Invacare HF2E540M9 user manual

User manual for the device Invacare HF2E540M9

Device: Invacare HF2E540M9
Category: Oxygen Equipment
Manufacturer: Invacare
Size: 1.36 MB
Added : 8/28/2013
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Invacare HF2E540M9. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Invacare HF2E540M9.

For your convenience

If looking through the Invacare HF2E540M9 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Invacare HF2E540M9 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Invacare HF2E540M9 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Invacare HF2E540M9 User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Invacare HF2E540M9 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Invacare HF2E540M9. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Operator’s Manual
®
HomeFill Cylinder
Oxygen 540 Valve
HF2E540M9
“Caution: Federal law restricts this device to sale or 
rental by or on order of a physician, or any other 
practitioner licensed by the law of the State in which 
he/she practices to use or order the use of this device.”
Dealer: This manual MUST be given to the end
user.
User: Before using this cylinder, read this
manual and save for future reference.
For more information regarding
Invacare products, parts, and services,
plea

Summary of the content on the page No. 2

 WARNING DO NOT USE THIS PRODUCT OR ANY AVAILABLE OPTIONAL EQUIPMENT WITHOUT FIRST COMPLETELY READING AND UNDERSTANDING THESE INSTRUCTIONS AND ANY ADDITIONAL INSTRUCTIONAL MATERIAL SUCH AS OWNER’S MANUALS, SERVICE MANUALS OR INSTRUCTION SHEETS SUPPLIED WITH THIS PRODUCT OR OPTIONAL EQUIPMENT. IF YOU ARE UNABLE TO UNDERSTAND THE WARNINGS, CAUTIONS OR INSTRUCTIONS, CONTACT A HEALTHCARE PROFESSIONAL, DEALER OR TECHNICAL PERSONNEL BEFORE ATTEMPTING TO USE THIS EQUIPMENT - OTHERWISE, INJ

Summary of the content on the page No. 3

TABLE OF CONTENTS TABLE OF CONTENTS SPECIAL NOTES ...............................................4 RECEIVING INSPECTION ..................................4 INTENDED USE ................................................4 SECTION 1—GENERAL GUIDELINES ..................5 SECTION 2—FEATURES ....................................8 SECTION 3—TYPICAL PRODUCT PARAMETERS .................................................9 SECTION 4—INSPECTION AND COMPRESSOR INTERFACE .......................................

Summary of the content on the page No. 4

SPECIAL NOTES SPECIAL NOTES Signal words are used in this manual and apply to hazards or  unsafe practices which could result in personal injury or  property damage. Refer to the following table for definitions  of the signal words. SIGNAL WORD MEANING DANGER Danger indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING Warning indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury

Summary of the content on the page No. 5

SECTION 1—GENERAL GUIDELINES SECTION 1—GENERAL GUIDELINES  WARNING SECTION 1 - GENERAL GUIDELINES contains important information for the safe operation and use of this product.  DANGER This product is not intended as a life-sustaining or life-supporting device.  WARNING Only personnel instructed and trained in the use of the  HF2E540M9 Cylinder Assembly should operate this product. Product contains magnetic, ferrous material that may affect  the results of an MRI. Be sure all connections 

Summary of the content on the page No. 6

SECTION 1—GENERAL GUIDELINES  WARNING DO NOT attempt to repair product.  DO NOT immerse product in any kind of liquid.  Store product in a clean area when not in use.  Only use an Invacare Corporation HF2POST9BAG carrying  bag. NEVER smoke in an area where oxygen is being  administered. ALWAYS confirm prescribed dose before administering to  patient and monitor on a frequent basis. DO NOT use if dirt or contaminants are present on or around  cylinder, valve, product or connecting devices. NEVER

Summary of the content on the page No. 7

SECTION 1—GENERAL GUIDELINES  WARNING NEVER oil or lubricate the cylinder fittings. NEVER use any  penetrating oil or lubricant such as WD‐40 or 3 in One. If  connection difficulty is experienced verify that the cylinder  fitting is being inserted straight down into the compressor  coupler. If continued difficulty is experienced contact your  supplier for assistance. DO NOT allow cylinders to tip or fall. Secure gas cylinders so  they cannot fall. Ensure cylinder is always in upright position.

Summary of the content on the page No. 8

SECTION 2—FEATURES SECTION 2—FEATURES 540 Connection Port (with Protective Cap) Cylinder Cylinder Fill Valve Port FIGURE 2.1 Product Diagram ® HomeFill Cylinder 8 Part No 1163156

Summary of the content on the page No. 9

SECTION 3—TYPICAL PRODUCT PARAMETERS SECTION 3—TYPICAL PRODUCT PARAMETERS DIMENSIONS: Weight 5.1 lbs (2.31 kg) Overall Length 13.25 in (33.6 cm) Diameter 4.4 in (11.1 cm) STORAGE CONDITIONS TEMPERATURE: -40°F (-40°C) to 140°F (60°C) MAXIMUM HUMIDITY: 95% ® Part No 1163156 9 HomeFill Cylinder

Summary of the content on the page No. 10

SECTION 4—INSPECTION AND COMPRESSOR INTERFACE SECTION 4—INSPECTION AND COMPRESSOR INTERFACE ® NOTE: Refer to the HomeFill   Compressor Owner’s Manual for  compressor operating instructions. Cylinder Prefill Inspection  WARNING All cylinders MUST be inspected before attempting to fill; otherwise, injury or damage may occur. NEVER smoke in an area where oxygen is being administered. NEVER use near any type of flame or flammable/explosive substances, vapors or atmosphere. NOTE: For this proce

Summary of the content on the page No. 11

SECTION 4—INSPECTION AND COMPRESSOR INTERFACE External Examination 1. Examine the outside of the cylinder for the following  conditions and replace the cylinder if they exist: •Dents or dings •Arc burns •Oil or grease •Any other signs of damage that might cause a cylinder  to be unacceptable or unsafe for use. 2. Examine the cylinder for evidence of fire or thermal  damage. Evidence includes charring or blistering of the  paint, or other protective coating or heat sensitive  indicator. If fire o

Summary of the content on the page No. 12

SECTION 4—INSPECTION AND COMPRESSOR INTERFACE Checking Cylinder Pressure  WARNING NEVER use tools of any kind to connect/disconnect the cylinder and the compressor. Otherwise, severe injury and/or damage may occur. DO NOT drop oxygen cylinders. Use two hands when handling/transporting oxygen cylinders. Otherwise, injury or damage may occur. DO NOT use a liquid leak detector to test for leaks. NOTE: For this procedure, refer to FIGURE 4.1 on page13. 1. Install a conserver or regulator onto t

Summary of the content on the page No. 13

SECTION 4—INSPECTION AND COMPRESSOR INTERFACE Filling the Cylinder NOTE: For this procedure, refer to FIGURE 4.1 thru FIGURE 4.6. 1. Check the cylinder pressure before attempting to fill  cylinder. Refer to Checking Cylinder Pressure on page12. 2. Close the cylinder valve by rotating clockwise (FIGURE  4.1). 3. Remove the conserver or regulator according to the device  manufacturer instructions (FIGURE 4.1). CONSERVER/REGULATOR CONSERVER/REGULATOR INSTALLED REMOVED Conserver/ Regulator Cylinder

Summary of the content on the page No. 14

SECTION 4—INSPECTION AND COMPRESSOR INTERFACE Connector Post Valve Cover Fillport Cover FIGURE 4.2 Fillport Covers 5. On the compressor unit, momentarily push DOWN on the  outer ring (sleeve) of the connector fillport to reset the  connector (FIGURE 4.3). ® HomeFill Cylinder 14 Part No 1163156

Summary of the content on the page No. 15

SECTION 4—INSPECTION AND COMPRESSOR INTERFACE NOTE: If the outer ring (sleeve) is in the UP position (GREEN  dots not visible), the connector fillport will not be able to  accept the cylinder fillport. Pushing DOWN momentarily  will reset the connector fillport (GREEN dots visible) to  accept the cylinder fillport. PUSH Outer Ring (Sleeve) DOWN Connector Fillport GREEN Dots BEFORE COUPLING CYLINDER, PUSH DOWN ON SLEEVE UNTIL GREEN DOTS ARE VISIBLE. FIGURE 4.3 Resetting Connector Fillport 6.

Summary of the content on the page No. 16

SECTION 4—INSPECTION AND COMPRESSOR INTERFACE NOTE: Refer to Cylinder Fill Times on page20 for the length of time  it will take to fill the cylinder. DETAIL “B” DETAIL “A” Cylinder Cylinder Assembly Outer Ring Fillport (Sleeve) Compressor DETAIL “C” Power Switch Cylinder Outer Ring (Sleeve) Compressor Connector Cylinder PULL Cradle Fillport Fillport UP FIGURE 4.4 Connecting the Cylinder to the Compressor ® HomeFill Cylinder 16 Part No 1163156

Summary of the content on the page No. 17

SECTION 4—INSPECTION AND COMPRESSOR INTERFACE 11.After the cylinder is full, press the compressor power  switch to the Off (O) position (FIGURE 4.5). 12.Grasp the cylinder assembly (FIGURE 4.5). 13.With the other hand, grasp the outer ring (sleeve) of the  connector fillport and push DOWN (FIGURE 4.5). 14.Lift up on the cylinder assembly to remove from the  connector fillport (FIGURE 4.5). PUSH DOWN Outer Ring (Sleeve) Cylinder Cylinder Fillport Assembly Power Switch Connector Compressor Fi

Summary of the content on the page No. 18

SECTION 4—INSPECTION AND COMPRESSOR INTERFACE  WARNING The fillport cover on the connector fillport and the post valve fillport MUST be replaced after filling and whenever not in use. If either of the fillport covers are missing contact your healthcare provider before using. 17.Place the fillport covers onto the connector fillport (located  on the compressor) and post valve fillport (located on the  cylinder) (FIGURE 4.6). 18.Install a 540 post valve compatible conserver or regulator  accord

Summary of the content on the page No. 19

SECTION 5—MAINTENANCE SECTION 5—MAINTENANCE 1. After each use, clean exterior of the product with a dry, lint  free cloth only. 2. Store product in a clean area free from grease, oil, and  other sources of contamination. CAUTION DO NOT use cleaning solutions. DO NOT immerse product in any kind of liquid. All repairs MUST be done by Invacare Corporation. ® Part No 1163156 19 HomeFill Cylinder

Summary of the content on the page No. 20

SECTION 6—CYLINDER FILL TIMES SECTION 6—CYLINDER FILL TIMES NOTE: All filling times are approximate and may vary on  environmental conditions. * Cylinder Filling Concentrator Flow Rate to Times Patient: (Platinum 5 up to 2.5 L/min and Platinum 10 up to 5 L/min) NORMAL 2 hr 20 min MAXIMUM 2 hr 45 min Troubleshooting If post valve cylinder fails to function, try the following  solutions. If problem cannot be corrected, consult your  dealer/home care equipment provider. PROBLEM POSSIBLE CAUSE SOL


Alternative user manuals
# User manual Category Download
1 Invacare 20EX User manual Oxygen Equipment 0
2 Invacare 212EX User manual Oxygen Equipment 0
3 Invacare 636959 User manual Oxygen Equipment 2
4 Invacare 10 User manual Oxygen Equipment 1
5 Invacare 1126360 3 User manual Oxygen Equipment 0
6 Invacare 10L User manual Oxygen Equipment 1
7 Invacare 50EX User manual Oxygen Equipment 0
8 Invacare 5 User manual Oxygen Equipment 13
9 Invacare ACC220 User manual Oxygen Equipment 0
10 Invacare CE0123 User manual Oxygen Equipment 0
11 Invacare HF2PCM2KIT User manual Oxygen Equipment 0
12 Invacare 211EX User manual Oxygen Equipment 0
13 Invacare 1148114 User manual Oxygen Equipment 0
14 Invacare HF2POST9 User manual Oxygen Equipment 0
15 Invacare HF2POSTD User manual Oxygen Equipment 0
16 3M 8110S User manual Oxygen Equipment 1
17 3M 7187 User manual Oxygen Equipment 1
18 3M 8210PLUS User manual Oxygen Equipment 1
19 3M 8214 User manual Oxygen Equipment 0
20 3M 8210 User manual Oxygen Equipment 6