Invacare IRC5LXO2AW user manual

User manual for the device Invacare IRC5LXO2AW

Device: Invacare IRC5LXO2AW
Category: Oxygen Equipment
Manufacturer: Invacare
Size: 0.97 MB
Added : 3/16/2014
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Invacare IRC5LXO2AW. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Invacare IRC5LXO2AW.

For your convenience

If looking through the Invacare IRC5LXO2AW user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Invacare IRC5LXO2AW on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Invacare IRC5LXO2AW to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Invacare IRC5LXO2AW User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Invacare IRC5LXO2AW but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Invacare IRC5LXO2AW. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Operator's Manual

Platinum
Oxygen Concentrators Standard,
with ® ®
/SensO and HomeFill
2
Model IRC5LXAW
Model IRC5LXO2AW
Model IRC5LXO2AWQ
Model IRC9LXO2AWQ
Dealer: This manual must be given to the
end user.
User: Before using this concentrator, read
this manual and save for future reference.
For more information regarding
Invacare products, parts, and services,
please visit www.invacare.com
0434

Summary of the content on the page No. 2

WARNING  WARNING DO NOT USE THIS PRODUCT OR ANY AVAILABLE OPTIONAL EQUIPMENT WITHOUT FIRST COMPLETELY READING AND UNDERSTANDING THESE INSTRUCTIONS AND ANY ADDITIONAL INSTRUCTIONAL MATERIAL SUCH AS OWNER’S MANUALS, SERVICE MANUALS OR INSTRUCTION SHEETS SUPPLIED WITH THIS PRODUCT OR OPTIONAL EQUIPMENT. IF YOU ARE UNABLE TO UNDERSTAND THE WARNINGS, CAUTIONS OR INSTRUCTIONS, CONTACT A HEALTHCARE PROFESSIONAL, DEALER OR TECHNICAL PERSONNELBEFORE ATTEMPTING TO USE THIS EQUIPMENT - OTHERWI

Summary of the content on the page No. 3

TABLE OF CONTENTS TABLE OF CONTENTS SPECIAL NOTES ...............................................5 RECYCLING INFORMATION .............................6 SECTION 1—GENERAL GUIDELINES .....................7 Maintenance.......................................................................................... 9 Radio Frequency Interference.......................................................... 9 To Reduce The Risk Of Burns, Electrocution, Fire Or Injury To Persons ................................

Summary of the content on the page No. 4

TABLE OF CONTENTS Routine Maintenance........................................................................27 SECTION 7—TROUBLESHOOTING GUIDE ............31 LIMITED WARRANTY .................................... 33 ™ Platinum 4 Part No 1134866

Summary of the content on the page No. 5

SPECIAL NOTES SPECIAL NOTES Signal words are used in this manual and apply to hazards or  unsafe practices which could result in personal injury or  property damage. Refer to the following table for definitions  of the signal words. SIGNAL WORD MEANING Danger indicates an imminently hazardous situation which, if not avoided, will result in death or serious DANGER injury. Warning indicates a potentially hazardous situation which, if not avoided, could result in death or WARNING serious injury

Summary of the content on the page No. 6

RECYCLING INFORMATION RECYCLING INFORMATION This product has been supplied from an environmentally  aware manufacturer that complies with the Waste Electrical  and Electronic Equipment (WEEE) Directive 2002/96/CE. This product may contain substances that could be harmful to  the environment if disposed of in places (landfills) that are not  appropriate according to legislation. The ʹcrossed out wheelie binʹ symbol is placed on this product  to encourage you to recycle wherever possible. Please b

Summary of the content on the page No. 7

SECTION 1—GENERAL GUIDELINES SECTION 1—GENERAL GUIDELINES  WARNING SECTION 1 - GENERAL GUIDELINES contains important information for the safe operation and use of this product. In order to ensure the safe installation, assembly and  operation of the Platinum concentrator these instructions  MUST be followed. CAUTION “Caution: Federal law restricts this device to sale or rental by  or on order of a physician, or any other practitioner licensed  by the law of the governmental agency in which he

Summary of the content on the page No. 8

SECTION 1—GENERAL GUIDELINES  WARNINGS The use of oxygen therapy requires that special care be taken  to reduce the risk of fire. Any materials that will burn in air,  and some that will not, are easily ignited and burn rapidly in  high concentrations of oxygen. For safety concerns, it is  necessary that all sources of ignition be kept away from the  product and preferably out of the room in which it is being  used. NO SMOKING signs should be prominently displayed. A spontaneous and violent ign

Summary of the content on the page No. 9

SECTION 1—GENERAL GUIDELINES Fill humidifier with water to the level shown by the  manufacturer. DO NOT overfill. Keep unit at least 7.5 cm (3 in) away from walls, draperies,  furniture, and the like.  Invacare recommends that Crushproof oxygen tubing  (supplied by Invacare) be used with this product and NOT  exceed 15.2 m (50 ft) in length. Recommended use for  Platinum 9 is up to 15.2 m (50 ft) in length of high flow tubing. Maintenance The Invacare Oxygen Concentrator was specifically designe

Summary of the content on the page No. 10

SECTION 1—GENERAL GUIDELINES DO NOT reach for product that has fallen into water. Unplug  IMMEDIATELY. This device is to be used only in accordance with the  prescription of a physician and this Owners Manual. If at any  time the patient or attendant conclude that the patient is  receiving an insufficient amount of oxygen, the supplier  and/or physician should be contacted IMMEDIATELY. No  adjustments should be made to the flowrate unless prescribed  by a physician. Close supervision is necessar

Summary of the content on the page No. 11

SECTION 2—FEATURES SECTION 2—FEATURES FRONT VIEW Oxygen Purity and Fault Indicator Oxygen Outlet Lights (SensO model)/Fault and 2 Power Indicator Lights (LX model) Flowmeter Power Switch Circuit Breaker Elapsed Time Meter (Hour Meter) Cabinet Filter (one of two shown) *NOTE: This outlet fitting is to be used only for filling oxygen  cylinders with the HomeFill home oxygen compressor. The outlet  fitting does not affect concentrator performance. Refer to the  HomeFill ownerʹs manual, part num

Summary of the content on the page No. 12

SECTION 3—SHIPPING AND HANDLING SECTION 3—SHIPPING AND HANDLING NOTE: For this procedure, refer to  FIGURE 3.1 on page13. Before you install and operate the concentrator, please refer to  Platinum Series Ownerʹs Manual. The Platinum concentrator should ALWAYS be kept in the  upright position to prevent cabinet damage while being  transported. The shipping container has been designed to  assure maximum protection of the concentrator. If the concentrator is to be reshipped by common carrier, it 

Summary of the content on the page No. 13

SECTION 3—SHIPPING AND HANDLING FIGURE 3.1 Unpacking Part No 1134866 13 Platinum™

Summary of the content on the page No. 14

SECTION 4—TYPICAL PRODUCT PARAMETERS SECTION 4—TYPICAL PRODUCT PARAMETERS Regulatory EN/IEC 60601-1 Listing: Alternating Current Type BF equipment Unit running Unit not running Attention - Consider Accompanying Documents DO NOT smoke Class II, Double Insulation Electrical Requirements: 230 VAC ± 10% (253 VAC/207 VAC), 50 Hz Rated Current Input: 1.4 A (IRC5LXO2AWQ) 2.0 A (IRC5LXAW, IRC5LXO2AW) 2.1 A (IRC9LXO2AWQ) Sound Level: 39.5 dB Average (IRC5LXO2AWQ) 44 dB Average (IRC5LXAW, IRC5LXO2AW) 50

Summary of the content on the page No. 15

SECTION 4—TYPICAL PRODUCT PARAMETERS *Oxygen Output IRC5LXAW, IRC5LXO2AW and Concentration Levels: IRC5LXO2AWQ All 5LXO2AWQ/5LXAW/ 93% minimum at 1 to 3 L/min. 5LXO2AW/9LXO2AWQ 91% minimum at 4 L/min. models 87% minimum at 5 L/min. (maximum * (Stated concentration levels recommended flow) achieved after initial warm-up IRC9LXO2AWQ period (approximately 30 92% minimum at 1 to 2 L/min. minutes). 91% minimum at 8 L/min. 87% minimum at 9 L/min. 93% minimum at 3 to 7 L/min. Maximum Outlet Press

Summary of the content on the page No. 16

SECTION 4—TYPICAL PRODUCT PARAMETERS Change in maximum 0.7 L/min. recommended flow when back pressure of 7k Pa is applied: Filters: Cabinet (2), Outlet HEPA and Compressor Inlet. Safety System: Current overload or line surge shutdown. High temperature compressor shutdown. High Pressure Alarm w/compressor shutdown. Low Pressure Alarm w/compressor shutdown. Battery Free Power Loss Alarm. SensO Oxygen System (SensO Model) Low 2 2 Flow Alarm. Width: 46.7 cm ± 1 cm (18 3/8 in ± 3/8 in) He

Summary of the content on the page No. 17

SECTION 4—TYPICAL PRODUCT PARAMETERS Regulatory Listing: IRC5LXAW/IRC5LXO2AW/ IRC5LXO2AWQ/IRC9LXO2AWQ ETL tested as complying with: EN55011 EN61000-3-2 EN61000-3-3 IEC 60601-1, A1, A2 IEC 60601-1-2 IRC5LXO2AW, IRC5LXO2AWQ, IRC9LXO2AWQ Models Only ISO8359 MDD CE marked models: IRC5LXO2AW, IRC5LXO2AWQ, IRC9LXO2AWQ Electrical: No extension cords. Placement: No closer than 7.5 cm (3 inches) from any wall, furniture, draperies, or similar surfaces. Tubing: IRC5LXAW, IRC5LXO2AW, IRC5LXO2AWQ 2.1 m

Summary of the content on the page No. 18

SECTION 4—TYPICAL PRODUCT PARAMETERS SENSO INDICATORS 2 LABEL STATUS INDICATOR LIGHTS SYMBOL (LED) SYSTEM OKAY GREEN Indicator Light O over 85% (± 2%) O 2 2 O Between 73% (± 3%) YELLOW Indicator light 2 A. YELLOW Solid to 85% (±2%) B. YELLOW Flashing Sensor Failure Call a qualified technician. SYSTEM FAILURE RED Indicator Light O Below 73% (±3%) Refer to Troubleshooting Guide 2 on page 31. LX INDICATORS LABEL STATUS INDICATOR LIGHTS SYMBOL (LED) SYSTEM OKAY GREEN Indicator Light I/O SYSTEM F

Summary of the content on the page No. 19

SECTION 5—OPERATING INSTRUCTIONS SECTION 5—OPERATING INSTRUCTIONS Introduction Your oxygen concentrator is intended for individual use in the  home. It is an electronically operated device that separates  oxygen from room air. It provides high concentration of  oxygen directly to you through a nasal cannula. Clinical  studies have documented that oxygen concentrators are  therapeutically equivalent to other types of oxygen delivery  systems. Your provider will show you how to use your oxygen  c

Summary of the content on the page No. 20

SECTION 5—OPERATING INSTRUCTIONS Recommended Guidelines for Optimum Performance Temperature: (10°C - 35°C) 50°F - 95°F Electrical: No extension cords. Placement: No closer than 7.5 cm (3 in) from the wall, furniture, draperies, or similar surfaces. Tubing and Cannula: IRC5LXAW, IRC5LXO2AW, IRC5LXO2AWQ 2.1 m (7 ft) cannula with a maximum 15.2 m (50 ft) of Crush-Proof Tubing (DO NOT pinch). IRC9LXO2AWQ Recommended use up to 15.2 m (50 ft) high flow tubing with high flow cannula at all flow


Alternative user manuals
# User manual Category Download
1 Invacare 20EX User manual Oxygen Equipment 0
2 Invacare 212EX User manual Oxygen Equipment 0
3 Invacare 636959 User manual Oxygen Equipment 2
4 Invacare 10 User manual Oxygen Equipment 1
5 Invacare 1126360 3 User manual Oxygen Equipment 0
6 Invacare 10L User manual Oxygen Equipment 1
7 Invacare 50EX User manual Oxygen Equipment 0
8 Invacare 5 User manual Oxygen Equipment 13
9 Invacare ACC220 User manual Oxygen Equipment 0
10 Invacare CE0123 User manual Oxygen Equipment 0
11 Invacare HF2E540M9 User manual Oxygen Equipment 0
12 Invacare HF2PCM2KIT User manual Oxygen Equipment 0
13 Invacare 211EX User manual Oxygen Equipment 0
14 Invacare 1148114 User manual Oxygen Equipment 0
15 Invacare HF2POST9 User manual Oxygen Equipment 0
16 3M 8110S User manual Oxygen Equipment 1
17 3M 7187 User manual Oxygen Equipment 1
18 3M 8210PLUS User manual Oxygen Equipment 1
19 3M 8214 User manual Oxygen Equipment 0
20 3M 8210 User manual Oxygen Equipment 6