................................................................................

Summary of the content on the page No. 5

TABLE OF CONTENTS TABLE OF CONTENTS SECTION 23—LEAK TEST ................................................................76 Leak Test ....................................................................................................................................................76 4 Way Valve Function Test....................................................................................................................78 SECTION 24— ALARM TEST ................................................

Summary of the content on the page No. 6

SPECIAL NOTES SPECIAL NOTES Signal words are used in this manual and apply to hazards or unsafe practices which  could result in personal injury or property damage. Refer to the table below for  definitions of the signal words. SIGNAL WORD MEANING Danger indicates an imminently hazardous situation which, DANGER if not avoided, will result in death or serious injury. Warning indicates a potentially hazardous situation which, if WARNING not avoided, could result in death or serious injury. Cauti

Summary of the content on the page No. 7

FEATURES FEATURES FRONT VIEW Oxygen Purity Indicator Oxygen Outlet Lights / Fault and Power Indicator Lights (SensO2 Model Only) Flowmeter Circuit Breaker Power Switch Hour Meter ACCESSORIES (NOT SHOWN): PreciseR ™ Pediatric Humidifier/Flowmeter Accessory ‐ IRCPF16 X HomeFill home oxygen compressor ‐ IOH200 *NOTE: This outlet fitting is to be used only  for filling oxygen cylinders with the HomeFill  home oxygen compressor. The outlet fitting  does not affect concentrator performance.  Refer

Summary of the content on the page No. 8

TYPICAL PRODUCT PARAMETERS TYPICAL PRODUCT PARAMETERS Electrical Requirements: 120 VAC ± 10% (132 VAC/108 VAC), 60 Hz Rated Current Input: Perfecto 5: 3 A 2 Sound Level: Perfecto 5: 44 ± 2 dBA Average 2 Altitude: Perfecto 5 - Up to 6,000 ft. (1828 meters) above sea level with- 2 out degradation of concentration levels. From 6,000 ft. (1828 meters) to 13,129 ft. (4000 meters) below 90% efficiency. *Oxygen Output All IRC5PO2/IRC5P models 95.6% to 87% at 0.5 to 5 L/min Concentration Levels: Maxim

Summary of the content on the page No. 9

TYPICAL PRODUCT PARAMETERS Electrical: No extension cords. Placement: No closer than three inches from any wall, furniture, draperies, or similar surfaces. Tubing: 7 ft cannula with a maximum 50 ft of Crush-Proof Tubing (DO NOT pinch). Relative Humidity: 20 to 60% Time of Operation: Up to 24 hours per day. Recommended Storage and Shipping Temper- -20°F to 150°F (-29°C to 65°C), at 15-95% relative humidity. ature: *NOTE: Stated concentration levels achieved after initial warm‐up period (approxi

Summary of the content on the page No. 10

SECTION 1—IMPORTANT SAFEGUARDS SECTION 1—IMPORTANT SAFEGUARDS Important Safeguards In order to ensure the safe installation, assembly and operation of the Perfecto   2 concentrator these instructions MUST be followed. CAUTION “Caution: Federal law restricts this device to sale or rental by or on order of a physician,  or any other practitioner licensed by the law of the State in which he/she practices to use  or order the use of this device.”  DANGER The use of oxygen therapy requires that spe

Summary of the content on the page No. 11

SECTION 1—IMPORTANT SAFEGUARDS Radio Frequency Interference Most electronic equipment is influenced by Radio Frequency Interference (RFI). Caution  should be exercised with regard to the use of portable communications equipment in the  area around such equipment. To Reduce The Risk Of Burns, Electrocution, Fire Or Injury To Persons. DO NOT come in contact with the concentrator while wet. DO NOT place or store product where it can drop into water or other liquid. DO NOT reach for product that ha

Summary of the content on the page No. 12

SECTION 2—INSTALLATION/SEQUENCE OF OPERATION SECTION 2—INSTALLATION/ SEQUENCE OF OPERATION Verification of Battery Free Power Loss Alarm Check the Perfecto2 concentrator for proper operating conditions. 1. If the unit has been in below‐freezing temperatures, allow it to warm up to room  temperature before operating. 2. The concentrator may need to be turned on for four to five seconds to charge the  Battery Free Power Loss Alarm. Connect power cord to outlet and turn the  concentrator on. Turn f

Summary of the content on the page No. 13

SECTION 2—INSTALLATION/SEQUENCE OF OPERATION The electrical activation of the 4‐way Valve is accomplished every 8 to 15 seconds by the  pressure sensor and P.C. Board electronics when the pressure reaches a set point of 21  p.s.i. (144.79 kPa) output flows 4 L/min and above or 16 p.s.i. (110.32 kPa) output flows 3  L/min and below. The time between cycles is dependent on altitude, flow rate and  internal environmental factors. A P.E. valve opens just prior to the shift of the 4‐way valve. This a

Summary of the content on the page No. 14

SECTION 2—INSTALLATION/SEQUENCE OF OPERATION After five minutes, if the oxygen purity exceeds 85% ± 2%, the GREEN light will continue  to illuminate. If the oxygen level is not above 85% ± 2% after the first five minutes, the system will  continue to monitor the O  and wait for a maximum of 30 minutes from start‐up to reach  2 85% ± 2% before activating an alarm. Environmental factors such as low voltage, high  altitude, or age of the machine will affect the time required to reach 85% ± 2%.  If 

Summary of the content on the page No. 15

SECTION 3—PNEUMATIC DIAGRAM SECTION 3—PNEUMATIC DIAGRAM Perfecto2 Oxygen Concentrator Ouput Output HEPA Filter Check Flowmeter Valve Patient Output Oxygen Sensor Pressure (SensO models Only) Regulator 2 Pressure Sensor P.S.I. O 2 P.C. Board Product Tank Check Valves Air Inlet Cabinet Filter Compressor Inlet Filter Sieve Sieve P.E. Valve Bed Bed 4-way Valve Compressor Solenoid Pilot Relief Valve Exhaust Heat Muffler LEGEND Pneumatic Connections Electrical Connection

Summary of the content on the page No. 16

SECTION 4—TROUBLESHOOTING SECTION 4—TROUBLESHOOTING SYMPTOM PROBABLE CAUSE SOLUTION Normal Operation: No Problems. System Okay. Internal Status Indicators: RED: Off GREEN: Off Unit plugged in, power switch on. Single beep on start up. Power loss: No Problems. Battery Free Circuit drained. Plug in cord Internal Status Indicators: and turn power switch ON () to I/ RED: Off recharge. GREEN: Off Unit unplugged, power switch on, alarm off. Power loss: No power at outlet. Check electrical outlet

Summary of the content on the page No. 17

SECTION 4—TROUBLESHOOTING SYMPTOM PROBABLE CAUSE SOLUTION Power Loss: P.C. board. (Continued) a. P.C. board damaged. a. Replace P.C. Board. Refer to Internal Status Indicators: Replacing P.C. Board on page 58. RED: Off b. Loose or damaged connector. b. Repair or replace connector. GREEN: Off Unit plugged in, power switch, alarm off. Battery Free circuit drained Internal Power Transformer assembly. Loss Senso : a. Faulty. a. Replace. Refer to Replacing the 2 Transformer on page 61. Int

Summary of the content on the page No. 18

SECTION 4—TROUBLESHOOTING SYMPTOM PROBABLE CAUSE SOLUTION LOW PRESSURE: Compressor: Internal Status Indicators: a. Leaks at fittings or tubing a. Replace or repair. b. Leaking or defective relief valve. b. Repair leak or replace. RED: One Flash c. Insufficient voltage at outlet. c. DO NOT use extension cords. Use GREEN: One Flash another outlet. Or d. Rebuild top end of compressor. Refer d. Worn cup seals or gaskets. RED: One Flash to Rebuilding the Thomas Model GREEN: Three Flashes 2

Summary of the content on the page No. 19

SECTION 4—TROUBLESHOOTING SYMPTOM PROBABLE CAUSE SOLUTION Unit not operating: Alarm: P.C. board Failure. Replace P.C. board.Refer to Replacing P.C. On or Off Board on page 58. Internal Status Indicators: RED: Two Flashes GREEN: Four Flashes Or RED: Two Flashes GREEN: Five Flashes Low Concentration: NOTE: Cabinet filters dirty. Clean or replace. Refer to Cleaning the Check for O purity using a Cabinet Filter on page 24, Replacing the 2 Outlet HEPA Filter on page 25, and calibrated Oxygen An

Summary of the content on the page No. 20

SECTION 4—TROUBLESHOOTING SYMPTOM PROBABLE CAUSE SOLUTION Low Concentration P.C. board: Check pressure at product tank. Pressure (Continued) a. Shifts at wrong pressures. should rise to 21 p.s.i. at shift point. If not, replace P.C. Board. Refer to Replacing P.C. Board on page 58. Flowmeter: a. Flowmeter opened beyond a. Return flow to maximum setting. maximum flow rate. b. Cracked or broken fitting. b. Replace fitting. c. Input tubing leaking or loose. c. Repair or replace. Refer to R


Alternative user manuals
# User manual Category Download
1 Invacare 20EX User manual Oxygen Equipment 0
2 Invacare 212EX User manual Oxygen Equipment 0
3 Invacare 636959 User manual Oxygen Equipment 2
4 Invacare 10 User manual Oxygen Equipment 1
5 Invacare 1126360 3 User manual Oxygen Equipment 0
6 Invacare 10L User manual Oxygen Equipment 1
7 Invacare 50EX User manual Oxygen Equipment 0
8 Invacare 5 User manual Oxygen Equipment 13
9 Invacare ACC220 User manual Oxygen Equipment 0
10 Invacare CE0123 User manual Oxygen Equipment 0
11 Invacare HF2E540M9 User manual Oxygen Equipment 0
12 Invacare HF2PCM2KIT User manual Oxygen Equipment 0
13 Invacare 211EX User manual Oxygen Equipment 0
14 Invacare 1148114 User manual Oxygen Equipment 0
15 Invacare HF2POST9 User manual Oxygen Equipment 0
16 3M 8110S User manual Oxygen Equipment 1
17 3M 7187 User manual Oxygen Equipment 1
18 3M 8210PLUS User manual Oxygen Equipment 1
19 3M 8214 User manual Oxygen Equipment 0
20 3M 8210 User manual Oxygen Equipment 6