Graham Field JB0160-015B-220 user manual

User manual for the device Graham Field JB0160-015B-220

Device: Graham Field JB0160-015B-220
Category: Oxygen Equipment
Manufacturer: Graham Field
Size: 1.97 MB
Added : 8/28/2013
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Graham Field JB0160-015B-220. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Graham Field JB0160-015B-220.

For your convenience

If looking through the Graham Field JB0160-015B-220 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Graham Field JB0160-015B-220 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Graham Field JB0160-015B-220 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Graham Field JB0160-015B-220 User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Graham Field JB0160-015B-220 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Graham Field JB0160-015B-220. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Oxygen COnCentratOr
User ManUal

Model numbers JB0160-010B, JB0160-010,
JB0160-010B-220, JB0160-010-220
and
JB0160-015B, JB0160-015, JB0160-015B-220,
JB0160-015-220 with O sensor
2
Important: Do not operate this concentrator without
first reading and understanding this manual!
save this manual for future use.

Summary of the content on the page No. 2

COntents 1 safety ................................................................................... 3 ImportantInformation .................................................................. 3 BeforeInstallation ......................................................................... 3 Placement ...................................................................................... 4 fireW arning& explosion ............................................................. 4 Maintenanc

Summary of the content on the page No. 3

Federal Law (USA) restricts this device to sale by or on the order of a physician. This product should not be used unless the operator has been instructed by a qualified health care professional. WARNING: Users who require continuous oxygenation must plan for alternate reserve sources of power and oxygen in the event of a failure or loss of power and oxygen. This device is to be used ONLY as an oxygen supplement device and is NOT intended to be a life- supporting or life-sustaining dev

Summary of the content on the page No. 4

Damage: If the electrical power source becomes s unstable, discontinue use and find an alternate source. Damage: The oxygen concentrator cabinet contains no s serviceable parts! The oxygen concentrator cabinet should ONLY be opened by an authorized equipment provider. Placement ATTENTION: The oxygen concentrator is intended to be rolled from room to room. Do not place the oxygen concentrator in surroundings where its airflow is obstructed. ATTENTION: Be certain to place the unit so that

Summary of the content on the page No. 5

WARNING: To reduce the risk of fire, special care must be taken when using oxygen concentrators. DO NOT SMOKE while using this device. Keep all matches, lighted cigarettes or other sources of ignition out of the room in which this concentrator is located. In public settings or when used in hospital or long-term care environments, prominently display NO SMOKING signs. WARNING: Textiles and other materials that normally would not easily burn, can ignite and burn with great intensity i

Summary of the content on the page No. 6

additional safetyW arnings WARNING: TO REDUCE THE RISK OF BURNS, ELECTROCUTION, FIRE OR INJURY TO PERSONS, avoid using while bathing. If continuous usage is required by the direction of a physician, the concentrator must be located in another room at least 9 feet (2.8m) from the bath. WARNING: DO NOT reach for a concentrator that has fallen into water. UNPLUG IT IMMEDIATELY. WARNING: In certain circumstances, oxygen therapy can be hazardous. Graham-Field recommends that you seek

Summary of the content on the page No. 7

ATTENTION: ALWAYS supervise closely when this product is used near children or those who require close supervision. ATTENTION: Only use this device as intended and described in this manual. ATTENTION: DO NOT use parts, accessories or adapters other than those authorized by manufacturer. ATTENTION: DO NOT connect the concentrator in parallel or series with other oxygen concentrators or oxygen therapy devices. ATTENTION: JB0160-015B, JB0160-015, JB0160-015B-220 and JB0160-015-220 only: Disc

Summary of the content on the page No. 8

 featuRes summary The John Bunn O Premier oxygen concentrator is intend- 2 ed for use as an oxygen supplement device in a home or care facility. Use the concentrator only as prescribed by a physician. The concentrator separates oxygen from ambient air, providing the user a high concentration of oxygen. Oxygen concentrator usage is therapeutically equivalent to other types of oxygen delivery systems. Characteristics • Reliable, safe, complete plastic outer shell. • Display screen shows tot

Summary of the content on the page No. 9

3 HandlIng gf Health Products,Inc. freight Policy for y our Protection, ReadCar efully The carrier accepted this merchandise “in good condition” and is responsible for safe delivery. Before signing the freight bill, inspect the shipment care- fully for damage or missing pieces. Apparent Loss or Damage Should visual inspection show loss or damage, this MUST be noted on the freight bill and signed by the carrier’s agent. Failure to do so may result in the carrier failing to honor the c

Summary of the content on the page No. 10

Inspection Examine exterior of the oxygen concentrator for nicks, dents, scratches or other damages. Inspect all compo- nents. storage Store the repackaged oxygen concentrator in a dry area. DO NOT place anything on top of the repackaged concen- trator. 10 JohnBunn O Pr  emierOxygen Concentrator

Summary of the content on the page No. 11

4 OPeRatIOn and InstallatIOn Preparing the Concentrator (referto above picture) 1. Unscrew the humidifier bottle cover, if so equipped (hu- midifier bottle is optional). 2. Fill the humidifier bottle with purified water (or dis- tilled water) between the maximum and minimum water level lines. If needed, add medication to the water, as prescribed by physician. 3. Screw the cover back on the humidifier bottle. 4. Screw the humidifier bottle adapter into the humidifier bottle cover. 5. Inser

Summary of the content on the page No. 12

trator’s AC connector into a properly grounded power outlet. t urning the Concentrator On 1. Press the power switch to start the concentrator. There will be a brief delay before the concentrator starts. The alarm system emits a tone of one second duration, the word HELLO appears on the hour meter LED panel, and the green power indicator light illuminates. ATTENTION: Every time the concentrator starts, the alarm system performs a self test, and emits a brief tone. If the alarm does anythin

Summary of the content on the page No. 13

5 MaIntenanCe Cleaningthe Cabinet Clean the cabinet at least once a month. 1. Turn off the power switch. 2. Clean the cabinet with a mild household cleaner and a non-abrasive cloth or sponge. Do not spill liquid inside the cabinet. Cleaning orReplacing the filters (3 t ypes) Clean or replace the filters as often as specified in the following paragraphs in order to protect the compressor and extend the concentrator’s life. Replacement filters are available from your Graham-Field eq

Summary of the content on the page No. 14

Side filters Note:For earlier models only ,you willneed a smallblade screwdriver to openthe side filter access door. Forlater models,the filter grill simply pulls out. Ifthis operation istoo dif ficult foryou to perform, please contact your equipmentprovider to perform thisfor you. Clean the side filters weekly. There are two side filters, one located on each side of the concentrator cabinet. Perform the following steps on both side filte

Summary of the content on the page No. 15

• A wood stove is used • Kerosene or oil is used • Pets are present • Tobacco is used Intake filter Note: Please haveyour Graham-Field equipment provider replace theintake filter .This operation requires openingthe intake filter accessdoor . Replace, do not clean, the intake filter annually (or more often, if the intake filter turns black). The frequency of re- placement depends on usage and condition of the environ- ment where the concentrator is used. Cleaning the Optio

Summary of the content on the page No. 16

6 tROuBlesHOOtIng guIde syMPtOM CHeCK / aCtIOn Concentrator poweris Checkif concentrator is unplugged; plug in. onand alarm is on, but concentrator doesn’t Check if circuit breaker is tripped; fix circuit work breaker. Ifconcentrator still doesn’twork, contact graham-fieldequipment pr ovider. syMPtOM CHeCK / aCtIOn Concentratorworks, Inspect tubes and cannula to ensure thatthey ar e butlittle or no oxygen notkink

Summary of the content on the page No. 17

syMPtOM CHeCK/ aCtIOn Concentratordoesn’ t discontinue use;contact graham-fieldequipment work;alarm sounds; provider immediately. Oxygenconcentration is too optional O sensor red lowfor safe use.  warninglight illuminates (JB0160-015B, JB0160-015, JB0160-015B- 0,  JB0160-015-0only) Note: Ifyou experience a problem withyour concentrator andare unable to serviceit yourself,contact the equipmentprovider fro

Summary of the content on the page No. 18

7 BIll Of MateRIals Your concentrator includes the following components: • Oxygen concentrator (one each) • User manual (one each) • Humidifier bottle hose (one each) • Humidifier bottle adapter (one each) The concentrator comes with one bottom filter, two side filters, and one intake filter already installed; Model Nos. JB0160-015B, JB0160-015, JB0160-015B-220 and JB0160-015-220 come with one O sensor already installed. 2 Replacement Partsand Optional accessories Replacement parts and o

Summary of the content on the page No. 19

8 sPeCIfICatIOns • Flow Range: 1 to 5L/min • Oxygen Concentration: 1-4 LPM 94% ± 2% 5 LPM 92% ± 2% • Maximum Outlet Pressure: 6.52 psi ± .065 psi (45kPa ± 4.5kPa) • Pressure Relief Mechanism Operational at: 36.26 psi ± 3.63 psi (250kPa ± 25kPa) • Altitude: Up to 5,997 feet (1,828 meters) above sea level without degradation of concentration levels. Efficiency of 90% from 5,997 to 13,123 feet (1,828 to 4,000 meters) above sea level. • Sound Level: ≤ 55dB • Power Supply: JB0160-010B, JB0160

Summary of the content on the page No. 20

9 lIMItedW aRRanty This warranty is extended only to the original purchaser of our products. This warranty gives you specific legal rights and you may also have other legal rights which may vary from state to state. GF Health Products, Inc. warrants its John Bunn O2 Premier Oxygen Concentrator to be free from defects in materials and workmanship from the date of pur- chase for the following time period: Compressor: six (6) years Balance of concentrator: five (5) years Removal of the


Alternative user manuals
# User manual Category Download
1 Graham Field JB0160-010B User manual Oxygen Equipment 0
2 Graham Field JB0160-015 User manual Oxygen Equipment 1
3 Graham Field JB0160-010B-220 User manual Oxygen Equipment 1
4 Graham Field JB0160-010 User manual Oxygen Equipment 0
5 Graham Field JB0160-015-220 User manual Oxygen Equipment 0
6 Graham Field JB0160-015B User manual Oxygen Equipment 0
7 Graham Field JOHN BUNN JB0150-081 User manual Oxygen Equipment 0
8 Graham Field JOHN BUNN JB0150-083 User manual Oxygen Equipment 0
9 Graham Field JOHN BUNN JB0150-086 User manual Oxygen Equipment 0
10 Graham Field JB0160-010-220 User manual Oxygen Equipment 0
11 Graham Field JOHN BUNN JB0150-085 User manual Oxygen Equipment 1
12 3M 8110S User manual Oxygen Equipment 1
13 3M 7187 User manual Oxygen Equipment 1
14 3M 8210PLUS User manual Oxygen Equipment 1
15 3M 8214 User manual Oxygen Equipment 0
16 3M 8210 User manual Oxygen Equipment 6